  • 61. A Review of Reported Adverse Events in MRI-Safe and MRI-Conditional Cochlear Implants.
    Bestourous DE; Davidson L; Reilly BK
    Otol Neurotol; 2022 Jan; 43(1):42-47. PubMed ID: 34510115
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Skin flap thickness and magnet strength in Cochlear implants.
    Searle T; Marshall E; Craddock L; Monksfield P
    Cochlear Implants Int; 2021 Mar; 22(2):80-84. PubMed ID: 32993474
    [No Abstract]   [Full Text] [Related]  

  • 63. MRI Artifacts and Cochlear Implant Positioning at 3 T In Vivo.
    Todt I; Rademacher G; Mittmann P; Wagner J; Mutze S; Ernst A
    Otol Neurotol; 2015 Jul; 36(6):972-6. PubMed ID: 25634466
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Radiologic recognition of cochlear implant magnet displacement.
    Epperson MV; Born HL; Greinwald J
    Int J Pediatr Otorhinolaryngol; 2019 May; 120():64-67. PubMed ID: 30771555
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Special Considerations in Patients with Cranial Neurostimulatory Implants.
    Wickemeyer JL; Sharon JD; Weinreich HM
    Otolaryngol Clin North Am; 2020 Feb; 53(1):57-71. PubMed ID: 31685238
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Magnet and receiver-stimulator displacement after cochlear implantation: Clinical characters and management approaches.
    Alahmadi A; Alenzi S; Alsheikh M; Alghamdi S; Morra ME; Badr KM
    Saudi Med J; 2021 Aug; 42(8):813-824. PubMed ID: 34344804
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Effect of head position on cochlear implant MRI artifact.
    Ay N; Gehl HB; Sudhoff H; Todt I
    Eur Arch Otorhinolaryngol; 2021 Aug; 278(8):2763-2767. PubMed ID: 32909061
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Rationing Rotational Magnet Cochlear Implant Technology in a Single Payer Healthcare System.
    Pisa J; Andrews C; Hochman JB
    Ann Otol Rhinol Laryngol; 2021 Aug; 130(8):868-872. PubMed ID: 32698602
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Safety of 3 Tesla Magnetic Resonance Imaging in Patients With Auditory Brainstem Implants.
    Wichova H; Peng K; Ledbetter L; Slattery W; Brackmann D; Lekovic G
    Otol Neurotol; 2022 Feb; 43(2):e263-e267. PubMed ID: 34855679
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Significant Artifact Reduction at 1.5T and 3T MRI by the Use of a Cochlear Implant with Removable Magnet: An Experimental Human Cadaver Study.
    Wagner F; Wimmer W; Leidolt L; Vischer M; Weder S; Wiest R; Mantokoudis G; Caversaccio MD
    PLoS One; 2015; 10(7):e0132483. PubMed ID: 26200775
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Dimensions of artefacts caused by cochlear and auditory brainstem implants in magnetic resonance imaging.
    Majdani E; Majdani O; Steffens M; Warnecke A; Lesinski-Schiedat A; Lenarz T; Götz F
    Cochlear Implants Int; 2020 Mar; 21(2):67-74. PubMed ID: 31553273
    [No Abstract]   [Full Text] [Related]  

  • 72. A Systematic Review of Cochlear Implant-Related Magnetic Resonance Imaging Artifact: Implications for Clinical Imaging.
    Berry JM; Tansey JB; Wu L; Choudhri A; Yawn RJ; MacDonald CB; Richard C
    Otol Neurotol; 2024 Mar; 45(3):204-214. PubMed ID: 38260952
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Case report: traumatic displacement of a cochlear implant magnet.
    Keereweer S; Van der Schroeff MP; Pullens B
    Ann Otol Rhinol Laryngol; 2014 Apr; 123(4):229-31. PubMed ID: 24671476
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Magnetic resonance imaging compatibility testing of the Clarion 1.2 cochlear implant.
    Weber BP; Goldring JE; Santogrossi T; Koestler H; Tziviskos G; Battmer R; Lenarz Th
    Am J Otol; 1998 Sep; 19(5):584-90. PubMed ID: 9752965
    [TBL] [Abstract][Full Text] [Related]  

  • 75. [Magnetic resonance imaging in patients with magnetic hearing implants: overview and procedural management].
    Nospes S; Mann W; Keilmann A
    Radiologe; 2013 Nov; 53(11):1026-32. PubMed ID: 24113904
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Noninvasive management of cochlear implant's inner magnet displacement after magnetic resonance.
    Di Nardo W; Giannantonio S; Schinaia L; De Corso E; Paludetti G
    Laryngoscope; 2013 Mar; 123(3):783-6. PubMed ID: 23086709
    [TBL] [Abstract][Full Text] [Related]  

  • 77. [MRI in patients with a cochlear implant: how to proceed].
    de Vos B; Ziylan F; Sanchez E; Smits C; Merkus P
    Ned Tijdschr Geneeskd; 2019 May; 163():. PubMed ID: 31120210
    [TBL] [Abstract][Full Text] [Related]  

  • 78. The role of cochlear implant positioning on MR imaging quality: a preclinical in vivo study with a novel implant magnet system.
    Canzi P; Magnetto M; Simoncelli A; Manfrin M; Aprile F; Lafe E; Carlotto E; Avato I; Scribante A; Preda L; Benazzo M
    Eur Arch Otorhinolaryngol; 2022 Jun; 279(6):2889-2898. PubMed ID: 34370074
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Magnet displacement: a rare complication following cochlear implantation.
    Wild C; Allum J; Probst R; Abels D; Fischer C; Bodmer D
    Eur Arch Otorhinolaryngol; 2010 Jan; 267(1):57-9. PubMed ID: 19562363
    [TBL] [Abstract][Full Text] [Related]  

  • 80. MR Imaging and Cochlear Implants with Retained Internal Magnets: Reducing Artifacts near Highly Inhomogeneous Magnetic Fields.
    Edmonson HA; Carlson ML; Patton AC; Watson RE
    Radiographics; 2018; 38(1):94-106. PubMed ID: 29320320
    [TBL] [Abstract][Full Text] [Related]  