These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
144 related articles for article (PubMed ID: 27116517)
1. Relation Between Implant Position and Perceptual Threshold in a Patient with Epiretinal Prosthesis System. Tran BK; Wolfensberger TJ Klin Monbl Augenheilkd; 2016 Apr; 233(4):493-5. PubMed ID: 27116517 [No Abstract] [Full Text] [Related]
2. [Clinical Results after Implantation of Epiretinal Visual Prostheses]. Schimitzek H; Roessler G; Walter P Klin Monbl Augenheilkd; 2016 Nov; 233(11):1227-1232. PubMed ID: 27676329 [TBL] [Abstract][Full Text] [Related]
3. The first deaf-blind patient in Russia with Argus II retinal prosthesis system: what he sees and why. Demchinsky AM; Shaimov TB; Goranskaya DN; Moiseeva IV; Kuznetsov DI; Kuleshov DS; Polikanov DV J Neural Eng; 2019 Apr; 16(2):025002. PubMed ID: 30620937 [TBL] [Abstract][Full Text] [Related]
4. The Argus™ II retinal prosthesis: factors affecting patient selection for implantation. Ahuja AK; Behrend MR Prog Retin Eye Res; 2013 Sep; 36():1-23. PubMed ID: 23500412 [TBL] [Abstract][Full Text] [Related]
5. The artificial silicon retina microchip for the treatment of vision loss from retinitis pigmentosa. Chow AY; Chow VY; Packo KH; Pollack JS; Peyman GA; Schuchard R Arch Ophthalmol; 2004 Apr; 122(4):460-9. PubMed ID: 15078662 [TBL] [Abstract][Full Text] [Related]
6. Positive Visual Phenomena Following Implantation of the Argus II Retinal Prosthesis. Sadaka A; Iqbal C; Nazari H; Berry S; Wykoff CC; Humayun MS; Lee AG Ophthalmic Surg Lasers Imaging Retina; 2017 Dec; 48(12):1022-1025. PubMed ID: 29253307 [TBL] [Abstract][Full Text] [Related]
7. Ten-Year Follow-up of a Blind Patient Chronically Implanted with Epiretinal Prosthesis Argus I. Yue L; Falabella P; Christopher P; Wuyyuru V; Dorn J; Schor P; Greenberg RJ; Weiland JD; Humayun MS Ophthalmology; 2015 Dec; 122(12):2545-52.e1. PubMed ID: 26386850 [TBL] [Abstract][Full Text] [Related]
8. A test method for quantification of stimulus-induced depression effects on perceptual threshold in epiretinal prosthesis. Velikay-Parel M; Ivastinovic D; Georgi T; Richard G; Hornig R Acta Ophthalmol; 2013 Dec; 91(8):e595-602. PubMed ID: 24112756 [TBL] [Abstract][Full Text] [Related]
9. Feasibility study of a retinal prosthesis: spatial vision with a 16-electrode implant. Caspi A; Dorn JD; McClure KH; Humayun MS; Greenberg RJ; McMahon MJ Arch Ophthalmol; 2009 Apr; 127(4):398-401. PubMed ID: 19365014 [TBL] [Abstract][Full Text] [Related]
10. Long-Term Results from an Epiretinal Prosthesis to Restore Sight to the Blind. Ho AC; Humayun MS; Dorn JD; da Cruz L; Dagnelie G; Handa J; Barale PO; Sahel JA; Stanga PE; Hafezi F; Safran AB; Salzmann J; Santos A; Birch D; Spencer R; Cideciyan AV; de Juan E; Duncan JL; Eliott D; Fawzi A; Olmos de Koo LC; Brown GC; Haller JA; Regillo CD; Del Priore LV; Arditi A; Geruschat DR; Greenberg RJ; Ophthalmology; 2015 Aug; 122(8):1547-54. PubMed ID: 26162233 [TBL] [Abstract][Full Text] [Related]
11. Implantation and explantation of a wireless epiretinal retina implant device: observations during the EPIRET3 prospective clinical trial. Roessler G; Laube T; Brockmann C; Kirschkamp T; Mazinani B; Goertz M; Koch C; Krisch I; Sellhaus B; Trieu HK; Weis J; Bornfeld N; Röthgen H; Messner A; Mokwa W; Walter P Invest Ophthalmol Vis Sci; 2009 Jun; 50(6):3003-8. PubMed ID: 19420330 [TBL] [Abstract][Full Text] [Related]
12. [Retinal and Cortical Activation by Electrical Stimulation with Retina Implants]. Stett A; Eysel UT Klin Monbl Augenheilkd; 2016 Nov; 233(11):1213-1221. PubMed ID: 27855445 [TBL] [Abstract][Full Text] [Related]
13. Perceptual thresholds and electrode impedance in three retinal prosthesis subjects. Mahadevappa M; Weiland JD; Yanai D; Fine I; Greenberg RJ; Humayun MS IEEE Trans Neural Syst Rehabil Eng; 2005 Jun; 13(2):201-6. PubMed ID: 16003900 [TBL] [Abstract][Full Text] [Related]
14. Case Report: Effect of a Retinal Prosthesis System on Charles Bonnet Visual Hallucinations. Moore V; Cantin S; Carignan M; Courchesne M; Qian CX; Poncet F Optom Vis Sci; 2020 Dec; 97(12):1023-1028. PubMed ID: 33259381 [TBL] [Abstract][Full Text] [Related]
18. Effect of sham surgery on retinal function after subretinal transplantation of the artificial silicone retina. Del Priore LV Arch Ophthalmol; 2005 Aug; 123(8):1156; author reply 1156-7. PubMed ID: 16087860 [No Abstract] [Full Text] [Related]
19. Frequency and amplitude modulation have different effects on the percepts elicited by retinal stimulation. Nanduri D; Fine I; Horsager A; Boynton GM; Humayun MS; Greenberg RJ; Weiland JD Invest Ophthalmol Vis Sci; 2012 Jan; 53(1):205-14. PubMed ID: 22110084 [TBL] [Abstract][Full Text] [Related]
20. Changes in microchip position after implantation of a subretinal vision prosthesis in humans. Kuehlewein L; Troelenberg N; Stingl K; Schleehauf S; Kusnyerik A; Jackson TL; MacLaren RE; Chee C; Roider J; Wilhelm B; Gekeler F; Bartz-Schmidt KU; Zrenner E; Stingl K Acta Ophthalmol; 2019 Sep; 97(6):e871-e876. PubMed ID: 30816625 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]