These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 27096119)

  • 1. Gauge Blocks - A Zombie Technology.
    Doiron T
    J Res Natl Inst Stand Technol; 2008; 113(3):175-84. PubMed ID: 27096119
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Air Flow Rate as a Test For Gage Block Wringing.
    Guildner LA; Anderson RL; Edsinger RE
    J Res Natl Bur Stand A Phys Chem; 1973; 77A(5):667-670. PubMed ID: 32189760
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Precise interferometric length and phase-change measurement of gauge blocks based on reproducible wringing.
    Titov A; Malinovsky I; Belaïdi H; França RS; Massone CA
    Appl Opt; 2000 Feb; 39(4):526-38. PubMed ID: 18337922
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Toward subnanometer uncertainty in interferometric length measurements of short gauge blocks.
    Malinovsky I; Titov A; Dutra JA; Belaïdi H; França Rdos S; Massone CA
    Appl Opt; 1999 Jan; 38(1):101-12. PubMed ID: 18305592
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Gas Pressure Scale Based on Primary Standard Piston Gauges.
    Olson DA; Driver RG; Bowers WJ
    J Res Natl Inst Stand Technol; 2010; 115(6):393-412. PubMed ID: 27134793
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Scale-Mark-Based Gauge Reading for Gauge Sensors in Real Environments with Light and Perspective Distortions.
    Wang CH; Huang KK; Chang RI; Huang CK
    Sensors (Basel); 2022 Oct; 22(19):. PubMed ID: 36236588
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Phase topography-based characterization of thermal effects on materials and joining techniques.
    Lorenz H; Beckert E; Schödel R
    Appl Opt; 2015 Mar; 54(8):2046-56. PubMed ID: 25968382
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ring interferometer for two-sided measurement of the absolute lengths of end standards.
    Khavinson VM
    Appl Opt; 1999 Jan; 38(1):126-35. PubMed ID: 18305595
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Institutional obstacles to expansion of world food production.
    Crosson PR
    Science; 1975 May; 188(4188):519-24. PubMed ID: 17740002
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fibre optic Bragg grating sensors: an alternative method to strain gauges for measuring deformation in bone.
    Fresvig T; Ludvigsen P; Steen H; Reikerås O
    Med Eng Phys; 2008 Jan; 30(1):104-8. PubMed ID: 17369073
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characterization of Distributed Microfabricated Strain Gauges on Stretchable Sensor Networks for Structural Applications.
    Chen X; Topac T; Smith W; Ladpli P; Liu C; Chang FK
    Sensors (Basel); 2018 Sep; 18(10):. PubMed ID: 30274158
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 20 °C-A Short History of the Standard Reference Temperature for Industrial Dimensional Measurements.
    Doiron T
    J Res Natl Inst Stand Technol; 2007; 112(1):1-23. PubMed ID: 27110451
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An Intercomparison of Pressure Standards Between the Istituto di Metrologia "G. Colonnetti" and the National Bureau of Standards.
    Houck JC; Molinar GF; Maghenzani R
    J Res Natl Bur Stand (1977); 1983; 88(4):253-259. PubMed ID: 34566105
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development and performance characterization of a new standard mercury manometer.
    Akram HM; Maqsood M; Rashid H
    Rev Sci Instrum; 2007 Jul; 78(7):075101. PubMed ID: 17672787
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Foil Strain Gauges Using Piezoresistive Carbon Nanotube Yarn: Fabrication and Calibration.
    Abot JL; Góngora-Rubio MR; Anike JC; Kiyono CY; Mello LAM; Cardoso VF; Rosa RLS; Kuebler DA; Brodeur GE; Alotaibi AH; Coene MP; Coene LM; Jean E; Santiago RC; Oliveira FHA; Rangel R; Thomas GP; Belay K; da Silva LW; Moura RT; Seabra AC; Silva ECN
    Sensors (Basel); 2018 Feb; 18(2):. PubMed ID: 29401745
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A long-term in vivo bone strain measurement device.
    Szivek JA; Magee FP
    J Invest Surg; 1989; 2(2):195-206. PubMed ID: 2487248
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Needle size for vaccination procedures in children and adolescents.
    Beirne PV; Hennessy S; Cadogan SL; Shiely F; Fitzgerald T; MacLeod F
    Cochrane Database Syst Rev; 2015 Jun; (6):CD010720. PubMed ID: 26086647
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Long-term stability and performance characteristics of crystal quartz gauge at high pressures and temperatures.
    Matsumoto N; Sudo Y; Sinha BK; Niwa M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2000; 47(2):346-54. PubMed ID: 18238549
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A New Input Device for Spastics Based on Strain Gauge.
    Buchhold N; Baumgartner C
    Sensors (Basel); 2017 Apr; 17(4):. PubMed ID: 28420175
    [TBL] [Abstract][Full Text] [Related]  

  • 20.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.