166 related articles for article (PubMed ID: 27114250)
1. Assessment of the Reliability of the Sysmex XE-5000 Analyzer to Detect Platelet Clumps.
Hawkins J; Gulati G; Uppal G; Gong J
Lab Med; 2016 Aug; 47(3):189-94. PubMed ID: 27114250
[TBL] [Abstract][Full Text] [Related]
2. [Diagnostic performance of graphical anomalies in the detection of large platelets and platelet clumps].
Sassi M; Dibej W; Abdi B; Abderrazak F; Hassine M; Babba H
Pathol Biol (Paris); 2015 Dec; 63(6):248-51. PubMed ID: 26524955
[TBL] [Abstract][Full Text] [Related]
3. Two cases of false platelet clumps flagged by the automated hematology analyzer Sysmex XE-2100.
Dai Q; Zhang G; Lai C; Du Z; Chen L; Chen Q; Peng L; Wang Y; Yang H; Ye L; Yang X; Jiang Y
Clin Chim Acta; 2014 Feb; 429():152-6. PubMed ID: 24362232
[TBL] [Abstract][Full Text] [Related]
4. Comparison of platelet counts by sysmex XE 2100 and LH-750 with the international flow reference method in thrombocytopenic patients.
Dadu T; Sehgal K; Shaikh A; Khodaiji S
Indian J Pathol Microbiol; 2013; 56(2):114-9. PubMed ID: 24056646
[TBL] [Abstract][Full Text] [Related]
5. The flagging features of the Sysmex XN-10 analyser for detecting platelet clumps and the impacts of platelet clumps on complete blood count parameters.
Xu P; Fang K; Chen X; Liu Y; Dong Z; Zhu J; Lu K
Clin Chem Lab Med; 2022 Apr; 60(5):748-755. PubMed ID: 35212492
[TBL] [Abstract][Full Text] [Related]
6. [XE-2100: platelet clumps or polymorphonuclear neutrophil aggregates, that is the question].
Dubois-Galopin F; Lamballais F; Rapatel C; Berger MG
Ann Biol Clin (Paris); 2010; 68(4):480-4. PubMed ID: 20650744
[TBL] [Abstract][Full Text] [Related]
7. [Evaluation of Immature Platelet Fraction Measurements Using an Automated Hematology Analyzer, Sysmex XN].
Yoshikawa N; Masuda A; Jona M; Okubo S; Nannya Y; Yokota H; Kurokawa M; Yatomi Y
Rinsho Byori; 2016 Nov; 64(11):1220-1228. PubMed ID: 30695302
[TBL] [Abstract][Full Text] [Related]
8. [Reliability of low platelet counts--comparison of microscopic counts with automated hematology analyzer XE-2100].
Orito M; Shibayama M; Yoshida T; Takami A; Asakura H; Fujita S; Nakao S
Rinsho Byori; 2005 Sep; 53(9):793-801. PubMed ID: 16235831
[TBL] [Abstract][Full Text] [Related]
9. Performance Evaluation of the Mindray BC 6800 Hematology Analyzer and Flag Comparison with the XE-2100 and Manual Microscopy.
Xiang D; Yue J; Sha C; Ren S; Li M; Wang C
Clin Lab; 2019 Apr; 65(4):. PubMed ID: 30969092
[TBL] [Abstract][Full Text] [Related]
10. Performance evaluation of the white cell precursor channel on the Sysmex XN hematology analyzer in HIV specimens.
Schapkaitz E; Khoza P
J Clin Lab Anal; 2018 May; 32(4):e22335. PubMed ID: 28948641
[TBL] [Abstract][Full Text] [Related]
11. The value of the white precursor cell channel (WPC) on the Sysmex XN-1000 analyser in a specialist paediatric hospital.
Jones AS; Tailor H; Liesner R; Machin SJ; Briggs CJ
J Clin Pathol; 2015 Feb; 68(2):161-5. PubMed ID: 25425659
[TBL] [Abstract][Full Text] [Related]
12. Performance evaluation of the Sysmex XN-1000 hematology analyzer in assessment of the white blood cell count differential in pediatric specimens.
Becker PH; Fenneteau O; Da Costa L
Int J Lab Hematol; 2016 Feb; 38(1):54-63. PubMed ID: 26407903
[TBL] [Abstract][Full Text] [Related]
13. Mean platelet volume: comparison of three analysers towards standardization of platelet morphological phenotype.
Latger-Cannard V; Hoarau M; Salignac S; Baumgart D; Nurden P; Lecompte T
Int J Lab Hematol; 2012 Jun; 34(3):300-10. PubMed ID: 22225539
[TBL] [Abstract][Full Text] [Related]
14. The diagnostic accuracy of Sysmex XN for identification of pseudothrombocytopenia using various thresholds for definition of platelet aggregation.
Lunde HE; Hjelmtvedt AN; Amundsen EK
Int J Lab Hematol; 2022 Oct; 44(5):854-860. PubMed ID: 35751410
[TBL] [Abstract][Full Text] [Related]
15. Performance evaluation of Sysmex XN hematology analyzer in umbilical cord blood: a comparison study with Sysmex XE-2100.
Kim H; Hur M; Choi SG; Moon HW; Yun YM; Hwang HS; Kwon HS; Sohn IS
Clin Chem Lab Med; 2014 Dec; 52(12):1771-9. PubMed ID: 24978899
[TBL] [Abstract][Full Text] [Related]
16. Comparison of abnormal cell flagging of the hematology analyzers Sysmex XN and Sysmex XE-5000 in oncohematologic patients.
Furundarena JR; Sainz M; Uranga A; Cuevas L; Lopez I; Zubicaray J; Bizjak A; Robado N; Araiz M
Int J Lab Hematol; 2017 Feb; 39(1):58-67. PubMed ID: 27981789
[TBL] [Abstract][Full Text] [Related]
17. New Alert Message Settings for the XN-series Automated Hematology Analyzer Are Useful for Avoiding Falsely High WBC Counts and to Detect Specimens with Giant Platelets.
Inaba T; Shimomoto B; Yuki Y; Okumura K; Nishimura H; Koshino K; Nobori S; Wada A; Fujita N
Ann Clin Lab Sci; 2017 Sep; 47(5):581-585. PubMed ID: 29066485
[TBL] [Abstract][Full Text] [Related]
18. Erroneous automated optical platelet counts in 1-hour post-transfusion blood samples.
Maurer-Spurej E; Pittendreigh C; Yakimec J; De Badyn MH; Chipperfield K
Int J Lab Hematol; 2010 Feb; 32(1 Pt 1):e1-8. PubMed ID: 18752538
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of Mindray BC-5000 hematology analyzer: a new miniature 5-part WBC differential instrument.
Xiang D; Yue J; Lan Y; Sha C; Ren S; Li Y; Li M; Wang C
Int J Lab Hematol; 2015 Oct; 37(5):597-605. PubMed ID: 25944368
[TBL] [Abstract][Full Text] [Related]
20. Automated five-part white blood cell differential counts. Efficiency of software-generated white blood cell suspect flags of the hematology analyzers Sysmex SE-9000, Sysmex NE-8000, and Coulter STKS.
Thalhammer-Scherrer R; Knöbl P; Korninger L; Schwarzinger I
Arch Pathol Lab Med; 1997 Jun; 121(6):573-7. PubMed ID: 9199621
[TBL] [Abstract][Full Text] [Related]