206 related articles for article (PubMed ID: 27143792)
1. APPLICATION OF PTTL METHOD FOR DOSE REASSESSMENT IN EXTREMITY DOSIMETRY.
Sas-Bieniarz A; Budzanowski M; Bubak A; Kopeć R
Radiat Prot Dosimetry; 2016 Sep; 170(1-4):204-7. PubMed ID: 27143792
[TBL] [Abstract][Full Text] [Related]
2. The applicability of the PTTL dose re-analysis method to the Harshaw LiF:Mg,Cu,P material.
Moscovitch M; Benevides L; Romanyukha A; Hull F; Duffy M; Voss S; Velbeck KJ; Nita I; Rotunda JE
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):161-4. PubMed ID: 21450701
[TBL] [Abstract][Full Text] [Related]
3. Application of whole-body personal TL dosemeters in mixed field beta-gamma radiation.
Ciupek K; Aksamit D; Wołoszczuk K
Radiat Prot Dosimetry; 2014 Nov; 162(1-2):20-3. PubMed ID: 25009188
[TBL] [Abstract][Full Text] [Related]
4. FADING EFFECT OF LiF:Mg,Ti AND LiF:Mg,Cu,P Ext-Rad AND WHOLE-BODY DETECTORS.
Pereira J; Pereira MF; Rangel S; Saraiva M; Santos LM; Cardoso JV; Alves JG
Radiat Prot Dosimetry; 2016 Sep; 170(1-4):177-80. PubMed ID: 26503857
[TBL] [Abstract][Full Text] [Related]
5. Energy response of different types of RADOS personal dosemeters with MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) TL detectors.
Obryk B; Hranitzky C; Stadtmann H; Budzanowski M; Olko P
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):211-4. PubMed ID: 21227957
[TBL] [Abstract][Full Text] [Related]
6. UV-induced bleaching of deep traps in Harshaw TLD LiF:Mg,Cu,P and LiF:Mg,Ti.
Benevides L; Voss S; Nita I; Rotunda J; Velbeck K; Luo LZ; Moscovitch M
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):199-201. PubMed ID: 21310735
[TBL] [Abstract][Full Text] [Related]
7. Pre- and post-irradiation fading effect for LiF:Mg,Ti and LiF:Mg,Cu,P materials used in routine monitoring.
Carinou E; Askounis P; Dimitropoulou F; Kiranos G; Kyrgiakou H; Nirgianaki E; Papadomarkaki E; Kamenopoulou V
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):207-10. PubMed ID: 21199822
[TBL] [Abstract][Full Text] [Related]
8. A STUDY ON THE UNCERTAINTY FOR THE ROUTINE DOSIMETRY SERVICE AT THE LEBANESE ATOMIC ENERGY COMMISSION USING HARSHAW 8814 DOSEMETERS.
Rizk C; Vanhavere F
Radiat Prot Dosimetry; 2016 Sep; 170(1-4):168-72. PubMed ID: 26443544
[TBL] [Abstract][Full Text] [Related]
9. Dose levels of the occupational radiation exposures in Poland based on results from the accredited dosimetry service at the IFJ PAN, Krakow.
Budzanowski M; Kopeć R; Obryk B; Olko P
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):107-10. PubMed ID: 21183549
[TBL] [Abstract][Full Text] [Related]
10. On the reassessment of thermal neutron doses in TLD-100 by measuring the residual dose.
Abraham A; Weinstein M; German U; Alfassi ZB
Radiat Prot Dosimetry; 2007; 126(1-4):524-7. PubMed ID: 17507383
[TBL] [Abstract][Full Text] [Related]
11. Method of thermoluminescent measurement of radiation doses from micrograys up to a megagray with a single LiF:Mg,Cu,P detector.
Obryk B; Bilski P; Olko P
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):543-7. PubMed ID: 21051430
[TBL] [Abstract][Full Text] [Related]
12. Batch homogeneity of LiF(Mg,Cu,P)-GR200 and LiF(Mg,Cu,P)-MCP-NS TL detectors for use as extremity dosemeters at ENEA personal dosimetry service.
Mariotti F; Uleri G; Fantuzzi E
Radiat Prot Dosimetry; 2006; 120(1-4):283-8. PubMed ID: 16702241
[TBL] [Abstract][Full Text] [Related]
13. Individual monitoring in nuclear medicine therapeutic procedures using extremity dosemeters LiF(Mg, Cu, P).
Sarti G; Del Dottore F; Fabbri C; Tassinari L; Pagan S; Rustignoli M; Motta P
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):521-4. PubMed ID: 21030398
[TBL] [Abstract][Full Text] [Related]
14. A THIN-LAYER LIF THERMOLUMINESCENCE DOSEMETER SYSTEM WITH FAST READOUT FOR THE USE IN PERSONAL DOSIMETRY SERVICES.
Walbersloh J; Busch F
Radiat Prot Dosimetry; 2016 Sep; 170(1-4):191-4. PubMed ID: 26622040
[TBL] [Abstract][Full Text] [Related]
15. A whole-body dosimetry system for personal monitoring based on hot-pressed thin layer TLD.
Busch F; Engelhardt J; Martini E; Lesz J
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):246-8. PubMed ID: 21227958
[TBL] [Abstract][Full Text] [Related]
16. On the reassessment of doses in TL-dosimetry by measuring the residual dose.
Abraham A; Weinstein M; German U; Alfassi ZB
Radiat Prot Dosimetry; 2007; 125(1-4):113-6. PubMed ID: 17449909
[TBL] [Abstract][Full Text] [Related]
17. TYPE TESTING OF LiF:Mg,Cu,P (TLD-100H) WHOLE-BODY DOSEMETERS FOR THE ASSESSMENT OF Hp(10) AND Hp(0.07).
Pereira JS; Pereira MF; Rangel S; Caldeira M; Carvalhal G; Santos LM; Cardoso JV; Alves JG
Radiat Prot Dosimetry; 2019 Aug; 184(2):216-223. PubMed ID: 30496554
[TBL] [Abstract][Full Text] [Related]
18. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV).
Tedgren AC; Hedman A; Grindborg JE; Carlsson GA
Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372
[TBL] [Abstract][Full Text] [Related]
19. A system for rapid large-area monitoring of gamma dose rates in the environment based on MCP-N (LiF:Mg,Cu,P) TL detectors.
Budzanowski M; Olko P; Ryba E; Woźnicka U
Radiat Prot Dosimetry; 2002; 101(1-4):205-9. PubMed ID: 12382736
[TBL] [Abstract][Full Text] [Related]
20. Evaluating the performance of the Harshaw™ DXTRAD LiF:Mg,Cu,P finger ring with two different thickness filters.
Baker ST; Roberts GH; Gilvin PJ
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):243-5. PubMed ID: 21212080
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]