  • 1. An Unusual Complication After Rupture of the SAPIEN 3 Valve Balloon During Transcatheter Aortic Valve Replacement.
    Sawaya FJ; Roy A; Neylon A; Spaziano M; Hovasse T
    JACC Cardiovasc Interv; 2016 Apr; 9(8):e79-e81. PubMed ID: 27101919
    [No Abstract]   [Full Text] [Related]  

  • 2. How should I treat a left ventricular outflow tract-migrated balloon-expandable transcatheter heart valve?
    Barbash IM; Bogdan A; Fefer P; Spiegelstein D; Raanani E; Beinart R; Guetta V; Segev A; Eggebrecht H; Zierer A; Dworakowski R; MacCarthy P
    EuroIntervention; 2016 Mar; 11(12):1442-5. PubMed ID: 26999684
    [No Abstract]   [Full Text] [Related]  

  • 3. Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves.
    Stähli BE; Nguyen-Kim TD; Gebhard C; Erhart L; Frauenfelder T; Tanner FC; Falk V; Landmesser U; Nietlispach F; Lüscher TF; Maier W; Binder RK
    J Heart Valve Dis; 2015 Jan; 24(1):10-21. PubMed ID: 26182615
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Aortic annular rupture during TAVR: Mini review.
    Aksoy O; Paixao AR; Marmagkiolis K; Mego D; Rollefson WA; Cilingiroglu M
    Cardiovasc Revasc Med; 2016; 17(3):199-201. PubMed ID: 27157295
    [No Abstract]   [Full Text] [Related]  

  • 5. Retrograde aortic valve crossing of the CoreValve prosthesis using the buddy balloon technique.
    Noble S; Roffi M
    Catheter Cardiovasc Interv; 2014 Nov; 84(6):897-9. PubMed ID: 24115674
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Initial findings using the V8 hourglass-shaped valvuloplasty balloon for postdilatation in treating paravalvular leaks associated with transcatheter self-expanding aortic valve prosthesis.
    Latib A; Pedersen W; Maisano F; Lesser J; Ruparelia N; Figini F; Colombo A; Poulose A; Kolbeck J; Mooney M; Schwartz R; Youssef A; Ungs D; Goldenberg I; Sorajja P
    Catheter Cardiovasc Interv; 2016 Jun; 87(7):1306-13. PubMed ID: 26945697
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Applicability of next generation balloon-expandable transcatheter heart valves in aortic annuli exceeding formally approved dimensions.
    Schaefer A; Linder M; Treede H; Deuschl F; Schofer N; Seiffert M; Schneeberger Y; Blankenberg S; Reichenspurner H; Schaefer U; Conradi L
    Clin Res Cardiol; 2016 Jul; 105(7):585-91. PubMed ID: 26680213
    [TBL] [Abstract][Full Text] [Related]  

  • 8. How to overcome a scary complication: a mesh-trapped balloon during a CoreValve implantation procedure.
    Bayet G; Collet F; Rochas P; Vicat J; Giacomoni MP; Aymard T
    EuroIntervention; 2016 Mar; 11(12):1434. PubMed ID: 26060086
    [No Abstract]   [Full Text] [Related]  

  • 9. Overexpansion of the SAPIEN 3 Transcatheter Heart Valve: A Feasibility Study.
    Shivaraju A; Kodali S; Thilo C; Ott I; Schunkert H; von Scheidt W; Leon MB; Kastrati A; Kasel AM
    JACC Cardiovasc Interv; 2015 Dec; 8(15):2041-2043. PubMed ID: 26738676
    [No Abstract]   [Full Text] [Related]  

  • 10. Successful post-dilation of a Lotus transcatheter aortic valve in a case of prosthesis frame underexpansion due to leaflet calcification.
    Fuchs F; Tiyerili V; Roell W; Grube E; Werner N; Nickenig G; Sinning JM
    JACC Cardiovasc Interv; 2015 May; 8(6):866-868. PubMed ID: 25912405
    [No Abstract]   [Full Text] [Related]  

