280 related articles for article (PubMed ID: 27127208)
1. CALCULATION OF GAMMA SPECTRA IN A PLASTIC SCINTILLATOR FOR ENERGY CALIBRATIONAND DOSE COMPUTATION.
Kim C; Yoo H; Kim Y; Moon M; Kim JY; Kang DU; Lee D; Kim MS; Cho M; Lee E; Cho G
Radiat Prot Dosimetry; 2016 Sep; 170(1-4):377-81. PubMed ID: 27127208
[TBL] [Abstract][Full Text] [Related]
2. Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy.
Ebenau M; Radeck D; Bambynek M; Sommer H; Flühs D; Spaan B; Eichmann M
Med Phys; 2016 Aug; 43(8):4598. PubMed ID: 27487876
[TBL] [Abstract][Full Text] [Related]
3. A comparison between Monte Carlo-calculated and -measured total efficiencies and energy resolution for large plastic scintillators used in whole-body counting.
Nilsson J; Isaksson M
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):555-9. PubMed ID: 21044997
[TBL] [Abstract][Full Text] [Related]
4. PLASTIC SCINTILLATOR FOR RADIATION DOSIMETRY.
Kim Y; Yoo H; Kim C; Lim KT; Moon M; Kim J; Cho G
Radiat Prot Dosimetry; 2016 Sep; 170(1-4):187-90. PubMed ID: 26538616
[TBL] [Abstract][Full Text] [Related]
5. Characterizing the response of miniature scintillation detectors when irradiated with proton beams.
Archambault L; Polf JC; Beaulieu L; Beddar S
Phys Med Biol; 2008 Apr; 53(7):1865-76. PubMed ID: 18364543
[TBL] [Abstract][Full Text] [Related]
6. A systematic characterization of the low-energy photon response of plastic scintillation detectors.
Boivin J; Beddar S; Bonde C; Schmidt D; Culberson W; Guillemette M; Beaulieu L
Phys Med Biol; 2016 Aug; 61(15):5569-86. PubMed ID: 27384872
[TBL] [Abstract][Full Text] [Related]
7. Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators.
Beddar AS; Briere TM; Mourtada FA; Vassiliev ON; Liu HH; Mohan R
Med Phys; 2005 May; 32(5):1265-9. PubMed ID: 15984678
[TBL] [Abstract][Full Text] [Related]
8. Experimental investigation on the accuracy of plastic scintillators and of the spectrum discrimination method in small photon fields.
Papaconstadopoulos P; Archambault L; Seuntjens J
Med Phys; 2017 Feb; 44(2):654-664. PubMed ID: 27997030
[TBL] [Abstract][Full Text] [Related]
9. EPR study of radiation stability of organic plastic scintillator for cardiovascular brachytherapy Sr90-Y90 beta dosimetry.
Alcón EP; Lopes RT; de Almeida CE
Appl Radiat Isot; 2005 Feb; 62(2):301-6. PubMed ID: 15607465
[TBL] [Abstract][Full Text] [Related]
10. Light output measurements and computational models of microcolumnar CsI scintillators for x-ray imaging.
Nillius P; Klamra W; Sibczynski P; Sharma D; Danielsson M; Badano A
Med Phys; 2015 Feb; 42(2):600-605. PubMed ID: 28102604
[TBL] [Abstract][Full Text] [Related]
11. Exposure rate by the spectrum dose index method using plastic scintillator detectors.
Proctor A; Wellman J
Radiat Prot Dosimetry; 2012 Apr; 149(3):309-14. PubMed ID: 21712256
[TBL] [Abstract][Full Text] [Related]
12. Percentage depth dose calculation accuracy of model based algorithms in high energy photon small fields through heterogeneous media and comparison with plastic scintillator dosimetry.
Alagar AG; Mani GK; Karunakaran K
J Appl Clin Med Phys; 2016 Jan; 17(1):132-142. PubMed ID: 26894345
[TBL] [Abstract][Full Text] [Related]
13. Energy dependence of a scintillating fiber detector for preclinical dosimetry with an image guided micro-irradiator.
Le Deroff C; Frelin AM; Ledoux X
Phys Med Biol; 2019 May; 64(11):115015. PubMed ID: 30974415
[TBL] [Abstract][Full Text] [Related]
14. AN EVALUATION OF THE BASIC CHARACTERISTICS OF A PLASTIC SCINTILLATING FIBRE DETECTOR IN CT RADIATION FIELDS.
Terasaki K; Fujibuchi T; Toyoda T; Yoshida Y; Akasaka T; Nohtomi A; Morishita J
Radiat Prot Dosimetry; 2016 Dec; 171(4):527-533. PubMed ID: 26586002
[TBL] [Abstract][Full Text] [Related]
15. Streak camera measurement of subnanosecond plastic scintillator properties.
Cheng JC; Tirsell KG; Tripp GR; Lent EM; Lerche RA
Rev Sci Instrum; 1978 May; 49(5):650. PubMed ID: 18699166
[TBL] [Abstract][Full Text] [Related]
16. Fabrication and characterization of a stemless plastic scintillation detector.
Hupman MA; Monajemi T; Valitova I; Hill IG; Syme A
Med Phys; 2020 Nov; 47(11):5882-5889. PubMed ID: 32966652
[TBL] [Abstract][Full Text] [Related]
17. Plastic scintillation dosimetry: optimal selection of scintillating fibers and scintillators.
Archambault L; Arsenault J; Gingras L; Beddar AS; Roy R; Beaulieu L
Med Phys; 2005 Jul; 32(7):2271-8. PubMed ID: 16121582
[TBL] [Abstract][Full Text] [Related]
18. Determination of the energy dependence of the BC-408 plastic scintillation detector in medium energy x-ray beams.
Yücel H; Çubukçu Ş; Uyar E; Engin Y
Phys Med Biol; 2014 Nov; 59(22):6749-58. PubMed ID: 25327627
[TBL] [Abstract][Full Text] [Related]
19. Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography.
Hoerner MR; Stepusin EJ; Hyer DE; Hintenlang DE
Med Phys; 2015 Mar; 42(3):1268-79. PubMed ID: 25735282
[TBL] [Abstract][Full Text] [Related]
20. Response of plastic scintillators to low-energy photons.
Peralta L; Rêgo F
Phys Med Biol; 2014 Aug; 59(16):4621-33. PubMed ID: 25079252
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]