110 related articles for article (PubMed ID: 2709134)
1. A variation of transmission electron microscope sample preparation for VLSI analysis.
Madden MC; Crafard P
J Electron Microsc Tech; 1989 Feb; 11(2):161-6. PubMed ID: 2709134
[TBL] [Abstract][Full Text] [Related]
2. The focused ion beam fold-out: sample preparation method for transmission electron microscopy.
Floresca HC; Jeon J; Wang JG; Kim MJ
Microsc Microanal; 2009 Dec; 15(6):558-63. PubMed ID: 19804654
[TBL] [Abstract][Full Text] [Related]
3. Novel method for the plan-view TEM preparation of thin samples on brittle substrates by mechanical and ion beam thinning.
Sáfrán G; Grenet T
Microsc Res Tech; 2002 Feb; 56(4):308-14. PubMed ID: 11877808
[TBL] [Abstract][Full Text] [Related]
4. Preparation of cross-sectional transmission electron microscopy samples by electron beam lithography and reactive ion etching.
Wetzel JT
J Electron Microsc Tech; 1989 Jan; 11(1):62-9. PubMed ID: 2915262
[TBL] [Abstract][Full Text] [Related]
5. Preparation of cross-sectional TEM samples for low-angle ion milling.
McCaffrey JP; Barna A
Microsc Res Tech; 1997 Mar; 36(5):362-7. PubMed ID: 9140935
[TBL] [Abstract][Full Text] [Related]
6. InP sample preparation for the TEM by photochemical etching, ion milling, and chemical thinning.
Lowes TD; Cassidy DT
Microsc Res Tech; 1992 Nov; 23(3):252-9. PubMed ID: 1472754
[TBL] [Abstract][Full Text] [Related]
7. Influence of material properties on TEM specimen preparation of thin films.
Madsen LD; Weaver L; Jacobsen SN
Microsc Res Tech; 1997 Mar; 36(5):354-61. PubMed ID: 9140934
[TBL] [Abstract][Full Text] [Related]
8. Comparison of TEM specimen preparation of perovskite thin films by tripod polishing and conventional ion milling.
Eberg E; Monsen AF; Tybell T; van Helvoort AT; Holmestad R
J Electron Microsc (Tokyo); 2008 Dec; 57(6):175-9. PubMed ID: 18815212
[TBL] [Abstract][Full Text] [Related]
9. Selected area polishing for precision TEM sample preparation.
Liu JB; Tracy BM; Gronsky R
Microsc Res Tech; 1993 Oct; 26(2):162-6. PubMed ID: 8241552
[TBL] [Abstract][Full Text] [Related]
10. Optimized pre-thinning procedures of ion-beam thinning for TEM sample preparation by magnetorheological polishing.
Luo H; Yin S; Zhang G; Liu C; Tang Q; Guo M
Ultramicroscopy; 2017 Oct; 181():165-172. PubMed ID: 28578300
[TBL] [Abstract][Full Text] [Related]
11. A high-throughput approach for cross-sectional transmission electron microscopy sample preparation of thin films.
Yao B; Coffey KR
J Electron Microsc (Tokyo); 2008 Dec; 57(6):189-94. PubMed ID: 18984643
[TBL] [Abstract][Full Text] [Related]
12. Preparation of cross-sectional specimens of ceramic thermal barrier coatings for transmission electron microscopy.
Unal O; Heuer AH; Mitchell TE
J Electron Microsc Tech; 1990 Apr; 14(4):307-12. PubMed ID: 2332805
[TBL] [Abstract][Full Text] [Related]
13. Combining FIB milling and conventional Argon ion milling techniques to prepare high-quality site-specific TEM samples for quantitative EELS analysis of oxygen in molten iron.
Miyajima N; Holzapfel C; Asahara Y; Dubrovinsky L; Frost DJ; Rubie DC; Drechsler M; Niwa K; Ichihara M; Yagi T
J Microsc; 2010 Jun; 238(3):200-9. PubMed ID: 20579258
[TBL] [Abstract][Full Text] [Related]
14. Improved sample preparation for cross-sectional transmission electron microscopy of layered structures using rocking-angle ion-milling techniques.
Lee JS; Jeong YW; Kim ST
Microsc Res Tech; 1996 Apr; 33(6):490-5. PubMed ID: 8800754
[TBL] [Abstract][Full Text] [Related]
15. Preparation of TEM foils from Nb-10 a/o Si.
Cockeram B; Jackson AG; Omlor RE; Srinivasan R; Weiss I
Microsc Res Tech; 1992 Aug; 22(3):298-300. PubMed ID: 1504356
[TBL] [Abstract][Full Text] [Related]
16. Sample preparation technique for cross-sectional transmission electron microscopy of quantum wire structures.
Chen YP; Reed JD; O'Keefe SS; Schaff WJ; Eastman LF
Microsc Res Tech; 1993 Oct; 26(2):157-61. PubMed ID: 8241551
[TBL] [Abstract][Full Text] [Related]
17. The advanced ion-milling method for preparation of thin film using ion slicer: application to a sample recovered from diamond-anvil cell.
Tateno S; Sinmyo R; Hirose K; Nishioka H
Rev Sci Instrum; 2009 Jan; 80(1):013901. PubMed ID: 19191441
[TBL] [Abstract][Full Text] [Related]
18. Focused ion beam sectioning and lift-out method for copper and resist vias in organic low-k dielectrics.
Crawford EJ; Gignac L; Barth K; Petrus J; Levine E
Microsc Microanal; 2002 Dec; 8(6):502-8. PubMed ID: 12533211
[TBL] [Abstract][Full Text] [Related]
19. Thin foil preparation of metal particles in brittle ceramic matrices.
Yang CW; Williams DB; Goldstein JI
Microsc Res Tech; 1996 Nov; 35(4):334-9. PubMed ID: 8987027
[TBL] [Abstract][Full Text] [Related]
20. Controlled-depth and cross-section preparation techniques for transmission electron microscopy subsurface studies in metals.
Garcia-Borquez A; Kesternich W
Microsc Res Tech; 1993 Jun; 25(3):255-63. PubMed ID: 8400425
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]