These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

320 related articles for article (PubMed ID: 27167025)

  • 1. Endovascular exclusion of a false lumen associated with residual dissection after proximal aortic repair using a custom-made false lumen occluder.
    Saitoh Y; Yokoi Y; Soeda T; Yuri K
    J Thorac Cardiovasc Surg; 2016 Aug; 152(2):e41-3. PubMed ID: 27167025
    [No Abstract]   [Full Text] [Related]  

  • 2. Endovascular rescue of an elephant trunk initially positioned in the false lumen of an aortic dissection.
    Crunelle B; Martin-Gonzalez T; Vincentelli A; Haulon S
    J Vasc Surg; 2016 Jul; 64(1):235. PubMed ID: 27345509
    [No Abstract]   [Full Text] [Related]  

  • 3. Volume analysis of true and false lumens in acute complicated type B aortic dissections after thoracic endovascular aortic repair with stent grafts alone or with a composite device design.
    Sobocinski J; Lombardi JV; Dias NV; Berger L; Zhou Q; Jia F; Resch T; Haulon S
    J Vasc Surg; 2016 May; 63(5):1216-24. PubMed ID: 26806523
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Candy-Plug Technique Using an Excluder Aortic Extender for Distal Occlusion of a Large False Lumen Aneurysm in Chronic Aortic Dissection.
    Ogawa Y; Nishimaki H; Chiba K; Murakami K; Sakurai Y; Fujiwara K; Miyairi T; Nakajima Y
    J Endovasc Ther; 2016 Jun; 23(3):483-6. PubMed ID: 27009975
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Treatment of Type I Endoleak after Thoracic Endovascular Aortic Repair and Stent Extension via False Lumen Catheterization and Coil Embolization.
    Liu Y; Huang S; Liu Y; He C
    Ann Vasc Surg; 2018 Nov; 53():268.e13-268.e16. PubMed ID: 30092426
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Coil Embolization for Persistent Thoracic False Lumen of Type B Aortic Dissection after Thoracic Endovascular Aortic Repair.
    Zhang H; Ge YY; Lu K; Cao L; Liu P; Liu XP; Wang LJ; Guo W
    Ann Vasc Surg; 2019 May; 57():60-68. PubMed ID: 30684608
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Endovascular Retrograde Reconstruction of the Left Renal Artery through the False Lumen of a Postdissection Thoracoabdominal Aortic Aneurysm-A Case Report.
    Jia S; Zhang H; Sun G; Ge Y; Wang L; Guo W
    Ann Vasc Surg; 2019 Feb; 55():307.e5-307.e11. PubMed ID: 30217715
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Successful endoluminal rescue of an endovascular graft unintentionally deployed in the false lumen of Stanford type B aortic dissection.
    Ma X; Fu W; Ma YT; Karmacharya U; Zhao J
    J Thorac Cardiovasc Surg; 2016 Mar; 151(3):e41-e45. PubMed ID: 26651956
    [No Abstract]   [Full Text] [Related]  

  • 9. Branched stent-grafts deployed in the true and false lumen to exclude a post dissecting thoracoabdominal aneurysm.
    Bertoglio L; Marone EM; Civilini E; Cambiaghi T; Mascia D; Chiesa R
    J Cardiovasc Surg (Torino); 2016 Oct; 57(5):646-52. PubMed ID: 26337013
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Repair of Chronic Aneurysmal Aortic Dissection Using a Stent Graft and an Amplatzer
    Kanaoka Y; Ohki T; Ozawa H
    Ann Vasc Surg; 2017 Feb; 39():288.e5-288.e12. PubMed ID: 27671450
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Original Off-Label Endovascular Solution to Occlude False Lumen Rupture in Chronic Type B Aortic Dissection.
    Marone EM; Leopardi M; Bertoglio L; Mascia D; Chiesa R
    Ann Vasc Surg; 2017 Apr; 40():299.e1-299.e5. PubMed ID: 27908812
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fenestrated Endovascular Aneurysm Repair of a Stent Graft-induced New Entry Tear in a Patient with a Celiacomesenteric Trunk.
    Fiorucci B; Tsilimparis N
    Eur J Vasc Endovasc Surg; 2017 Feb; 53(2):184. PubMed ID: 27890523
    [No Abstract]   [Full Text] [Related]  

  • 13. Use of the Octopus Endograft Technique to Reconstruct Renovisceral Arteries Arising From the False Lumen of a Rapidly Expanding Type B Aortic Dissection After Endovascular Repair.
    Xiong J; Ge Y; Liu X; Wang L; Guo W
    J Endovasc Ther; 2017 Feb; 24(1):107-111. PubMed ID: 27864460
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fenestrated and branched endovascular aortic repair for chronic type B aortic dissection with thoracoabdominal aneurysms.
    Kitagawa A; Greenberg RK; Eagleton MJ; Mastracci TM; Roselli EE
    J Vasc Surg; 2013 Sep; 58(3):625-34. PubMed ID: 23800455
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prospective multicenter clinical trial (STABLE) on the endovascular treatment of complicated type B aortic dissection using a composite device design.
    Lombardi JV; Cambria RP; Nienaber CA; Chiesa R; Teebken O; Lee A; Mossop P; Bharadwaj P;
    J Vasc Surg; 2012 Mar; 55(3):629-640.e2. PubMed ID: 22169668
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Retrograde type A dissection after thoracic endovascular repair due to the barb.
    Tanaka K; Saito M; Ohata T
    Asian Cardiovasc Thorac Ann; 2016 May; 24(4):364-6. PubMed ID: 25406404
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Thoracic Endovascular Aortic Repair into the False Lumen in Chronic Aortic Dissection.
    Kamman AV; Williams DM; Patel HJ
    Ann Vasc Surg; 2017 Jul; 42():303.e11-303.e14. PubMed ID: 28390917
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Endovascular aortic repair of a chronic ascending and arch aortic aneurysm.
    Gandet T; Alric P; Bommart S; Canaud L
    J Thorac Cardiovasc Surg; 2018 Mar; 155(3):e79-e83. PubMed ID: 28987735
    [No Abstract]   [Full Text] [Related]  

  • 19. Promoting False-Lumen Thrombosis after Thoracic Endovascular Aneurysm Repair in Type B Aortic Dissection by Selectively Excluding False-Lumen Distal Entry Tears.
    Wojtaszek M; Wnuk E; Maciag R; Lamparski K; Korzeniowski K; Rowinski O
    J Vasc Interv Radiol; 2017 Feb; 28(2):168-175. PubMed ID: 27645464
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Chronic type B dissections: are fenestrated and branched endografts an option?
    Sobocinski J; Hertault A; Tyrrell M; Maurel B; Azzaoui R; Haulon S
    J Cardiovasc Surg (Torino); 2013 Feb; 54(1 Suppl 1):97-107. PubMed ID: 23443594
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.