These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Retrograde aortic valve crossing of the CoreValve prosthesis using the buddy balloon technique. Noble S; Roffi M Catheter Cardiovasc Interv; 2014 Nov; 84(6):897-9. PubMed ID: 24115674 [TBL] [Abstract][Full Text] [Related]
6. Initial findings using the V8 hourglass-shaped valvuloplasty balloon for postdilatation in treating paravalvular leaks associated with transcatheter self-expanding aortic valve prosthesis. Latib A; Pedersen W; Maisano F; Lesser J; Ruparelia N; Figini F; Colombo A; Poulose A; Kolbeck J; Mooney M; Schwartz R; Youssef A; Ungs D; Goldenberg I; Sorajja P Catheter Cardiovasc Interv; 2016 Jun; 87(7):1306-13. PubMed ID: 26945697 [TBL] [Abstract][Full Text] [Related]
7. Applicability of next generation balloon-expandable transcatheter heart valves in aortic annuli exceeding formally approved dimensions. Schaefer A; Linder M; Treede H; Deuschl F; Schofer N; Seiffert M; Schneeberger Y; Blankenberg S; Reichenspurner H; Schaefer U; Conradi L Clin Res Cardiol; 2016 Jul; 105(7):585-91. PubMed ID: 26680213 [TBL] [Abstract][Full Text] [Related]
8. How to overcome a scary complication: a mesh-trapped balloon during a CoreValve implantation procedure. Bayet G; Collet F; Rochas P; Vicat J; Giacomoni MP; Aymard T EuroIntervention; 2016 Mar; 11(12):1434. PubMed ID: 26060086 [No Abstract] [Full Text] [Related]
9. Overexpansion of the SAPIEN 3 Transcatheter Heart Valve: A Feasibility Study. Shivaraju A; Kodali S; Thilo C; Ott I; Schunkert H; von Scheidt W; Leon MB; Kastrati A; Kasel AM JACC Cardiovasc Interv; 2015 Dec; 8(15):2041-2043. PubMed ID: 26738676 [No Abstract] [Full Text] [Related]
10. Successful post-dilation of a Lotus transcatheter aortic valve in a case of prosthesis frame underexpansion due to leaflet calcification. Fuchs F; Tiyerili V; Roell W; Grube E; Werner N; Nickenig G; Sinning JM JACC Cardiovasc Interv; 2015 May; 8(6):866-868. PubMed ID: 25912405 [No Abstract] [Full Text] [Related]
11. Fracture of the delivery balloon shaft during balloon-expandable prosthesis alignment during implantation of an Edwards SAPIEN 3. Arai T; Hovasse T; Chevalier B Catheter Cardiovasc Interv; 2018 Apr; 91(5):997-999. PubMed ID: 27142180 [TBL] [Abstract][Full Text] [Related]
12. Transfemoral implantation of Edwards Sapien XT aortic valve without previous valvuloplasty: role of 2D/3D transesophageal echocardiography. García E; Almería C; Unzué L; Jiménez-Quevedo P; Cuadrado A; Macaya C Catheter Cardiovasc Interv; 2014 Nov; 84(6):868-76. PubMed ID: 24482054 [TBL] [Abstract][Full Text] [Related]
13. Incidence and severity of paravalvular aortic regurgitation with multidetector computed tomography nominal area oversizing or undersizing after transcatheter heart valve replacement with the Sapien 3: a comparison with the Sapien XT. Yang TH; Webb JG; Blanke P; Dvir D; Hansson NC; Nørgaard BL; Thompson CR; Thomas M; Wendler O; Vahanian A; Himbert D; Kodali SK; Hahn RT; Thourani VH; Schymik G; Precious B; Berger A; Wood DA; Pibarot P; Rodés-Cabau J; Jaber WA; Leon MB; Walther T; Leipsic J JACC Cardiovasc Interv; 2015 Mar; 8(3):462-471. PubMed ID: 25790764 [TBL] [Abstract][Full Text] [Related]
14. Left ventricular outflow tract embolization and balloon assisted recapture of a SAPIEN XT prosthesis during transcatheter aortic valve replacement. Seecheran N; Ittleman F; Dauerman H Catheter Cardiovasc Interv; 2016 Sep; 88(3):E89-92. PubMed ID: 26602182 [TBL] [Abstract][Full Text] [Related]
15. Gluing of an Aortic Perforation During Transcatheter Aortic Valve Replacement: An Alternative Treatment for Annular Rupture? Piliero N; Thony F; Vanzetto G; Barone-Rochette G JACC Cardiovasc Interv; 2015 Dec; 8(15):2037-2038. PubMed ID: 26627993 [No Abstract] [Full Text] [Related]
17. Device success and 30-day clinical outcome in patients undergoing preimplant valvuloplasty in transfemoral versus omitting valvuloplasty in transapical transcatheter aortic valve replacement. Wong SC; Pawar S; Minutello RM; Horn EM; Skubas NJ; Devereux RB; Salemi A J Thorac Cardiovasc Surg; 2015 Nov; 150(5):1111-7. PubMed ID: 26277463 [TBL] [Abstract][Full Text] [Related]
18. Balloon valvuloplasty treatment of an infolded CoreValve. Kaple RK; Salemi A; Wong SC Catheter Cardiovasc Interv; 2017 Feb; 89(3):499-501. PubMed ID: 26508359 [TBL] [Abstract][Full Text] [Related]
19. Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement. Khalique OK; Hahn RT; Gada H; Nazif TM; Vahl TP; George I; Kalesan B; Forster M; Williams MB; Leon MB; Einstein AJ; Pulerwitz TC; Pearson GD; Kodali SK JACC Cardiovasc Interv; 2014 Aug; 7(8):885-94. PubMed ID: 25147034 [TBL] [Abstract][Full Text] [Related]
20. Fluoroscopic calcification-guided optimal deployment projection during transcatheter aortic valve replacement--"The eye of the pigtail." (Follow the right cusp rule--Part II). Shivaraju A; Ott I; Cassese S; Bourier F; Kastrati A; Thilo C; von Scheidt W; Kasel AM Catheter Cardiovasc Interv; 2016 Apr; 87(5):996-8. PubMed ID: 26173183 [No Abstract] [Full Text] [Related] [Next] [New Search]