  • 11. Fracture of the delivery balloon shaft during balloon-expandable prosthesis alignment during implantation of an Edwards SAPIEN 3.
    Arai T; Hovasse T; Chevalier B
    Catheter Cardiovasc Interv; 2018 Apr; 91(5):997-999. PubMed ID: 27142180
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transfemoral implantation of Edwards Sapien XT aortic valve without previous valvuloplasty: role of 2D/3D transesophageal echocardiography.
    García E; Almería C; Unzué L; Jiménez-Quevedo P; Cuadrado A; Macaya C
    Catheter Cardiovasc Interv; 2014 Nov; 84(6):868-76. PubMed ID: 24482054
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Incidence and severity of paravalvular aortic regurgitation with multidetector computed tomography nominal area oversizing or undersizing after transcatheter heart valve replacement with the Sapien 3: a comparison with the Sapien XT.
    Yang TH; Webb JG; Blanke P; Dvir D; Hansson NC; Nørgaard BL; Thompson CR; Thomas M; Wendler O; Vahanian A; Himbert D; Kodali SK; Hahn RT; Thourani VH; Schymik G; Precious B; Berger A; Wood DA; Pibarot P; Rodés-Cabau J; Jaber WA; Leon MB; Walther T; Leipsic J
    JACC Cardiovasc Interv; 2015 Mar; 8(3):462-471. PubMed ID: 25790764
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Left ventricular outflow tract embolization and balloon assisted recapture of a SAPIEN XT prosthesis during transcatheter aortic valve replacement.
    Seecheran N; Ittleman F; Dauerman H
    Catheter Cardiovasc Interv; 2016 Sep; 88(3):E89-92. PubMed ID: 26602182
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gluing of an Aortic Perforation During Transcatheter Aortic Valve Replacement: An Alternative Treatment for Annular Rupture?
    Piliero N; Thony F; Vanzetto G; Barone-Rochette G
    JACC Cardiovasc Interv; 2015 Dec; 8(15):2037-2038. PubMed ID: 26627993
    [No Abstract]   [Full Text] [Related]  

  • 16. Early Edwards SAPIEN Valve Degeneration After Transcatheter Aortic Valve Replacement.
    Harbaoui B; Courand PY; Schmitt Z; Farhat F; Dauphin R; Lantelme P
    JACC Cardiovasc Interv; 2016 Jan; 9(2):198-9. PubMed ID: 26711004
    [No Abstract]   [Full Text] [Related]  

  • 17. Device success and 30-day clinical outcome in patients undergoing preimplant valvuloplasty in transfemoral versus omitting valvuloplasty in transapical transcatheter aortic valve replacement.
    Wong SC; Pawar S; Minutello RM; Horn EM; Skubas NJ; Devereux RB; Salemi A
    J Thorac Cardiovasc Surg; 2015 Nov; 150(5):1111-7. PubMed ID: 26277463
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Balloon valvuloplasty treatment of an infolded CoreValve.
    Kaple RK; Salemi A; Wong SC
    Catheter Cardiovasc Interv; 2017 Feb; 89(3):499-501. PubMed ID: 26508359
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement.
    Khalique OK; Hahn RT; Gada H; Nazif TM; Vahl TP; George I; Kalesan B; Forster M; Williams MB; Leon MB; Einstein AJ; Pulerwitz TC; Pearson GD; Kodali SK
    JACC Cardiovasc Interv; 2014 Aug; 7(8):885-94. PubMed ID: 25147034
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fluoroscopic calcification-guided optimal deployment projection during transcatheter aortic valve replacement--"The eye of the pigtail." (Follow the right cusp rule--Part II).
    Shivaraju A; Ott I; Cassese S; Bourier F; Kastrati A; Thilo C; von Scheidt W; Kasel AM
    Catheter Cardiovasc Interv; 2016 Apr; 87(5):996-8. PubMed ID: 26173183
    [No Abstract]   [Full Text] [Related]  