These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 2714059)

  • 41. Method for high-accuracy reflectance measurements in the 2.5-microm region.
    Richter R; Müller A
    Appl Opt; 2003 Feb; 42(6):1082-90. PubMed ID: 12617226
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Thermal emissivity of avian eggshells.
    Björn LO; Bengtson SA; Li S; Hecker C; Ullah S; Roos A; Nilsson AM
    J Therm Biol; 2016 Apr; 57():1-5. PubMed ID: 27033033
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Experimental Measurement of Emissivity of Polished Steel Strips from a Continuous Annealing Line.
    Staško Š; Jablonský G; Varga A; Dzurňák R; Kizek J
    Materials (Basel); 2024 Jun; 17(13):. PubMed ID: 38998167
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Generalized inverse matrix-exterior penalty function (GIM-EPF) algorithm for data processing of multi-wavelength pyrometer (MWP).
    Liang J; Dai L; Chen S; Gu W; Peng B; Jiang N; Song W; Xing J
    Opt Express; 2018 Oct; 26(20):25706-25720. PubMed ID: 30469668
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The Reflectance of Human Skin in the Millimeter-Wave Band.
    Owda AY; Salmon N; Casson AJ; Owda M
    Sensors (Basel); 2020 Mar; 20(5):. PubMed ID: 32182667
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Emissitivity spectra obtained from field and laboratory measurements using the temperature and emissivity separation algorithm.
    Jiménez-Muñoz JC; Sobrino JA
    Appl Opt; 2006 Sep; 45(27):7104-9. PubMed ID: 16946789
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A cool response-The influence of ambient temperature on capillary refill time.
    John RT; Henricson J; Junker J; Jonson CO; Nilsson GE; Wilhelms D; Anderson CD
    J Biophotonics; 2018 Jun; 11(6):e201700371. PubMed ID: 29384267
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Influence of thermoregulatory vasomotion and ambient temperature variation on the accuracy of core-temperature estimates by cutaneous liquid-crystal thermometers.
    Ikeda T; Sessler DI; Marder D; Xiong J
    Anesthesiology; 1997 Mar; 86(3):603-12. PubMed ID: 9066326
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [Correction method for infrared spectral emissivity measurement system based on integrating sphere reflectometer].
    Zhang YF; Dai JM; Zhang Y; Pan WD; Zhang L
    Guang Pu Xue Yu Guang Pu Fen Xi; 2013 Aug; 33(8):2267-71. PubMed ID: 24159891
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Toward an Accurate IR Remote Sensing of Body Temperature Radiometer Based on a Novel IR Sensing System Dubbed Digital TMOS.
    Avraham M; Nemirovsky J; Blank T; Golan G; Nemirovsky Y
    Micromachines (Basel); 2022 Apr; 13(5):. PubMed ID: 35630174
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Modeling the thermal responses of the skin surface during hand-object interactions.
    Ho HN; Jones LA
    J Biomech Eng; 2008 Apr; 130(2):021005. PubMed ID: 18412492
    [TBL] [Abstract][Full Text] [Related]  

  • 52. [Radiation thermometry based on calibration of spectral responsivity].
    Xin CY; Cheng XF; Zhang ZZ
    Guang Pu Xue Yu Guang Pu Fen Xi; 2012 Oct; 32(10):2735-8. PubMed ID: 23285877
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Far-infrared surface emissivity and climate.
    Feldman DR; Collins WD; Pincus R; Huang X; Chen X
    Proc Natl Acad Sci U S A; 2014 Nov; 111(46):16297-302. PubMed ID: 25368189
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Systematic errors in the measurement of emissivity caused by directional effects.
    Kribus A; Vishnevetsky I; Rotenberg E; Yakir D
    Appl Opt; 2003 Apr; 42(10):1839-46. PubMed ID: 12683764
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Circadian rhythms in bed rest: Monitoring core body temperature via heat-flux approach is superior to skin surface temperature.
    Mendt S; Maggioni MA; Nordine M; Steinach M; Opatz O; Belavý D; Felsenberg D; Koch J; Shang P; Gunga HC; Stahn A
    Chronobiol Int; 2017; 34(5):666-676. PubMed ID: 27726448
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Simultaneous measurement of temperature and emissivity of lunar regolith simulant using dual-channel millimeter-wave radiometry.
    McCloy JS; Sundaram SK; Matyas J; Woskov PP
    Rev Sci Instrum; 2011 May; 82(5):054703. PubMed ID: 21639528
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Experimental determination of the emissivity of bone.
    Feldmann A; Zysset P
    Med Eng Phys; 2016 Oct; 38(10):1136-8. PubMed ID: 27387900
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Near-infrared thermo-optical response of the localized reflectance of intact diabetic and nondiabetic human skin.
    Yeh SJ; Khalil OS; Hanna CF; Kantor S
    J Biomed Opt; 2003 Jul; 8(3):534-44. PubMed ID: 12880361
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Measurement of surface temperature and emissivity of different materials by two-colour pyrometry.
    Raj VC; Prabhu SV
    Rev Sci Instrum; 2013 Dec; 84(12):124903. PubMed ID: 24387454
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Estimation of broadband emissivity (8-12 um) from ASTER data by using RM-NN.
    Mao KB; Ma Y; Shen XY; Li BP; Li CY; Li ZL
    Opt Express; 2012 Aug; 20(18):20096-101. PubMed ID: 23037062
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.