BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

292 related articles for article (PubMed ID: 27159858)

  • 1. The Value of Radionuclide Bone Imaging in Defining Fresh Fractures Among Osteoporotic Vertebral Compression Fractures.
    Zhao QM; Gu XF; Liu ZT; Cheng L
    J Craniofac Surg; 2016 May; 27(3):745-8. PubMed ID: 27159858
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Usefulness of MRI in determining the appropriate level of cement augmentation for acute osteoporotic vertebral compression fractures.
    Park SY; Lee SH; Suh SW; Park JH; Kim TG
    J Spinal Disord Tech; 2013 May; 26(3):E80-5. PubMed ID: 23619191
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Outcomes of Augmentation in Osteoporotic Vertebral Compression Fractures Showing a Cleft Sign on MRI.
    Tang J; Liu J; Gu Z; Song B
    Cardiovasc Intervent Radiol; 2021 Mar; 44(3):428-435. PubMed ID: 33388869
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of high-viscosity cement vertebroplasty and balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures.
    Wang CH; Ma JZ; Zhang CC; Nie L
    Pain Physician; 2015; 18(2):E187-94. PubMed ID: 25794218
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of the painful level in osteoporotic vertebral fractures--Retrospective comparison between plain film, bone scan, and magnetic resonance imaging.
    Lin HH; Chou PH; Wang ST; Yu JK; Chang MC; Liu CL
    J Chin Med Assoc; 2015 Dec; 78(12):714-8. PubMed ID: 26364958
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Long-term follow-up study of osteoporotic vertebral compression fracture treated using balloon kyphoplasty and vertebroplasty.
    Liu JT; Li CS; Chang CS; Liao WJ
    J Neurosurg Spine; 2015 Jul; 23(1):94-8. PubMed ID: 25884343
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Effectiveness of long segment fixation combined with vertebroplasty for severe osteoporotic thoracolumbar compressive fractures].
    Xu Z; Xu W; Wang C; Luo H; Li G; Chen R
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Nov; 27(11):1331-7. PubMed ID: 24501892
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evolution of bone mineral density after percutaneous kyphoplasty in fresh osteoporotic vertebral body fractures and adjacent vertebrae along with sagittal spine alignment.
    Korovessis P; Zacharatos S; Repantis T; Michael A; Karachalios D
    J Spinal Disord Tech; 2008 Jun; 21(4):293-8. PubMed ID: 18525491
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Influence on adjacent lumbar bone density after strengthening of T12, L1 segment vertebral osteoporotic compression fracture by percutaneous vertebroplasty and percutaneous kyphoplasty].
    Zhang C; Zhu K; Zhou J; Zhou X; Niu G; Wu M; Shao C
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Jul; 27(7):819-23. PubMed ID: 24063170
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cement Leakage in Percutaneous Vertebral Augmentation for Osteoporotic Vertebral Compression Fractures: Analysis of Risk Factors.
    Xie W; Jin D; Ma H; Ding J; Xu J; Zhang S; Liang D
    Clin Spine Surg; 2016 May; 29(4):E171-6. PubMed ID: 25469491
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Correlation analysis of cement leakage with volume ratio of intravertebral bone cement to vertebral body and vertebral body wall incompetence in percutaneous vertebroplasty for osteoporotic vertebral compression fractures].
    Liang D; Ye L; Jiang X; Huang W; Yao Z; Tang Y; Zhang S; Jin D
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Nov; 28(11):1358-63. PubMed ID: 25639050
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Correlation analysis between the magnetic resonance imaging characteristics of osteoporotic vertebral compression fractures and the efficacy of percutaneous vertebroplasty: a prospective cohort study.
    Xu W; Wang S; Chen C; Li Y; Ji Y; Zhu X; Li Z
    BMC Musculoskelet Disord; 2018 Apr; 19(1):114. PubMed ID: 29650014
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The existence of intravertebral cleft impact on outcomes of nonacute osteoporotic vertebral compression fractures patients treated by percutaneous kyphoplasty: a comparative study.
    Wu AM; Lin ZK; Ni WF; Chi YL; Xu HZ; Wang XY; Huang QS
    J Spinal Disord Tech; 2014 May; 27(3):E88-93. PubMed ID: 23563348
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A biomechanical investigation of vertebroplasty in osteoporotic compression fractures and in prophylactic vertebral reinforcement.
    Furtado N; Oakland RJ; Wilcox RK; Hall RM
    Spine (Phila Pa 1976); 2007 Aug; 32(17):E480-7. PubMed ID: 17762281
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cortical screw trajectory for instrumentation and fusion in the setting of osteopathic compression fracture allows for percutaneous kyphoplasty for adjacent level compression fractures.
    Pacione D; Kim I; Wilson TA; Frempong-Boadu A
    J Clin Neurosci; 2015 May; 22(5):899-904. PubMed ID: 25724313
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use and evaluation of a semi-permeable mesh implant in vertebral augmentation for the treatment of painful osteoporotic vertebral compression fractures.
    Ortiz AO
    J Neurointerv Surg; 2016 Mar; 8(3):328-32. PubMed ID: 25586503
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Adjacent vertebral fractures after percutaneous vertebral augmentation of osteoporotic vertebral compression fracture: a comparison of balloon kyphoplasty and vertebroplasty.
    Movrin I; Vengust R; Komadina R
    Arch Orthop Trauma Surg; 2010 Sep; 130(9):1157-66. PubMed ID: 20449750
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Value of bone scan imaging in determining painful vertebrae of osteoporotic vertebral compression fractures patients with contraindications to MRI.
    Tang ZB; Lei Z; Yang HL; Chen KW
    Orthop Surg; 2012 Aug; 4(3):172-6. PubMed ID: 22927151
    [TBL] [Abstract][Full Text] [Related]  

  • 19. What are the predictors of clinical success after percutaneous vertebroplasty for osteoporotic vertebral fractures?
    Denoix E; Viry F; Ostertag A; Parlier-Cuau C; Laredo JD; Cohen-Solal M; Bousson V; Funck-Brentano T
    Eur Radiol; 2018 Jul; 28(7):2735-2742. PubMed ID: 29426990
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Analysis of the reason of secondary fracture after percutaneous vertebroplasty for osteoporotic vertebral compression fractures].
    Qin DA; Song JF; Wei J; Shao JK
    Zhongguo Gu Shang; 2014 Sep; 27(9):730-3. PubMed ID: 25571654
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.