67 related articles for article (PubMed ID: 27129137)
1. Histologic diagnosis of pancreatic masses using 25-gauge endoscopic ultrasound needles with and without a core trap: a multicenter randomized trial.
Kamata K; Kitano M; Yasukawa S; Kudo M; Chiba Y; Ogura T; Higuchi K; Fukutake N; Ashida R; Yamasaki T; Nebiki H; Hirose S; Hoki N; Asada M; Yazumi S; Takaoka M; Okazaki K; Matsuda F; Okabe Y; Yanagisawa A
Endoscopy; 2016 Jul; 48(7):632-8. PubMed ID: 27129137
[TBL] [Abstract][Full Text] [Related]
2. Systematic Review and Meta-Analysis of Diagnostic Accuracy of Endoscopic Ultrasound (EUS)-Guided Fine-Needle Aspiration (FNA) Using 22-gauge and 25-gauge Needles for Pancreatic Masses.
Tian G; Bao H; Li J; Jiang T
Med Sci Monit; 2018 Nov; 24():8333-8341. PubMed ID: 30452433
[TBL] [Abstract][Full Text] [Related]
3. Effectiveness of Menghini-Type Needles for Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Masses.
Mizukawa S; Kato H; Matsumoto K; Muro S; Akimoto Y; Uchida D; Tomoda T; Yamamoto N; Horiguchi S; Tsutsumi K; Inoue H; Tanaka N; Okada H
Dig Dis Sci; 2021 Sep; 66(9):3171-3178. PubMed ID: 33078322
[TBL] [Abstract][Full Text] [Related]
4. 22G Acquire vs. 20G Procore needle for endoscopic ultrasound-guided biopsy of pancreatic masses: a randomized study comparing histologic sample quantity and diagnostic accuracy.
Karsenti D; Palazzo L; Perrot B; Zago J; Lemaistre AI; Cros J; Napoléon B
Endoscopy; 2020 Sep; 52(9):747-753. PubMed ID: 32408361
[TBL] [Abstract][Full Text] [Related]
5. Comparison of 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma using endoscopic ultrasound fine-needle aspiration.
Okuno M; Iwata K; Mukai T; Kito Y; Tanaka T; Watanabe N; Kasahara S; Iwasa Y; Sugiyama A; Nishigaki Y; Shibata Y; Kitagawa J; Iwashita T; Tomita E; Shimizu M
Clin Endosc; 2024 May; 57(3):364-374. PubMed ID: 37743067
[TBL] [Abstract][Full Text] [Related]
6. Optimization of endoscopic ultrasound-guided tissue sample acquisition for commercially available comprehensive genome profiling.
Ishikawa K; Ishiwatari H; Sasaki K; Niiya F; Satoh T; Sato J; Matsubayashi H; Minamide T; Yamamoto Y; Yoshida M; Maeda Y; Kawata N; Takada K; Kishida Y; Imai K; Hotta K; Notsu A; Ono H
J Gastroenterol Hepatol; 2023 Oct; 38(10):1794-1801. PubMed ID: 37495215
[TBL] [Abstract][Full Text] [Related]
7. Comparison of a Novel Thin-Walled 25-gauge Needle Push Button Blood Collection Set to a Standard 23-gauge Needle in a Cancer Patient Population.
Kirchhoff D; Baser R; Kwong D; Ramanathan L; McCash SI
J Appl Lab Med; 2023 Mar; 8(2):264-271. PubMed ID: 36680315
[TBL] [Abstract][Full Text] [Related]
8. Bending 30-gauge needles using a needle guide: fatigue life evaluation.
Tuttle JJ; Davidson AD; Tuttle GK
J Dent Anesth Pain Med; 2023 Oct; 23(5):281-285. PubMed ID: 37841519
[TBL] [Abstract][Full Text] [Related]
9. Shorter observation times and smaller gauge needles in outpatient kidney biopsies.
Giniyani LL; McGee J; DeVita MV; Rahman RT; Moses AA; Rosenstock JL
Clin Nephrol; 2024 May; ():. PubMed ID: 38699984
[TBL] [Abstract][Full Text] [Related]
10. Macroscopic on-site magnifier-based evaluation to estimate visible tissue core cut-off lengths using EUS-FNA with 22-gauge needles.
Huang J; Cheng G; Wu W; Xu L; Xu L; Hu D
Chin Med J (Engl); 2024 Feb; 137(4):493-495. PubMed ID: 38243714
[No Abstract] [Full Text] [Related]
11. Routine pre-procedural rectal indometacin versus selective post-procedural rectal indometacin to prevent pancreatitis in patients undergoing endoscopic retrograde cholangiopancreatography: a multicentre, single-blinded, randomised controlled trial.
