These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

81 related articles for article (PubMed ID: 27159919)

  • 1. Comparing the viscoelastomeric fibrin polymerization assays FIBTEM® (ROTEM) vs. Functional Fibrinogen® (TEG): or why is a higher threshold for fibrinogen substitution better than a lower one?
    Schöchl H; Grottke O; Maegele M
    Clin Chem Lab Med; 2016 Sep; 54(9):e275-6. PubMed ID: 27159919
    [No Abstract]   [Full Text] [Related]  

  • 2. Reply to: Comparing the visco-elastomeric fibrin polymerization assays FIBTEM® (ROTEM) vs. Functional Fibrinogen® (TEG): or why is a higher threshold for fibrinogen substitution better than a lower one? By Schöchl et al.
    Prüller F; Mangge H
    Clin Chem Lab Med; 2016 Sep; 54(9):e277. PubMed ID: 27394045
    [No Abstract]   [Full Text] [Related]  

  • 3. Comparison of whole blood fibrin-based clot tests in thrombelastography and thromboelastometry.
    Solomon C; Sørensen B; Hochleitner G; Kashuk J; Ranucci M; Schöchl H
    Anesth Analg; 2012 Apr; 114(4):721-30. PubMed ID: 22314689
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of functional fibrinogen (FF/CFF) and FIBTEM in surgical patients - a retrospective study.
    Prüller F; Münch A; Preininger A; Raggam RB; Grinschgl Y; Krumnikl J; Toller W; Metzler H; Mahla E; Mangge H
    Clin Chem Lab Med; 2016 Mar; 54(3):453-8. PubMed ID: 26351930
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of Selected ROTEM Parameters, Kinetics of Fibrinogen Polymerization and Plasmin Amidolytic Activity in Patients with Congenital Fibrinogen Defects.
    Treliński J; Pachniewska K; Matczak J; Robak M; Chojnowski K
    Adv Clin Exp Med; 2016; 25(6):1255-1263. PubMed ID: 28028981
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The impact of hematocrit on fibrin clot formation assessed by rotational thromboelastometry.
    Ogawa S; Szlam F; Bolliger D; Nishimura T; Chen EP; Tanaka KA
    Anesth Analg; 2012 Jul; 115(1):16-21. PubMed ID: 22467887
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparison of fibrinogen measurement methods with fibrin clot elasticity assessed by thromboelastometry, before and after administration of fibrinogen concentrate in cardiac surgery patients.
    Solomon C; Cadamuro J; Ziegler B; Schöchl H; Varvenne M; Sørensen B; Hochleitner G; Rahe-Meyer N
    Transfusion; 2011 Aug; 51(8):1695-706. PubMed ID: 21352237
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of standard fibrinogen measurement methods with fibrin clot firmness assessed by thromboelastometry in patients with cirrhosis.
    Vucelic D; Jesic R; Jovicic S; Zivotic M; Grubor N; Trajkovic G; Canic I; Elezovic I; Antovic A
    Thromb Res; 2015 Jun; 135(6):1124-30. PubMed ID: 25900310
    [TBL] [Abstract][Full Text] [Related]  

  • 9. FIBTEM PLUS provides an improved thromboelastometry test for measurement of fibrin-based clot quality in cardiac surgery patients.
    Solomon C; Baryshnikova E; Schlimp CJ; Schöchl H; Asmis LM; Ranucci M
    Anesth Analg; 2013 Nov; 117(5):1054-62. PubMed ID: 24108255
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Thromboelastometric maximum clot firmness in platelet-free plasma is influenced by the assay used.
    Schlimp CJ; Solomon C; Hochleitner G; Zipperle J; Redl H; Schöchl H
    Anesth Analg; 2013 Jul; 117(1):23-9. PubMed ID: 23733839
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The influence of laboratory coagulation tests and clotting factor levels on Rotation Thromboelastometry (ROTEM(R)) during major surgery with hemorrhage.
    Theusinger OM; Schröder CM; Eismon J; Emmert MY; Seifert B; Spahn DR; Baulig W
    Anesth Analg; 2013 Aug; 117(2):314-21. PubMed ID: 23780419
    [TBL] [Abstract][Full Text] [Related]  

  • 12. High haematocrit in cyanotic congenital heart disease affects how fibrinogen activity is determined by rotational thromboelastometry.
    Westbury SK; Lee K; Reilly-Stitt C; Tulloh R; Mumford AD
    Thromb Res; 2013 Aug; 132(2):e145-51. PubMed ID: 23906940
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transfusion triggers in orthotopic liver transplantation: a comparison of the thromboelastometry analyzer, the thromboelastogram, and conventional coagulation tests.
    Coakley M; Reddy K; Mackie I; Mallett S
    J Cardiothorac Vasc Anesth; 2006 Aug; 20(4):548-53. PubMed ID: 16884987
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evidence that catalytically-inactivated thrombin forms non-covalently linked dimers that bridge between fibrin/fibrinogen fibers and enhance fibrin polymerization.
    Mosesson MW; Hernandez I; Siebenlist KR
    Biophys Chem; 2004 Jul; 110(1-2):93-100. PubMed ID: 15223147
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fibrinogen function after severe burn injury.
    Schaden E; Hoerburger D; Hacker S; Kraincuk P; Baron DM; Kozek-Langenecker S
    Burns; 2012 Feb; 38(1):77-82. PubMed ID: 22113102
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Similarities in thromboelastometric (ROTEM®) findings between humans and baboons.
    Schöchl H; Solomon C; Laux V; Heitmeier S; Bahrami S; Redl H
    Thromb Res; 2012 Sep; 130(3):e107-12. PubMed ID: 22482831
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparative evaluation of rotation thromboelastometry and standard coagulation tests in hemodilution-induced coagulation changes after cardiac surgery.
    Ogawa S; Szlam F; Chen EP; Nishimura T; Kim H; Roback JD; Levy JH; Tanaka KA
    Transfusion; 2012 Jan; 52(1):14-22. PubMed ID: 21756263
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Platelet reactivity in thromboelastometry. Revision of the FIBTEM test: a basic study.
    Biolik G; Kokot M; Sznapka M; Święszek A; Ziaja D; Pawlicki K; Ziaja K
    Scand J Clin Lab Invest; 2017 May; 77(3):216-222. PubMed ID: 28276730
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rapid and correct prediction of thrombocytopenia and hypofibrinogenemia with rotational thromboelastometry in cardiac surgery.
    Olde Engberink RH; Kuiper GJ; Wetzels RJ; Nelemans PJ; Lance MD; Beckers EA; Henskens YM
    J Cardiothorac Vasc Anesth; 2014 Apr; 28(2):210-6. PubMed ID: 24630470
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clot Formation Is Associated With Fibrinogen and Platelet Forces in a Cohort of Severely Injured Emergency Department Trauma Patients.
    White NJ; Newton JC; Martin EJ; Mohammed BM; Contaifer D; Bostic JL; Brophy GM; Spiess BD; Pusateri AE; Ward KR; Brophy DF
    Shock; 2015 Aug; 44 Suppl 1(0 1):39-44. PubMed ID: 25643013
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.