360 related articles for article (PubMed ID: 27157630)
1. Can customized implants correct enophthalmos and delayed diplopia in post-traumatic orbital deformities? A volumetric analysis.
Pedemonte C; Sáez F; Vargas I; González LE; Canales M; Salazar K
Int J Oral Maxillofac Surg; 2016 Sep; 45(9):1086-94. PubMed ID: 27157630
[TBL] [Abstract][Full Text] [Related]
2. Customized titanium reconstruction of post-traumatic orbital wall defects: a review of 22 cases.
Mustafa SF; Evans PL; Bocca A; Patton DW; Sugar AW; Baxter PW
Int J Oral Maxillofac Surg; 2011 Dec; 40(12):1357-62. PubMed ID: 21885249
[TBL] [Abstract][Full Text] [Related]
3. Virtual surgery simulation in orbital wall reconstruction: integration of surgical navigation and stereolithographic models.
Novelli G; Tonellini G; Mazzoleni F; Bozzetti A; Sozzi D
J Craniomaxillofac Surg; 2014 Dec; 42(8):2025-34. PubMed ID: 25458348
[TBL] [Abstract][Full Text] [Related]
4. Individual design and rapid prototyping in reconstruction of orbital wall defects.
Tang W; Guo L; Long J; Wang H; Lin Y; Liu L; Tian W
J Oral Maxillofac Surg; 2010 Mar; 68(3):562-70. PubMed ID: 20171476
[TBL] [Abstract][Full Text] [Related]
5. Generation of customized orbital implant templates using 3-dimensional printing for orbital wall reconstruction.
Kang S; Kwon J; Ahn CJ; Esmaeli B; Kim GB; Kim N; Sa HS
Eye (Lond); 2018 Dec; 32(12):1864-1870. PubMed ID: 30154573
[TBL] [Abstract][Full Text] [Related]
6. Technical concept of patient-specific, ultrahigh molecular weight polyethylene orbital wall implant.
Kozakiewicz M; Elgalal M; Walkowiak B; Stefanczyk L
J Craniomaxillofac Surg; 2013 Jun; 41(4):282-90. PubMed ID: 23333489
[TBL] [Abstract][Full Text] [Related]
7. Correction of Delayed Traumatic Enophthalmos Using Customized Orbital Implants.
Pedemonte Trewhela C; Díaz Reiher M; Muñoz Zavala T; González Mora LE; Vargas Farren I
J Oral Maxillofac Surg; 2018 Sep; 76(9):1937-1945. PubMed ID: 29654775
[TBL] [Abstract][Full Text] [Related]
8. Three dimensional reconstruction of late post traumatic orbital wall defects by customized implants using CAD-CAM, 3D stereolithographic models: A case report.
U V; Mehrotra D; Dichen ; Anand V; Howlader D
J Oral Biol Craniofac Res; 2017; 7(3):212-218. PubMed ID: 29124002
[TBL] [Abstract][Full Text] [Related]
9. Computer-assisted planning, stereolithographic modeling, and intraoperative navigation for complex orbital reconstruction: a descriptive study in a preliminary cohort.
Bell RB; Markiewicz MR
J Oral Maxillofac Surg; 2009 Dec; 67(12):2559-70. PubMed ID: 19925972
[TBL] [Abstract][Full Text] [Related]
10. Accuracy of Orbital Shape Reconstruction-Comparative Analysis of Errors in Implant Shape Versus Implant Positioning: A Cadaveric Study.
Hardisty M; Wei YT; Hontscharuk R; Ibrahimi A; Antonyshyn O; Edwards G; Mainprize JG; Whyne CM
J Craniofac Surg; 2023 Sep; 34(6):1727-1731. PubMed ID: 37552131
[TBL] [Abstract][Full Text] [Related]
11. Customized Titanium Mesh Based on the 3D Printed Model vs. Manual Intraoperative Bending of Titanium Mesh for Reconstructing of Orbital Bone Fracture: A Randomized Clinical Trial.
Raisian S; Fallahi HR; Khiabani KS; Heidarizadeh M; Azdoo S
Rev Recent Clin Trials; 2017; 12(3):154-158. PubMed ID: 28828975
[TBL] [Abstract][Full Text] [Related]
12. Treatment of orbital fractures - a critical analysis of ophthalmic outcomes and scenarios for re-intervention.
Persson AAE; Lif HM; Falk-Delgado A; Nowinski D
J Plast Surg Hand Surg; 2023 May; 58():1-7. PubMed ID: 37191355
[TBL] [Abstract][Full Text] [Related]
13. Customized orbital implant versus 3D preformed titanium mesh for orbital fracture repair: A retrospective comparative analysis of orbital reconstruction accuracy.
Consorti G; Betti E; Catarzi L
J Craniomaxillofac Surg; 2024 Apr; 52(4):532-537. PubMed ID: 38368208
[TBL] [Abstract][Full Text] [Related]
14. Three-dimensional (3D) printing for post-traumatic orbital reconstruction, a systematic review and meta-analysis.
Murray-Douglass A; Snoswell C; Winter C; Harris R
Br J Oral Maxillofac Surg; 2022 Nov; 60(9):1176-1183. PubMed ID: 35931592
[TBL] [Abstract][Full Text] [Related]
15. Porous polyethylene implants in orbital blow-out fractures and enophthalmos reconstruction.
Xu JJ; Teng L; Jin XL; Ji Y; Lu JJ; Zhang B
J Craniofac Surg; 2009 May; 20(3):918-20. PubMed ID: 19480046
[TBL] [Abstract][Full Text] [Related]
16. Orbital Bony Reconstruction With Presized and Precontoured Porous Polyethylene-Titanium Implants.
Blessing NW; Rong AJ; Tse BC; Erickson BP; Lee BW; Johnson TE
Ophthalmic Plast Reconstr Surg; 2021 May-Jun 01; 37(3):284-289. PubMed ID: 32976336
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of the application of computer-aided shape-adapted fabricated titanium mesh for mirroring-reconstructing orbital walls in cases of late post-traumatic enophthalmos.
Zhang Y; He Y; Zhang ZY; An JG
J Oral Maxillofac Surg; 2010 Sep; 68(9):2070-5. PubMed ID: 20605306
[TBL] [Abstract][Full Text] [Related]
18. Orbital Reconstruction: Patient-Specific Orbital Floor Reconstruction Using a Mirroring Technique and a Customized Titanium Mesh.
Tarsitano A; Badiali G; Pizzigallo A; Marchetti C
J Craniofac Surg; 2016 Oct; 27(7):1822-1825. PubMed ID: 27438454
[TBL] [Abstract][Full Text] [Related]
19. Application of Computer-Aided Designing and Rapid Prototyping Technologies in Reconstruction of Blowout Fractures of the Orbital Floor.
Tabaković SZ; Konstantinović VS; Radosavljević R; Movrin D; Hadžistević M; Hatab N
J Craniofac Surg; 2015 Jul; 26(5):1558-63. PubMed ID: 26125649
[TBL] [Abstract][Full Text] [Related]
20. Late Reconstruction of the Orbit With Patient-Specific Implants Using Computer-Aided Planning and Navigation.
Baumann A; Sinko K; Dorner G
J Oral Maxillofac Surg; 2015 Dec; 73(12 Suppl):S101-6. PubMed ID: 26608137
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]