These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
677 related articles for article (PubMed ID: 27087560)
1. In Vitro Evaluation of Inflow Cannula Fixation Techniques in Left Ventricular Assist Device Surgery. Hanke JS; Krabatsch T; Rojas SV; Deniz E; Ismail I; Martens A; Shrestha M; Haverich A; Netuka I; Schmitto JD Artif Organs; 2017 Mar; 41(3):272-275. PubMed ID: 27087560 [TBL] [Abstract][Full Text] [Related]
2. Technique for insertion of HeartMate II left ventricular assist device inflow cannula. Soleimani B; Stephenson ER; Pae WE Ann Thorac Surg; 2011 Jun; 91(6):2001-2. PubMed ID: 21620010 [TBL] [Abstract][Full Text] [Related]
3. Technique for insertion of the inflow cannula of the INCOR left ventricular assist device. Komoda T; Weng Y; Hetzer R Ann Thorac Surg; 2008 Apr; 85(4):1466-7. PubMed ID: 18355562 [TBL] [Abstract][Full Text] [Related]
4. A modified suturing technique for the implantation of the apical cannula of the HeartMate II left ventricular assist device. Charitos EI; Sievers HH Interact Cardiovasc Thorac Surg; 2010 Oct; 11(4):393-4. PubMed ID: 20643820 [TBL] [Abstract][Full Text] [Related]
5. Proposing a novel technique to exclude the left ventricle with an assist device: insights from 4-dimensional flow magnetic resonance imaging. Klotz S; Meyer-Saraei R; Frydrychowicz A; Scharfschwerdt M; Putman LM; Halder S; Sievers HH Eur J Cardiothorac Surg; 2016 Sep; 50(3):439-45. PubMed ID: 27107046 [TBL] [Abstract][Full Text] [Related]
6. Implantation technique for the DuraHeart left ventricular assist system. Komoda T; Weng Y; Nojiri C; Hetzer R J Artif Organs; 2007; 10(2):124-7. PubMed ID: 17574518 [TBL] [Abstract][Full Text] [Related]
7. Titanium Fastener Utilization During HeartMate 3 Left Ventricular Assist Device Implantation. Johnson CA; Melvin AL; Robinson DA; Amirjamshidi H; Knight PA; Gosev I Innovations (Phila); 2018; 13(5):361-364. PubMed ID: 30394954 [TBL] [Abstract][Full Text] [Related]
8. Reducing regional flow stasis and improving intraventricular hemodynamics with a tipless inflow cannula design: An in vitro flow visualization study using the EVAHEART LVAD. May-Newman K; Montes R; Campos J; Marquez-Maya N; Vu V; Zebrowski E; Motomura T; Benkowski R Artif Organs; 2019 Sep; 43(9):834-848. PubMed ID: 31038753 [TBL] [Abstract][Full Text] [Related]
9. Novel Modification of HeartMate 3 Implantation. Wilson HK; Haithcock BE; Caranasos TG Ann Thorac Surg; 2021 Feb; 111(2):e133-e134. PubMed ID: 32949610 [TBL] [Abstract][Full Text] [Related]
10. Left Ventricular Assist Device Inflow Cannula Angle and Thrombosis Risk. Chivukula VK; Beckman JA; Prisco AR; Dardas T; Lin S; Smith JW; Mokadam NA; Aliseda A; Mahr C Circ Heart Fail; 2018 Apr; 11(4):e004325. PubMed ID: 29666072 [TBL] [Abstract][Full Text] [Related]
11. Intraventricular pledgetted sutures to prevent suction events in patients with the heartware left ventricular assist device. Saeed D; Maxhera B; Lichtenberg A; Albert A Ann Thorac Surg; 2014 Aug; 98(2):746-7. PubMed ID: 25087814 [TBL] [Abstract][Full Text] [Related]
12. Left ventricular assist device implantation in patients after left ventricular reconstruction. Palmen M; Braun J; Beeres SL; Klautz RJ Interact Cardiovasc Thorac Surg; 2016 Dec; 23(6):979-981. PubMed ID: 27481683 [TBL] [Abstract][Full Text] [Related]
13. Principles of HeartMate II implantation to avoid pump malposition and migration. Adamson RM; Mangi AA; Kormos RL; Farrar DJ; Dembitsky WP J Card Surg; 2015 Mar; 30(3):296-9. PubMed ID: 25472467 [TBL] [Abstract][Full Text] [Related]
14. Utility of cardiac computed tomography for inflow cannula patency assessment and prediction of clinical outcome in patients with the HeartMate II left ventricular assist device. Sacks J; Gonzalez-Stawinski GV; Hall S; Lima B; MacHannaford J; Dockery W; Cura M; Chamogeorgakis T Interact Cardiovasc Thorac Surg; 2015 Nov; 21(5):590-3. PubMed ID: 26223857 [TBL] [Abstract][Full Text] [Related]
15. A modified explant technique of HeartWare ventricular assist device for bridge to recovery. Shudo Y; Choi CW; Woo YJ; Ha RV Eur J Cardiothorac Surg; 2017 Dec; 52(6):1223-1224. PubMed ID: 28950296 [TBL] [Abstract][Full Text] [Related]
16. Association of Inflow Cannula Position with Left Ventricular Unloading and Clinical Outcomes in Patients with HeartMate II Left Ventricular Assist Device. Imamura T; Nguyen A; Chung B; Rodgers D; Sarswat N; Kim G; Raikhelkar J; Adatya S; Ota T; Song T; Juricek C; Estep JD; Burkhoff D; Jeevanandam V; Sayer G; Uriel N ASAIO J; 2019; 65(4):331-335. PubMed ID: 29933250 [TBL] [Abstract][Full Text] [Related]
17. Effect of Ventricular Arrhythmia Ablation in Patients With Heart Mate II Left Ventricular Assist Devices: An Evaluation of Ablation Therapy. Snipelisky D; Reddy YN; Manocha K; Patel A; Dunlay SM; Friedman PA; Munger TM; Asirvatham SJ; Packer DL; Cha YM; Kapa S; Brady PA; Noseworthy PA; Maleszewski JJ; Mulpuru SK J Cardiovasc Electrophysiol; 2017 Jan; 28(1):68-77. PubMed ID: 27766717 [TBL] [Abstract][Full Text] [Related]
18. Fine-tuning management of the Heart Assist 5 left ventricular assist device with two- and three-dimensional echocardiography. Demirozu ZT; Arat N; Kucukaksu DS Cardiovasc J Afr; 2016; 27(4):208-212. PubMed ID: 27841907 [TBL] [Abstract][Full Text] [Related]
19. A 3D printed exoskeleton facilitates HeartMate III inflow cannula position. Barabás IJ; Hartyánszky I; Kocher A; Merkely B Interact Cardiovasc Thorac Surg; 2019 Oct; 29(4):644-646. PubMed ID: 31230073 [TBL] [Abstract][Full Text] [Related]
20. Thrombus on the inflow cannula of the HeartWare HVAD: an update. Glass CH; Christakis A; Fishbein GA; Watkins JC; Strickland KC; Mitchell RN; Padera RF Cardiovasc Pathol; 2019; 38():14-20. PubMed ID: 30399526 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]