BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

458 related articles for article (PubMed ID: 27131831)

  • 1. Learning of speckle statistics for in vivo and noninvasive characterization of cutaneous wound regions using laser speckle contrast imaging.
    Basak K; Dey G; Mahadevappa M; Mandal M; Sheet D; Dutta PK
    Microvasc Res; 2016 Sep; 107():6-16. PubMed ID: 27131831
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of laser speckle contrast imaging with laser Doppler for assessing microvascular function.
    Tew GA; Klonizakis M; Crank H; Briers JD; Hodges GJ
    Microvasc Res; 2011 Nov; 82(3):326-32. PubMed ID: 21803051
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Visualization of perfusion changes with laser speckle contrast imaging using the method of motion history image.
    Ansari MZ; Humeau-Heurtier A; Offenhauser N; Dreier JP; Nirala AK
    Microvasc Res; 2016 Sep; 107():106-9. PubMed ID: 27321386
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reproducibility of high-resolution laser speckle contrast imaging to assess cutaneous microcirculation for wound healing monitoring in mice.
    Couturier A; Bouvet R; Cracowski JL; Roustit M
    Microvasc Res; 2022 May; 141():104319. PubMed ID: 35065086
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accuracy of laser speckle contrast imaging in the assessment of pediatric scald wounds.
    Mirdell R; Farnebo S; Sjöberg F; Tesselaar E
    Burns; 2018 Feb; 44(1):90-98. PubMed ID: 28797578
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monitoring microvascular perfusion variations with laser speckle contrast imaging using a view-based temporal template method.
    Ansari MZ; Kang EJ; Manole MD; Dreier JP; Humeau-Heurtier A
    Microvasc Res; 2017 May; 111():49-59. PubMed ID: 28065672
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Speed-resolved perfusion imaging using multi-exposure laser speckle contrast imaging and machine learning.
    Hultman M; Larsson M; Strömberg T; Fredriksson I
    J Biomed Opt; 2023 Mar; 28(3):036007. PubMed ID: 36950019
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of infrared thermography and laser speckle contrast imaging for the dynamic assessment of digital microvascular function.
    Pauling JD; Shipley JA; Raper S; Watson ML; Ward SG; Harris ND; McHugh NJ
    Microvasc Res; 2012 Mar; 83(2):162-7. PubMed ID: 21763703
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Microvascular blood flow monitoring with laser speckle contrast imaging using the generalized differences algorithm.
    Humeau-Heurtier A; Mahé G; Abraham P
    Microvasc Res; 2015 Mar; 98():54-61. PubMed ID: 25576743
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of Dynamic optical coherence tomography for non-invasive, in vivo microcirculation imaging of the skin.
    Themstrup L; Welzel J; Ciardo S; Kaestle R; Ulrich M; Holmes J; Whitehead R; Sattler EC; Kindermann N; Pellacani G; Jemec GB
    Microvasc Res; 2016 Sep; 107():97-105. PubMed ID: 27235002
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Imaging functional blood vessels by the laser speckle imaging (LSI) technique using Q-statistics of the generalized differences algorithm.
    Ansari MZ; Cabrera H; Ramírez-Miquet EE
    Microvasc Res; 2016 Sep; 107():46-50. PubMed ID: 27154269
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimisation of movement detection and artifact removal during laser speckle contrast imaging.
    Omarjee L; Signolet I; Humeau-Heutier A; Martin L; Henrion D; Abraham P
    Microvasc Res; 2015 Jan; 97():75-80. PubMed ID: 25261716
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Laser speckle contrast imaging for assessment of liver microcirculation.
    Sturesson C; Milstein DM; Post IC; Maas AM; van Gulik TM
    Microvasc Res; 2013 May; 87():34-40. PubMed ID: 23403398
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of laser speckle contrast imaging with laser Doppler perfusion imaging for tissue perfusion measurement.
    Guven G; Dijkstra A; Kuijper TM; Trommel N; van Baar ME; Topeli A; Ince C; van der Vlies CH
    Microcirculation; 2023 Jan; 30(1):e12795. PubMed ID: 36524297
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reliability of vulvar blood perfusion in women with provoked vestibulodynia using laser Doppler perfusion imaging and laser speckle imaging.
    Cyr MP; Pinard A; Dubois O; Morin M
    Microvasc Res; 2019 Jan; 121():1-6. PubMed ID: 30121222
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Application of optical flow algorithms to laser speckle imaging.
    Aminfar A; Davoodzadeh N; Aguilar G; Princevac M
    Microvasc Res; 2019 Mar; 122():52-59. PubMed ID: 30414869
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Laser Speckle Contrast Imaging of Skin Changes in Arteriovenous Malformation.
    Humeau-Heurtier A; Martin L; Bazeries P; Abraham P; Henni S
    Circ Cardiovasc Imaging; 2017 Mar; 10(3):. PubMed ID: 28264869
    [No Abstract]   [Full Text] [Related]  

  • 18. Laser speckle contrast imaging, the future DBF imaging technique for TRP target engagement biomarker assays.
    Bamps D; Macours L; Buntinx L; de Hoon J
    Microvasc Res; 2020 May; 129():103965. PubMed ID: 31812705
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Blood perfusion values of laser speckle contrast imaging and laser Doppler flowmetry: is a direct comparison possible?
    Binzoni T; Humeau-Heurtier A; Abraham P; Mahe G
    IEEE Trans Biomed Eng; 2013 May; 60(5):1259-65. PubMed ID: 23232361
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Excellent reproducibility of laser speckle contrast imaging to assess skin microvascular reactivity.
    Roustit M; Millet C; Blaise S; Dufournet B; Cracowski JL
    Microvasc Res; 2010 Dec; 80(3):505-11. PubMed ID: 20542492
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 23.