These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

273 related articles for article (PubMed ID: 2709658)

  • 21. Hemodiafiltration using readily available equipment.
    Kohnle W; Sprenger K; Spohn B; Franz HE
    J Dial; 1979; 3(1):27-39. PubMed ID: 381340
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effects of novel manufacturing technology on blood and dialysate flow distribution in a new low flux "alpha Polysulfone" hemodialyzer.
    Gastaldon F; Brendolan A; Crepaldi C; Frisone P; Zamboni S; d'Intini V; Poulin S; Hector R; Granziero A; Martins K; Gellert R; Inguaggiato P; Ronco C
    Int J Artif Organs; 2003 Feb; 26(2):105-12. PubMed ID: 12653343
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Increasing dialysate flow rate increases dialyzer urea clearance and dialysis efficiency: an in vivo study.
    Azar AT
    Saudi J Kidney Dis Transpl; 2009 Nov; 20(6):1023-9. PubMed ID: 19861865
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of increasing dialysate flow rate on diffusive mass transfer of urea, phosphate and beta2-microglobulin during clinical haemodialysis.
    Bhimani JP; Ouseph R; Ward RA
    Nephrol Dial Transplant; 2010 Dec; 25(12):3990-5. PubMed ID: 20543211
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Impact of convective transport on dialyzer clearance.
    Galach M; Ciechanowska A; Sabalińska S; Waniewski J; Wójcicki J; Weryńskis A
    J Artif Organs; 2003; 6(1):42-8. PubMed ID: 14598124
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The clearance of protein-bound solutes by hemofiltration and hemodiafiltration.
    Meyer TW; Walther JL; Pagtalunan ME; Martinez AW; Torkamani A; Fong PD; Recht NS; Robertson CR; Hostetter TH
    Kidney Int; 2005 Aug; 68(2):867-77. PubMed ID: 16014068
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Blood and dialysate flow distributions in hollow-fiber hemodialyzers analyzed by computerized helical scanning technique.
    Ronco C; Brendolan A; Crepaldi C; Rodighiero M; Scabardi M
    J Am Soc Nephrol; 2002 Jan; 13 Suppl 1():S53-61. PubMed ID: 11792763
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Three-dimensional simulation of mass transfer in artificial kidneys.
    Ding W; Li W; Sun S; Zhou X; Hardy PA; Ahmad S; Gao D
    Artif Organs; 2015 Jun; 39(6):E79-89. PubMed ID: 25739806
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Extended daily veno-venous high-flux haemodialysis in patients with acute renal failure and multiple organ dysfunction syndrome using a single path batch dialysis system.
    Lonnemann G; Floege J; Kliem V; Brunkhorst R; Koch KM
    Nephrol Dial Transplant; 2000 Aug; 15(8):1189-93. PubMed ID: 10910443
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A comparison of molecular clearance rates during continuous hemofiltration and hemodialysis with a novel volumetric continuous renal replacement system.
    Jeffrey RF; Khan AA; Prabhu P; Todd N; Goutcher E; Will EJ; Davison AM
    Artif Organs; 1994 Jun; 18(6):425-8. PubMed ID: 8060251
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Radionuclide method for evaluating the performance of hemodialysis in vivo.
    Bihl GR; Bird NJ; Peters C; Bradley JR; Peters AM
    Kidney Int; 2005 Feb; 67(2):721-31. PubMed ID: 15673322
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Determinants of ceftriaxone clearance by continuous venovenous hemofiltration and hemodialysis.
    Matzke GR; Frye RF; Joy MS; Palevsky PM
    Pharmacotherapy; 2000 Jun; 20(6):635-43. PubMed ID: 10853618
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Technical evaluation of dialysate flow in a newly designed dialyzer.
    Yamamoto K; Matsukawa H; Yakushiji T; Fukuda M; Hiyoshi T; Sakai K
    ASAIO J; 2007; 53(1):36-40. PubMed ID: 17237647
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Factors affecting urea clearance during continuous hemodiafiltration in the canine model.
    Hiyama DT; Weiss RG; Ryckman FC
    J Pediatr Surg; 1989 Aug; 24(8):756-9. PubMed ID: 2769542
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Single-needle venous dialysis: a comparison of three systems.
    Weinstein AM; Frederick PM; Sullivan JF
    Uremia Invest; 1984-1985; 8(2):69-77. PubMed ID: 6537687
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Hemodialysis blood access flow rates can be estimated accurately from on-line dialysate urea measurements and the knowledge of effective dialyzer urea clearance.
    Lindsay RM; Sternby J; Olde B; Persson R; Thatcher ME; Sargent K
    Clin J Am Soc Nephrol; 2006 Sep; 1(5):960-4. PubMed ID: 17699313
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A model of the volumetrically-controlled hemodialysis circuit.
    Pallone TL; Hyver SW; Petersen J
    Kidney Int; 1992 May; 41(5):1366-73. PubMed ID: 1614051
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effects of a reduced inner diameter of hollow fibers in hemodialyzers.
    Ronco C; Brendolan A; Lupi A; Metry G; Levin NW
    Kidney Int; 2000 Aug; 58(2):809-17. PubMed ID: 10916106
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Slow continuous ultrafiltration with bound solute dialysis.
    Patzer JF; Safta SA; Miller RH
    ASAIO J; 2006; 52(1):47-58. PubMed ID: 16436890
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effects of EPO therapy on backfiltration of dialysate in high flux dialysis.
    Robertson BC; Curtin C
    ASAIO Trans; 1990; 36(3):M447-52. PubMed ID: 2252724
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.