304 related articles for article (PubMed ID: 27177098)
1. Temperature field simulation and phantom validation of a Two-armed Spiral Antenna for microwave thermotherapy.
Du Y; Zhang L; Sang L; Wu D
Technol Health Care; 2016 Apr; 24 Suppl 2():S675-82. PubMed ID: 27177098
[TBL] [Abstract][Full Text] [Related]
2. [The temperature control for cancer thermotherapy using interstitial microwave antenna].
Xi X; Wang L; Wang W
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Dec; 23(6):1339-42. PubMed ID: 17228739
[TBL] [Abstract][Full Text] [Related]
3. Metamaterial based AMC backed archimedean spiral antenna for in-vitro microwave hyperthermia of skin cancer.
Kaur K; Kaur A
Electromagn Biol Med; 2023 Oct; 42(4):163-181. PubMed ID: 38156657
[TBL] [Abstract][Full Text] [Related]
4. [Design and implementation of an improved invasive antenna for microwave hyperthermia].
Xue Q; Sun B; Chen L; Wang J
Zhongguo Yi Liao Qi Xie Za Zhi; 2010 Nov; 34(6):427-30. PubMed ID: 21360981
[TBL] [Abstract][Full Text] [Related]
5. Design and characterisation of miniaturised cavity-backed patch antenna for microwave hyperthermia.
Chakaravarthi G; Arunachalam K
Int J Hyperthermia; 2015; 31(7):737-48. PubMed ID: 26365603
[TBL] [Abstract][Full Text] [Related]
6. Calculations of heating patterns of an array of microwave interstitial antennas.
Cherry PC; Iskander MF
IEEE Trans Biomed Eng; 1993 Aug; 40(8):771-9. PubMed ID: 8258443
[TBL] [Abstract][Full Text] [Related]
7. Temperature simulation of microwave ablation based on improved specific absorption rate method compared to phantom measurements.
Gao H; Wu S; Wang X; Hu R; Zhou Z; Sun X
Comput Assist Surg (Abingdon); 2017 Dec; 22(sup1):9-17. PubMed ID: 28922946
[TBL] [Abstract][Full Text] [Related]
8. Theoretical and experimental analysis of air cooling for intracavitary microwave hyperthermia applicators.
Yeh MM; Trembly BS; Douple EB; Ryan TP; Hoopes PJ; Jonsson E; Heaney JA
IEEE Trans Biomed Eng; 1994 Sep; 41(9):874-82. PubMed ID: 7959814
[TBL] [Abstract][Full Text] [Related]
9. Quantification of the 3-D electromagnetic power absorption rate in tissue during transurethral prostatic microwave thermotherapy using heat transfer model.
Zhu L; Xu LX; Chencinski N
IEEE Trans Biomed Eng; 1998 Sep; 45(9):1163-72. PubMed ID: 9735566
[TBL] [Abstract][Full Text] [Related]
10. The distribution of power and heat produced by interstitial microwave antenna arrays: I. Comparative phantom and canine studies.
Denman DL; Elson HR; Lewis GC; Breneman JC; Clausen CL; Dine J; Aron BS
Int J Radiat Oncol Biol Phys; 1988 Jan; 14(1):127-37. PubMed ID: 3335448
[TBL] [Abstract][Full Text] [Related]
11. Vesicoureteral reflux in children: a phantom study of microwave heating and radiometric thermometry of pediatric bladder.
Birkelund Y; Klemetsen Ø; Jacobsen SK; Arunachalam K; Maccarini P; Stauffer PR
IEEE Trans Biomed Eng; 2011 Nov; 58(11):3269-78. PubMed ID: 21900069
[TBL] [Abstract][Full Text] [Related]
12. In Silico Study on Tumor-Size-Dependent Thermal Profiles inside an Anthropomorphic Female Breast Phantom Subjected to Multi-Dipole Antenna Array.
Gas P; Miaskowski A; Subramanian M
Int J Mol Sci; 2020 Nov; 21(22):. PubMed ID: 33202658
[TBL] [Abstract][Full Text] [Related]
13. Performance characteristics of a helical microwave interstitial antenna for local hyperthermia.
Wu A; Watson ML; Sternick ES; Bielawa RJ; Carr KL
Med Phys; 1987; 14(2):235-7. PubMed ID: 3587145
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of a dual-arm Archimedean spiral array for microwave hyperthermia.
Johnson JE; Neuman DG; Maccarini PF; Juang T; Stauffer PR; Turner P
Int J Hyperthermia; 2006 Sep; 22(6):475-90. PubMed ID: 16971368
[TBL] [Abstract][Full Text] [Related]
15. Numerical study on thermal field of microwave ablation with water-cooled antenna.
Lu Y; Nan Q; Li L; Liu Y
Int J Hyperthermia; 2009 Mar; 25(2):108-15. PubMed ID: 19337911
[TBL] [Abstract][Full Text] [Related]
16. Design and optimization of an ultra wideband and compact microwave antenna for radiometric monitoring of brain temperature.
Rodrigues DB; Maccarini PF; Salahi S; Oliveira TR; Pereira PJ; Limao-Vieira P; Snow BW; Reudink D; Stauffer PR
IEEE Trans Biomed Eng; 2014 Jul; 61(7):2154-60. PubMed ID: 24759979
[TBL] [Abstract][Full Text] [Related]
17. Preliminary investigation of numerical estimation of coagulated region generated by interstitial microwave antenna.
Saito K; Ito K
Int J Hyperthermia; 2017 Feb; 33(1):69-73. PubMed ID: 27498719
[TBL] [Abstract][Full Text] [Related]
18. Tumour shape-dependent microwave hyperthermia using a novel coaxial micro-cut slot antenna.
Shamekhi L; Sayehvand HO; Karami H
J Therm Biol; 2020 Feb; 88():102473. PubMed ID: 32126004
[TBL] [Abstract][Full Text] [Related]
19. A clinical water-coated antenna applicator for MR-controlled deep-body hyperthermia: a comparison of calculated and measured 3-D temperature data sets.
Nadobny J; Wlodarczyk W; Westhoff L; Gellermann J; Felix R; Wust P
IEEE Trans Biomed Eng; 2005 Mar; 52(3):505-19. PubMed ID: 15759581
[TBL] [Abstract][Full Text] [Related]
20. Cardiac tissue ablation with catheter-based microwave heating.
Rappaport C
Int J Hyperthermia; 2004 Nov; 20(7):769-80. PubMed ID: 15675671
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]