These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

270 related articles for article (PubMed ID: 27130397)

  • 1. Comparison of fixation techniques in Vancouver type AG periprosthetic femoral fracture: a biomechanical study.
    Sarıyılmaz K; Korkmaz M; Özkunt O; Gemalmaz HC; Sungur M; Baydoğan M; Kaya İ; Dikici F
    Acta Orthop Traumatol Turc; 2016; 50(3):373-8. PubMed ID: 27130397
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical evaluation of fracture fixation constructs using a variable-angle locked periprosthetic femur plate system.
    Hoffmann MF; Burgers TA; Mason JJ; Williams BO; Sietsema DL; Jones CB
    Injury; 2014 Jul; 45(7):1035-41. PubMed ID: 24680467
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Better Axial Stiffness of a Bicortical Screw Construct Compared to a Cable Construct for Comminuted Vancouver B1 Proximal Femoral Fractures.
    Griffiths JT; Taheri A; Day RE; Yates PJ
    J Arthroplasty; 2015 Dec; 30(12):2333-7. PubMed ID: 26239233
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Periprosthetic femoral fracture fixation: a biomechanical comparison between proximal locking screws and cables.
    Graham SM; Mak JH; Moazen M; Leonidou A; Jones AC; Wilcox RK; Tsiridis E
    J Orthop Sci; 2015 Sep; 20(5):875-80. PubMed ID: 25968896
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Do Transcortical Screws in a Locking Plate Construct Improve the Stiffness in the Fixation of Vancouver B1 Periprosthetic Femur Fractures? A Biomechanical Analysis of 2 Different Plating Constructs.
    Lochab J; Carrothers A; Wong E; McLachlin S; Aldebeyan W; Jenkinson R; Whyne C; Nousiainen MT
    J Orthop Trauma; 2017 Jan; 31(1):15-20. PubMed ID: 28002219
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Radiographic outcomes of cable-plate versus cable-grip fixation in periprosthetic fractures of the proximal femur.
    Ricciardi BF; Nodzo SR; Oi K; Lee YY; Westrich GH
    Hip Int; 2017 Nov; 27(6):584-588. PubMed ID: 28574126
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Managing Vancouver B1 fractures by cerclage system compared to locking plate fixation - a biomechanical study.
    Gordon K; Winkler M; Hofstädter T; Dorn U; Augat P
    Injury; 2016 Jun; 47 Suppl 2():S51-7. PubMed ID: 27338228
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Plate fixation of periprosthetic femur fractures: What happens to the cement mantle?
    Konstantinidis L; Schmidt B; Bernstein A; Hirschmüller A; Schröter S; Südkamp NP; Helwig P
    Proc Inst Mech Eng H; 2017 Feb; 231(2):138-142. PubMed ID: 28013577
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Are proximal screws necessary for osteosynthesis of stable-stem periprosthetic femoral fractures fixed with non-locking plate and cable?
    Yang TC; Tzeng YH; Wang CS; Lin CC; Chang MC; Chiang CC
    Injury; 2019 Oct; 50(10):1739-1744. PubMed ID: 31182231
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures.
    Buttaro MA; Farfalli G; Paredes Núñez M; Comba F; Piccaluga F
    J Bone Joint Surg Am; 2007 Sep; 89(9):1964-9. PubMed ID: 17768193
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Plate fixation in periprosthetic femur fractures Vancouver type B1-Trochanteric hook plate or subtrochanterical bicortical locking?
    Lenz M; Stoffel K; Kielstein H; Mayo K; Hofmann GO; Gueorguiev B
    Injury; 2016 Dec; 47(12):2800-2804. PubMed ID: 27720182
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical evaluation of periprosthetic refractures following distal femur locking plate fixation.
    Alexander J; Morris RP; Kaimrajh D; Milne E; Latta L; Flink A; Lindsey RW
    Injury; 2015 Dec; 46(12):2368-73. PubMed ID: 26553428
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Application of Far Cortical Locking Technology in Periprosthetic Femoral Fracture Fixation: A Biomechanical Study.
    Moazen M; Leonidou A; Pagkalos J; Marghoub A; Fagan MJ; Tsiridis E
    J Arthroplasty; 2016 Aug; 31(8):1849-56. PubMed ID: 26989031
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Finite element analysis of different repair methods of Vancouver B1 periprosthetic fractures after total hip arthroplasty.
    Chen DW; Lin CL; Hu CC; Wu JW; Lee MS
    Injury; 2012 Jul; 43(7):1061-5. PubMed ID: 22336128
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical evaluation of periprosthetic femoral fracture fixation.
    Zdero R; Walker R; Waddell JP; Schemitsch EH
    J Bone Joint Surg Am; 2008 May; 90(5):1068-77. PubMed ID: 18451400
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The biomechanical effect of bone quality and fracture topography on locking plate fixation in periprosthetic femoral fractures.
    Leonidou A; Moazen M; Lepetsos P; Graham SM; Macheras GA; Tsiridis E
    Injury; 2015 Feb; 46(2):213-7. PubMed ID: 25467710
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Periprosthetic fracture around a stable femoral stem treated with locking plate osteosynthesis: distal femoral locking plate alone versus with cerclage cable.
    Shin YS; Han SB
    Eur J Orthop Surg Traumatol; 2017 Jul; 27(5):623-630. PubMed ID: 28093609
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Locking compression plate versus revision-prosthesis for Vancouver type B2 periprosthetic femoral fractures after total hip arthroplasty.
    Joestl J; Hofbauer M; Lang N; Tiefenboeck T; Hajdu S
    Injury; 2016 Apr; 47(4):939-43. PubMed ID: 26872997
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A biomechanical study on proximal plate fixation techniques in periprosthetic femur fractures.
    Lenz M; Perren SM; Gueorguiev B; Richards RG; Hofmann GO; Fernandez dell'Oca A; Höntzsch D; Windolf M
    Injury; 2014 Jan; 45 Suppl 1():S71-5. PubMed ID: 24252576
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Osteosynthesis for periprosthetic supracondylar fracture above a total knee arthroplasty using a locking compression plate].
    Krbec M; Motycka J; Lunácek L; Dousa P
    Acta Chir Orthop Traumatol Cech; 2009 Dec; 76(6):473-8. PubMed ID: 20067694
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.