These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

242 related articles for article (PubMed ID: 27160558)

  • 21. Effect of low-friction ion-treated femoral heads on polyethylene wear rates.
    Maruyama M; Capello WN; D'Antonio JA; Jaffe WL; Bierbaum BE
    Clin Orthop Relat Res; 2000 Jan; (370):183-91. PubMed ID: 10660712
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of wear of bearing surfaces on elastohydrodynamic lubrication of metal-on-metal hip implants.
    Liu F; Jin ZM; Hirt F; Rieker C; Roberts P; Grigoris P
    Proc Inst Mech Eng H; 2005 Sep; 219(5):319-28. PubMed ID: 16225148
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Innovative tribometer for in situ spectroscopic analyses of wear mechanisms and phase transformation in ceramic femoral heads.
    Puppulin L; Leto A; Wenliang Z; Sugano N; Pezzotti G
    J Mech Behav Biomed Mater; 2014 Mar; 31():45-54. PubMed ID: 23453272
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The effect of 'running-in' on the tribology and surface morphology of metal-on-metal Birmingham hip resurfacing device in simulator studies.
    Vassiliou K; Elfick AP; Scholes SC; Unsworth A
    Proc Inst Mech Eng H; 2006 Feb; 220(2):269-77. PubMed ID: 16669393
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Friction of total hip replacements with different bearings and loading conditions.
    Brockett C; Williams S; Jin Z; Isaac G; Fisher J
    J Biomed Mater Res B Appl Biomater; 2007 May; 81(2):508-15. PubMed ID: 17041924
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of swing phase load on metal-on-metal hip lubrication, friction and wear.
    Williams S; Jalali-Vahid D; Brockett C; Jin Z; Stone MH; Ingham E; Fisher J
    J Biomech; 2006; 39(12):2274-81. PubMed ID: 16143337
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Large Metal Heads and Vitamin E Polyethylene Increase Frictional Torque in Total Hip Arthroplasty.
    Meneghini RM; Lovro LR; Wallace JM; Ziemba-Davis M
    J Arthroplasty; 2016 Mar; 31(3):710-4. PubMed ID: 26482682
    [TBL] [Abstract][Full Text] [Related]  

  • 28. How do alternative bearing surfaces influence wear behavior?
    Clarke IC; Manley MT;
    J Am Acad Orthop Surg; 2008; 16 Suppl 1():S86-93. PubMed ID: 18612022
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Compatibility of the totally replaced hip. Reduction of wear by amorphous diamond coating.
    Santavirta S
    Acta Orthop Scand Suppl; 2003 Dec; 74(310):1-19. PubMed ID: 14768485
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Wear and surface analysis of 38 mm ceramic-on-metal total hip replacements under standard and severe wear testing conditions.
    Williams SR; Wu JJ; Unsworth A; Khan I
    Proc Inst Mech Eng H; 2011 Aug; 225(8):783-96. PubMed ID: 21922955
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Integrated friction measurements in hip wear simulations: short-term results.
    Spinelli M; Affatato S; Tiberi L; Carmignato S; Viceconti M
    Proc Inst Mech Eng H; 2010; 224(7):865-76. PubMed ID: 20839654
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Friction and wear properties of polymer, metal, and ceramic prosthetic joint materials evaluated on a multichannel screening device.
    McKellop H; Clarke I; Markolf K; Amstutz H
    J Biomed Mater Res; 1981 Sep; 15(5):619-53. PubMed ID: 12659132
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Effect of wear, acetabular cup inclination angle, load and serum degradation on the friction of a large diameter metal-on-metal hip prosthesis.
    Saikko V
    Clin Biomech (Bristol, Avon); 2019 Mar; 63():1-9. PubMed ID: 30784784
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls.
    McKellop H; Shen FW; DiMaio W; Lancaster JG
    Clin Orthop Relat Res; 1999 Dec; (369):73-82. PubMed ID: 10611862
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Simulation of fretting wear at orthopaedic implant interfaces.
    Ebramzadeh E; Billi F; Sangiorgio SN; Mattes S; Schmoelz W; Dorr L
    J Biomech Eng; 2005 Jun; 127(3):357-63. PubMed ID: 16060342
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Head replacement, head rotation, and surface damage effects on metal-on-metal total hip replacements: a hip simulator study.
    Hardaker C; Dowson D; Isaac GH
    Proc Inst Mech Eng H; 2006 Feb; 220(2):209-17. PubMed ID: 16669388
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The wear of metal-on-metal total hip prostheses measured in a hip simulator.
    Scholes SC; Green SM; Unsworth A
    Proc Inst Mech Eng H; 2001; 215(6):523-30. PubMed ID: 11848384
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study.
    Siskey R; Ciccarelli L; Lui MK; Kurtz SM
    Clin Orthop Relat Res; 2016 Nov; 474(11):2428-2440. PubMed ID: 27677290
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene.
    Sakoda H; Voice AM; McEwen HM; Isaac GH; Hardaker C; Wroblewski BM; Fisher J
    J Arthroplasty; 2001 Dec; 16(8):1018-23. PubMed ID: 11740757
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Diamond coated total hip replacements.
    Lappalainen R; Anttila A; Heinonen H
    Clin Orthop Relat Res; 1998 Jul; (352):118-27. PubMed ID: 9678039
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.