These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

99 related articles for article (PubMed ID: 2716701)

  • 1. Hybrid reconstruction algorithm for x-ray computed tomography.
    Waggener R; Lee M; Mickish D; Lange J; Feldmeier J
    Med Phys; 1989; 16(2):197-201. PubMed ID: 2716701
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reconstruction for fan beam with an angular-dependent displaced center-of-rotation.
    Crawford CR; Gullberg GT; Tsui BM
    Med Phys; 1988; 15(1):67-71. PubMed ID: 3258402
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimal noise control in and fast reconstruction of fan-beam computed tomography image.
    Pan X
    Med Phys; 1999 May; 26(5):689-97. PubMed ID: 10360528
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reconstruction Algorithm for Fan Beam with a Displaced Center-of-Rotation.
    Gullberg GT; Crawford CR; Tsui BM
    IEEE Trans Med Imaging; 1986; 5(1):23-9. PubMed ID: 18243979
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accurate technique for complete geometric calibration of cone-beam computed tomography systems.
    Cho Y; Moseley DJ; Siewerdsen JH; Jaffray DA
    Med Phys; 2005 Apr; 32(4):968-83. PubMed ID: 15895580
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Exact fan-beam and 4pi-acquisition cone-beam SPECT algorithms with uniform attenuation correction.
    Tang Q; Zeng GL; Wu J; Gullberg GT
    Med Phys; 2005 Nov; 32(11):3440-7. PubMed ID: 16372416
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of ray profile modeling on resolution recovery in clinical CT.
    Hofmann C; Knaup M; Kachelrieß M
    Med Phys; 2014 Feb; 41(2):021907. PubMed ID: 24506628
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Direct two-dimensional reconstruction algorithm for an inverse-geometry CT system.
    Baek J; Pelc NJ
    Med Phys; 2009 Feb; 36(2):394-401. PubMed ID: 19291978
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of a non-linear weighted hybrid cone-beam CT reconstruction for circular trajectories.
    Gomi T; Koshida K; Miyati T
    Comput Med Imaging Graph; 2007 Oct; 31(7):561-9. PubMed ID: 17689223
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new method to retrieve phase information for equiangular fan beam differential phase contrast computed tomography.
    Wu Z; Gao K; Wang Z; Ge X; Chen J; Wang D; Pan Z; Zhang K; Zhu P; Wu Z
    Med Phys; 2013 Mar; 40(3):031911. PubMed ID: 23464326
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Generalized Fourier slice theorem for cone-beam image reconstruction.
    Zhao SR; Jiang D; Yang K; Yang K
    J Xray Sci Technol; 2015; 23(2):157-88. PubMed ID: 25882729
    [TBL] [Abstract][Full Text] [Related]  

  • 12. General surface reconstruction for cone-beam multislice spiral computed tomography.
    Chen L; Liang Y; Heuscher DJ
    Med Phys; 2003 Oct; 30(10):2804-21. PubMed ID: 14596317
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new iterative reconstruction algorithm for 2D exterior fan-beam CT.
    Zeng L; Liu B; Liu L; Xiang C
    J Xray Sci Technol; 2010; 18(3):267-77. PubMed ID: 20714085
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Combining scatter reduction and correction to improve image quality in cone-beam computed tomography (CBCT).
    Jin JY; Ren L; Liu Q; Kim J; Wen N; Guan H; Movsas B; Chetty IJ
    Med Phys; 2010 Nov; 37(11):5634-44. PubMed ID: 21158275
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit: preliminary phantom study.
    Ning R; Tang X; Conover D; Yu R
    Med Phys; 2003 Jul; 30(7):1694-705. PubMed ID: 12906186
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fast reconstruction with uniform noise properties in halfscan computed tomography.
    Pan X
    Med Phys; 2000 Sep; 27(9):2031-6. PubMed ID: 11011730
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analytic reconstruction approach for parallel translational computed tomography.
    Kong H; Yu H
    J Xray Sci Technol; 2015; 23(2):213-28. PubMed ID: 25882732
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A SPECT reconstruction method for extending parallel to non-parallel geometries.
    Wen J; Liang Z
    Phys Med Biol; 2010 Mar; 55(6):1631-41. PubMed ID: 20182002
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel extension of the parallel-beam projection-slice theorem to divergent fan-beam and cone-beam projections.
    Chen GH; Leng S; Mistretta CA
    Med Phys; 2005 Mar; 32(3):654-65. PubMed ID: 15839337
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Projection domain compensation of missing angles for fan-beam CT reconstruction.
    Lo SC; Lou SL; Mun SK
    Comput Med Imaging Graph; 1992; 16(4):259-69. PubMed ID: 1511399
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.