284 related articles for article (PubMed ID: 27151898)
1. Extravasation Risk Using Ultrasound-guided Peripheral Intravenous Catheters for Computed Tomography Contrast Administration.
Rupp JD; Ferre RM; Boyd JS; Dearing E; McNaughton CD; Liu D; Jarrell KL; McWade CM; Self WH
Acad Emerg Med; 2016 Aug; 23(8):918-21. PubMed ID: 27151898
[TBL] [Abstract][Full Text] [Related]
2. Risk of contrast extravasation with vascular access in computed tomography.
Stowell JR; Rigdon D; Colglazier R; Filler L; Orosco D; Connell M; Akhter M; Mitchell C
Emerg Radiol; 2020 Jun; 27(3):253-258. PubMed ID: 31919617
[TBL] [Abstract][Full Text] [Related]
3. Contrast Extravasation as a Complication of Emergency Nurse-Performed Ultrasound-Guided Peripheral Intravenous Catheter Placement.
Favot M; Gallien J; Malik A; Kasten A; Wells R; Ehrman R
J Emerg Nurs; 2019 Sep; 45(5):512-516. PubMed ID: 31445627
[TBL] [Abstract][Full Text] [Related]
4. Incidence of intravenous contrast extravasation: increased risk for patients with deep brachial catheter placement from the emergency department.
Hardie AD; Kereshi B
Emerg Radiol; 2014 Jun; 21(3):235-8. PubMed ID: 24395398
[TBL] [Abstract][Full Text] [Related]
5. Risk Factors for Contrast Media Extravasation in Intravenous Contrast-Enhanced Computed Tomography: An Observational Cohort Study.
Liu W; Wang P; Zhu H; Tang H; Wang X; Guan H; Wang C; Qiu Y; Peng A; He L
Acad Radiol; 2024 May; 31(5):1792-1798. PubMed ID: 38307790
[TBL] [Abstract][Full Text] [Related]
6. Prospective study of access site complications of automated contrast injection with peripheral venous access in MDCT.
Wienbeck S; Fischbach R; Kloska SP; Seidensticker P; Osada N; Heindel W; Juergens KU
AJR Am J Roentgenol; 2010 Oct; 195(4):825-9. PubMed ID: 20858804
[TBL] [Abstract][Full Text] [Related]
7. Frequency, outcome, and risk factors of contrast media extravasation in 142,651 intravenous contrast-enhanced CT scans.
Hwang EJ; Shin CI; Choi YH; Park CM
Eur Radiol; 2018 Dec; 28(12):5368-5375. PubMed ID: 29876706
[TBL] [Abstract][Full Text] [Related]
8. Alternative vascular device for high-flow computed tomography angiography: ultrasound-guided long peripheral catheter (4 Fr × 10 cm).
Watts-Pajaro F; Uribe-Buritica FL
J Vasc Access; 2021 Mar; 22(2):288-291. PubMed ID: 32633189
[TBL] [Abstract][Full Text] [Related]
9. Power Injection Through Ultrasound-Guided Intravenous Lines: Safety and Efficacy Under an Institutional Protocol.
Witting MD; Moayedi S; Dunning K; Babin LS; Cogan BM
J Emerg Med; 2017 Jan; 52(1):16-22. PubMed ID: 27765438
[TBL] [Abstract][Full Text] [Related]
10. Extended dwell and standard ultrasound guided peripheral intravenous catheters: Comparison of durability and reliability.
Fung CM; Stayer DR; Terrasi JJ; Shankar PR; Cranford JA; Cover MT; Tucker RV; Huang RD; Theyyunni N
Am J Emerg Med; 2021 Sep; 47():267-273. PubMed ID: 33989915
[TBL] [Abstract][Full Text] [Related]
11. Ultrasound-guided peripheral intravenous access program is associated with a marked reduction in central venous catheter use in noncritically ill emergency department patients.
Shokoohi H; Boniface K; McCarthy M; Khedir Al-tiae T; Sattarian M; Ding R; Liu YT; Pourmand A; Schoenfeld E; Scott J; Shesser R; Yadav K
Ann Emerg Med; 2013 Feb; 61(2):198-203. PubMed ID: 23141920
[TBL] [Abstract][Full Text] [Related]
12. Safe use of power injectors with central and peripheral venous access devices for pediatric CT.
Kaste SC; Young CW
Pediatr Radiol; 1996; 26(8):499-501. PubMed ID: 8753658
[TBL] [Abstract][Full Text] [Related]
13. A Standardized Training Program in Ultrasound-Guided Intravenous Line Placement: Improving Nurses' Confidence and Success.
McKinney A; Steanson K; Lebar K
Adv Neonatal Care; 2023 Feb; 23(1):17-22. PubMed ID: 35170498
[TBL] [Abstract][Full Text] [Related]
14. Derivation of a clinical decision-making aid to improve the insertion of clinically indicated peripheral intravenous catheters and promote vessel health preservation. An observational study.
Carr PJ; Rippey JCR; Cooke ML; Higgins NS; Trevenen ML; Foale A; Keijzers G; Rickard CM
PLoS One; 2019; 14(3):e0213923. PubMed ID: 30901370
[TBL] [Abstract][Full Text] [Related]
15. Factors associated with intraoperative intravenous catheter extravasation in children.
Mecoli MD; Ding L; Yang G; McSoley JW; Doellman DA; Rineair SA; Subramanyam R
Anaesth Intensive Care; 2022 Jul; 50(4):306-311. PubMed ID: 35277085
[TBL] [Abstract][Full Text] [Related]
16. Nurse-focused ultrasound-guided IV program improves core emergency department process measures.
Kessler R; Hall J; Chipman AK; Hall MK; Amick A
J Vasc Access; 2024 Feb; ():11297298241230109. PubMed ID: 38372249
[TBL] [Abstract][Full Text] [Related]
17. Difficult Intravenous Access Requiring Ultrasound in the Emergency Department: Associations With Delays in Care and Areas for Quality Improvement.
Huang D; Winter L; Macauley E; Alterman T; Renouard B; Wilson JL; Leon LN
Cureus; 2023 Sep; 15(9):e44960. PubMed ID: 37822433
[TBL] [Abstract][Full Text] [Related]
18. A systematic review of extravasation and local tissue injury from administration of vasopressors through peripheral intravenous catheters and central venous catheters.
Loubani OM; Green RS
J Crit Care; 2015 Jun; 30(3):653.e9-17. PubMed ID: 25669592
[TBL] [Abstract][Full Text] [Related]
19. Power-injectable ports: safety during placement, therapeutic use, and contrast administration during computed tomography procedures.
Alexander MD; Morrison HL
J Vasc Access; 2012; 13(4):432-7. PubMed ID: 22610789
[TBL] [Abstract][Full Text] [Related]
20. Implications of iodinated contrast media extravasation in the emergency department.
Sonis JD; Gottumukkala RV; Glover M; Yun BJ; White BA; Kalra MK; Otrakji A; Raja AS; Prabhakar AM
Am J Emerg Med; 2018 Feb; 36(2):294-296. PubMed ID: 29137904
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]