240 related articles for article (PubMed ID: 27106743)
1. Twisting wire technique: An effective method to retrieve fractured guide wire fragments from coronary arteries.
Devidutta S; Lim ST
Cardiovasc Revasc Med; 2016 Jun; 17(4):282-6. PubMed ID: 27106743
[TBL] [Abstract][Full Text] [Related]
2. Percutaneous retrieval of a twisted guide catheter using a longer second radial sheath.
Leibundgut G; Löffelhardt N; Neumann FJ
Catheter Cardiovasc Interv; 2014 Mar; 83(4):560-3. PubMed ID: 24285592
[TBL] [Abstract][Full Text] [Related]
3. Retrieval of fractured guide wire with balloon support in intermediate coronary artery: A rare complication and management.
Yildiz BS; Kilic ID; Alihanoglu YI; Evrengul H
Indian Heart J; 2016; 68(3):361-3. PubMed ID: 27316491
[No Abstract] [Full Text] [Related]
4. Retrieval of trapped and broken guide wire with immediate rescue off-pump coronary bypass surgery.
Singh D; Darbari A
Interact Cardiovasc Thorac Surg; 2014 Sep; 19(3):529-31. PubMed ID: 24871531
[TBL] [Abstract][Full Text] [Related]
5. One, two, three … breakdance and twist.
Aranzulla TC
Catheter Cardiovasc Interv; 2020 Sep; 96(3):601-608. PubMed ID: 31797536
[TBL] [Abstract][Full Text] [Related]
6. Percutaneous wire rescue during radial sheath insertion.
Santos PM; Del Castillo Medina R; Marrupe LH; Rodríguez JB
Cardiovasc Revasc Med; 2014 Mar; 15(2):125-6. PubMed ID: 24095037
[TBL] [Abstract][Full Text] [Related]
7. Fractured Wire in the Left Internal Mammary Artery: A Novel Retrieval Technique.
Dyal MD; Damluji AA; Rengifo-Moreno P; de Marchena EJ
J Invasive Cardiol; 2017 Mar; 29(3):E39-E40. PubMed ID: 28255108
[TBL] [Abstract][Full Text] [Related]
8. Retrograde guidewire fracture complicated with pericardial tamponade in chronic total occlusive coronary lesion.
Park SH; Rha SW; Her K
Int J Cardiovasc Imaging; 2015 Oct; 31(7):1293-4. PubMed ID: 26150001
[TBL] [Abstract][Full Text] [Related]
9. Consequences and treatment of guidewire entrapment and fracture during percutaneous coronary intervention.
Danek BA; Karatasakis A; Brilakis ES
Cardiovasc Revasc Med; 2016 Mar; 17(2):129-33. PubMed ID: 26826011
[TBL] [Abstract][Full Text] [Related]
10. Retrieval of a fractured angioplasty guidewire after percutaneous retrograde revascularization of coronary chronic total occlusion.
Baumann S; Rupp D; Becher T; Behnes M; Sadick M; Borggrefe M; Akin I
Coron Artery Dis; 2018 Jan; 29(1):81-82. PubMed ID: 28799980
[No Abstract] [Full Text] [Related]
11. Experience and complications associated with use of guide extension catheters in percutaneous coronary intervention.
Waterbury TM; Sorajja P; Bell MR; Lennon RJ; Mathew V; Singh M; Sandhu GS; Gulati R
Catheter Cardiovasc Interv; 2016 Dec; 88(7):1057-1065. PubMed ID: 26698371
[TBL] [Abstract][Full Text] [Related]
12. Fractured Guidewire Entrapped in the Ostium of Right Coronary Artery Mimicking Aortic Flap.
Meledin V; Perkhulov V; Gandelman G; George J; Shimoni S
JACC Cardiovasc Interv; 2019 May; 12(9):890-891. PubMed ID: 30981570
[No Abstract] [Full Text] [Related]
13. Retrieval of a subintimal fractured guide wire from the brachial artery following saphenous vein graft stenting.
Danson EJ; Ward M
Catheter Cardiovasc Interv; 2015 Jun; 85(7):E171-4. PubMed ID: 25345676
[TBL] [Abstract][Full Text] [Related]
14. Transfemoral use of the GuideLiner catheter in complex coronary and bypass graft interventions.
Luna M; Papayannis A; Holper EM; Banerjee S; Brilakis ES
Catheter Cardiovasc Interv; 2012 Sep; 80(3):437-46. PubMed ID: 21805572
[TBL] [Abstract][Full Text] [Related]
15. Safety of hydrophilic guidewires used for side-branch protection during stenting and proximal optimization technique in coronary bifurcation lesions.
Chatterjee A; Brott BC; Foley R; Alli O; Sasse M; Ahmed M; Al Solaiman F; Reddy G; Ather S; Leesar MA
Cardiovasc Revasc Med; 2016; 17(7):456-462. PubMed ID: 27210866
[TBL] [Abstract][Full Text] [Related]
16. Retained Coronary Balloon Requiring Emergent Open Surgical Retrieval: An Uncommon Complication Requiring Individualized Management Strategies.
Desai CK; Petrasko M; Steffen K; Stys T; Stys A
Methodist Debakey Cardiovasc J; 2019; 15(1):81-85. PubMed ID: 31049154
[TBL] [Abstract][Full Text] [Related]
17. A unique complication with use of the GuideLiner catheter in percutaneous coronary interventions and its successful management.
Bhat T; Baydoun H; Tamburino F
J Invasive Cardiol; 2014 Apr; 26(4):E42-4. PubMed ID: 24717280
[TBL] [Abstract][Full Text] [Related]
18. Unintentional extraction of an endothelized coronary stent with an aspiration catheter during primary percutaneous coronary intervention.
Baz JA; Jiménez VA; Sepúlveda J; Chantada D; Díaz CM; Juan-Salvadores P; Iñiguez A
Circ Cardiovasc Interv; 2015 Feb; 8(2):e002114. PubMed ID: 25634904
[No Abstract] [Full Text] [Related]
19. Triple wire technique for removal of fractured angioplasty guidewire.
Collins N; Horlick E; Dzavik V
J Invasive Cardiol; 2007 Aug; 19(8):E230-4. PubMed ID: 17712212
[TBL] [Abstract][Full Text] [Related]
20. Severe catheter kinking and entrapment during transradial coronary angiography: percutaneous retrieval using a sheathless guide catheter.
Aminian A; Fraser DG; Dolatabadi D
Catheter Cardiovasc Interv; 2015 Jan; 85(1):91-4. PubMed ID: 24740882
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]