These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 27134797)

  • 1. Assessing Differences Between Results Determined According to the Guide to the Expression of Uncertainty in Measurement.
    Kacker RN; Kessel R; Sommer KD
    J Res Natl Inst Stand Technol; 2010; 115(6):453-9. PubMed ID: 27134797
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Combining Results From Multiple Evaluations of the Same Measurand.
    Kessel R; Kacker RN; Sommer KD
    J Res Natl Inst Stand Technol; 2011; 116(6):809-20. PubMed ID: 26989601
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Removing divergence of JCGM documents from the GUM ( 1993) and repairing other defects.
    Kacker RN; Kessel R; Lawrence JF
    Measurement (Lond); 2016; 88():. PubMed ID: 35528610
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The 2007 International Vocabulary of Metrology (VIM), JCGM 200:2008 [ISO/IEC Guide 99]: Meeting the need for intercontinentally understood concepts and their associated intercontinentally agreed terms.
    De Bièvre P
    Clin Biochem; 2009 Mar; 42(4-5):246-8. PubMed ID: 19863914
    [TBL] [Abstract][Full Text] [Related]  

  • 5. True value and uncertainty in the GUM.
    Kacker R
    J Phys Conf Ser; 2018; 1065(21):. PubMed ID: 35530980
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Uncertainty of Measurement: A Review of the Rules for Calculating Uncertainty Components through Functional Relationships.
    Farrance I; Frenkel R
    Clin Biochem Rev; 2012 May; 33(2):49-75. PubMed ID: 22896744
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of ISO-GUM and Monte Carlo methods for the evaluation of measurement uncertainty: application to direct cadmium measurement in water by GFAAS.
    Theodorou D; Meligotsidou L; Karavoltsos S; Burnetas A; Dassenakis M; Scoullos M
    Talanta; 2011 Feb; 83(5):1568-74. PubMed ID: 21238753
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of measurement uncertainty of glucose in clinical chemistry.
    Berçik Inal B; Koldas M; Inal H; Coskun C; Gümüs A; Döventas Y
    Ann N Y Acad Sci; 2007 Apr; 1100():223-6. PubMed ID: 17460183
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Standard technical specifications for methacholine chloride (Methacholine) bronchial challenge test (2023)].
    ; ;
    Zhonghua Jie He He Hu Xi Za Zhi; 2024 Feb; 47(2):101-119. PubMed ID: 38309959
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Folic acid supplementation and malaria susceptibility and severity among people taking antifolate antimalarial drugs in endemic areas.
    Crider K; Williams J; Qi YP; Gutman J; Yeung L; Mai C; Finkelstain J; Mehta S; Pons-Duran C; Menéndez C; Moraleda C; Rogers L; Daniels K; Green P
    Cochrane Database Syst Rev; 2022 Feb; 2(2022):. PubMed ID: 36321557
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Uncertainty in measurement: a review of monte carlo simulation using microsoft excel for the calculation of uncertainties through functional relationships, including uncertainties in empirically derived constants.
    Farrance I; Frenkel R
    Clin Biochem Rev; 2014 Feb; 35(1):37-61. PubMed ID: 24659835
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Bias in analytical chemistry: A review of selected procedures for incorporating uncorrected bias into the expanded uncertainty of analytical measurements and a graphical method for evaluating the concordance of reference and test procedures.
    Frenkel R; Farrance I; Badrick T
    Clin Chim Acta; 2019 Aug; 495():129-138. PubMed ID: 30935874
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of measurement uncertainty for the determination of triazines in groundwater from validation data.
    Linsinger TP; Führer M; Kandler W; Schuhmacher R
    Analyst; 2001 Feb; 126(2):211-6. PubMed ID: 11235105
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Uncertainty Evaluation for the Quantification of Urinary Amphetamine and 4-Hydroxyamphetamine Using Liquid Chromatography-Tandem Mass Spectrometry: Comparison of the Guide to the Expression of Uncertainty in Measurement Approach and the Monte Carlo Method with R.
    Kim SY; Shin DW; Hyun J; Kwon NH; Cheong JC; Paeng KJ; Lee J; Kim JY
    Molecules; 2023 Sep; 28(19):. PubMed ID: 37836646
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Critique of the Guide to the expression of uncertainty in measurement method of estimating and reporting uncertainty in diagnostic assays.
    Krouwer JS
    Clin Chem; 2003 Nov; 49(11):1818-21. PubMed ID: 14578312
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement uncertainty for clinical laboratories - a revision of the concept.
    Dallas Jones GR
    Clin Chem Lab Med; 2016 Aug; 54(8):1303-7. PubMed ID: 27176746
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A standard approach to measurement uncertainties for scientists and engineers in medicine.
    Gregory K; Bibbo G; Pattison JE
    Australas Phys Eng Sci Med; 2005 Jun; 28(2):131-9. PubMed ID: 16060321
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Improving Analytical Methods by Uncertainty Evaluation with the Case of Determination of Aluminum in Starch Products by ICP-MS].
    Gao RF; Gao MC; Ling R; Zhang N
    Guang Pu Xue Yu Guang Pu Fen Xi; 2016 Apr; 36(4):1211-6. PubMed ID: 30052349
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Uncertainty model for automated gunshot residue particle length measurements obtained from electron microscopy images.
    de Martins de Souza AL; Carreteiro Damasceno J; Prado CBD; Magalhães Gurgel MA; Carvalho Silva R
    J Microsc; 2023 Dec; 292(3):105-116. PubMed ID: 37753950
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement uncertainty of γ-glutamyltransferase (GGT) in human serum by four approaches using different quality assessment data.
    Zhou R; Qin Y; Yin H; Yang Y; Wang Q
    Clin Chem Lab Med; 2018 Jan; 56(2):242-248. PubMed ID: 28809749
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.