Luo H; Zhao L; Leung J; Zhang R; Liu Z; Wang X; Wang B; Nie Z; Lei T; Li X; Zhou W; Zhang L; Wang Q; Li M; Zhou Y; Liu Q; Sun H; Wang Z; Liang S; Guo X; Tao Q; Wu K; Pan Y; Guo X; Fan D
Lancet; 2016 Jun; 387(10035):2293-2301. PubMed ID: 27133971
[TBL] [Abstract][Full Text] [Related]
12. Influence of biliary stents on the diagnostic outcome of endoscopic ultrasound-guided tissue acquisition from solid pancreatic lesions: a systematic review and meta-analysis.
Giri S; Afzalpurkar S; Angadi S; Varghese J; Sundaram S
Clin Endosc; 2023 Mar; 56(2):169-179. PubMed ID: 37013391
[TBL] [Abstract][Full Text] [Related]
13. Comparative diagnostic accuracy of EUS needles in solid pancreatic masses: a network meta-analysis.
Han S; Bhullar F; Alaber O; Kamal A; Hopson P; Kanthasamy K; Coughlin S; Archibugi L; Thiruvengadam N; Moreau C; Jin D; Paragomi P; Valverde-López F; Nagpal S; Yazici C; Papchristou G; Lee PJ; Akshintala V;
Endosc Int Open; 2021 Jun; 9(6):E853-E862. PubMed ID: 34079867
[No Abstract] [Full Text] [Related]
14. Clinical and Technical Guideline for Endoscopic Ultrasound (EUS)-Guided Tissue Acquisition of Pancreatic Solid Tumor: Korean Society of Gastrointestinal Endoscopy (KSGE).
Chung MJ; Park SW; Kim SH; Cho CM; Choi JH; Choi EK; Lee TH; Cho E; Lee JK; Song TJ; Lee JM; Son JH; Park JS; Oh CH; Park DA; Byeon JS; Lee ST; Kim HG; Chun HJ; Choi HS; Park CG; Cho JY
Gut Liver; 2021 May; 15(3):354-374. PubMed ID: 33767027
[TBL] [Abstract][Full Text] [Related]
15. Clinical and Technical Guideline for Endoscopic Ultrasound (EUS)-Guided Tissue Acquisition of Pancreatic Solid Tumor: Korean Society of Gastrointestinal Endoscopy (KSGE).
Chung MJ; Park SW; Kim SH; Cho CM; Choi JH; Choi EK; Lee TH; Cho E; Lee JK; Song TJ; Lee JM; Son JH; Park JS; Oh CH; Park DA; Byeon JS; Lee ST; Kim HG; Chun HJ; Choi HS; Park CG; Cho JY
Clin Endosc; 2021 Mar; 54(2):161-181. PubMed ID: 33761231
[TBL] [Abstract][Full Text] [Related]
16. Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using a 20-Gauge Menghini Needle with a Lateral Forward Bevel and a 22-Gauge Franseen Needle: A Single-Center Large Cohort Study.
Mie T; Sasaki T; Kanata R; Furukawa T; Takeda T; Kasuga A; Matsuyama M; Ozaka M; Sasahira N
Clin Endosc; 2021 Sep; 54(5):730-738. PubMed ID: 33657780
[TBL] [Abstract][Full Text] [Related]
17. Utility of a 20G needle with a core trap in EUS-guided fine-needle biopsy for gastric submucosal tumors: A multicentric prospective trial.
Kamata K; Kurita A; Yasukawa S; Chiba Y; Nebiki H; Asada M; Yasuda H; Shiomi H; Ogura T; Takaoka M; Hoki N; Ashida R; Shigekawa M; Yanagisawa A; Kudo M; Kitano M
Endosc Ultrasound; 2021; 10(2):134-140. PubMed ID: 33586688
[TBL] [Abstract][Full Text] [Related]
18. A randomized noninferiority trial comparing the diagnostic yield of the 25G ProCore needle to the standard 25G needle in suspicious pancreatic lesions.
Hassan GM; Wyse JM; Paquin SC; Gariepy G; Albadine R; Mâsse B; Trottier H; Sahai AV
Endosc Ultrasound; 2021; 10(1):57-61. PubMed ID: 33402551
[TBL] [Abstract][Full Text] [Related]
19. Comparison of the reverse bevel versus Franseen type endoscopic ultrasound needle.
Chow CW; Haider SA; Ragunath K; Aithal GP; James MW; Ortiz-Fernandez-Sordo J; Aravinthan AD; Venkatachalapathy SV
World J Gastrointest Endosc; 2020 Sep; 12(9):266-275. PubMed ID: 32994857
[TBL] [Abstract][Full Text] [Related]
20. Endoscopic Ultrasound-Guided Fine Needle Biopsy Needles Provide Higher Diagnostic Yield Compared to Endoscopic Ultrasound-Guided Fine Needle Aspiration Needles When Sampling Solid Pancreatic Lesions: A Meta-Analysis.
Renelus BD; Jamorabo DS; Boston I; Briggs WM; Poneros JM
Clin Endosc; 2021 Mar; 54(2):261-268. PubMed ID: 32892519
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]