625 related articles for article (PubMed ID: 27179204)
1. Occurrence and sources of brominated and organophosphorus flame retardants in dust from different indoor environments in Barcelona, Spain.
Cristale J; Hurtado A; Gómez-Canela C; Lacorte S
Environ Res; 2016 Aug; 149():66-76. PubMed ID: 27179204
[TBL] [Abstract][Full Text] [Related]
2. Occurrence and human exposure to brominated and organophosphorus flame retardants via indoor dust in a Brazilian city.
Cristale J; Aragão Belé TG; Lacorte S; Rodrigues de Marchi MR
Environ Pollut; 2018 Jun; 237():695-703. PubMed ID: 29129432
[TBL] [Abstract][Full Text] [Related]
3. Occurrence of alternative flame retardants in indoor dust from New Zealand: indoor sources and human exposure assessment.
Ali N; Dirtu AC; Van den Eede N; Goosey E; Harrad S; Neels H; 't Mannetje A; Coakley J; Douwes J; Covaci A
Chemosphere; 2012 Sep; 88(11):1276-82. PubMed ID: 22551874
[TBL] [Abstract][Full Text] [Related]
4. Halogenated flame-retardant concentrations in settled dust, respirable and inhalable particulates and polyurethane foam at gymnastic training facilities and residences.
La Guardia MJ; Hale RC
Environ Int; 2015 Jun; 79():106-14. PubMed ID: 25812808
[TBL] [Abstract][Full Text] [Related]
5. Brominated and organophosphorus flame retardants in South African indoor dust and cat hair.
Brits M; Brandsma SH; Rohwer ER; De Vos J; Weiss JM; de Boer J
Environ Pollut; 2019 Oct; 253():120-129. PubMed ID: 31302398
[TBL] [Abstract][Full Text] [Related]
6. Levels of polybrominated diphenyl ethers and novel flame retardants in microenvironment dust from Egypt: an assessment of human exposure.
Hassan Y; Shoeib T
Sci Total Environ; 2015 Feb; 505():47-55. PubMed ID: 25306095
[TBL] [Abstract][Full Text] [Related]
7. Measurement of legacy and emerging flame retardants in indoor dust from a rural village (Kopawa) in Nepal: Implication for source apportionment and health risk assessment.
Yadav IC; Devi NL; Singh VK; Li J; Zhang G
Ecotoxicol Environ Saf; 2019 Jan; 168():304-314. PubMed ID: 30390529
[TBL] [Abstract][Full Text] [Related]
8. Organophosphate compounds, polybrominated diphenyl ethers and novel brominated flame retardants in European indoor house dust: Use, evidence for replacements and assessment of human exposure.
de la Torre A; Navarro I; Sanz P; de Los Ángeles Martínez M
J Hazard Mater; 2020 Jan; 382():121009. PubMed ID: 31454611
[TBL] [Abstract][Full Text] [Related]
9. Novel brominated flame retardants - A review of their occurrence in indoor air, dust, consumer goods and food.
Zuiderveen EAR; Slootweg JC; de Boer J
Chemosphere; 2020 Sep; 255():126816. PubMed ID: 32417508
[TBL] [Abstract][Full Text] [Related]
10. Flame retardant associations between children's handwipes and house dust.
Stapleton HM; Misenheimer J; Hoffman K; Webster TF
Chemosphere; 2014 Dec; 116():54-60. PubMed ID: 24485814
[TBL] [Abstract][Full Text] [Related]
11. Emerging and legacy flame retardants in indoor dust from East China.
Peng C; Tan H; Guo Y; Wu Y; Chen D
Chemosphere; 2017 Nov; 186():635-643. PubMed ID: 28818590
[TBL] [Abstract][Full Text] [Related]
12. Concentrations of legacy and novel brominated flame retardants in indoor dust in Melbourne, Australia: An assessment of human exposure.
McGrath TJ; Morrison PD; Ball AS; Clarke BO
Environ Int; 2018 Apr; 113():191-201. PubMed ID: 29428609
[TBL] [Abstract][Full Text] [Related]
13. "Novel" brominated flame retardants in Belgian and UK indoor dust: implications for human exposure.
Ali N; Harrad S; Goosey E; Neels H; Covaci A
Chemosphere; 2011 May; 83(10):1360-5. PubMed ID: 21458020
[TBL] [Abstract][Full Text] [Related]
14. Legacy and novel brominated flame retardants in interior car dust - Implications for human exposure.
Besis A; Christia C; Poma G; Covaci A; Samara C
Environ Pollut; 2017 Nov; 230():871-881. PubMed ID: 28735244
[TBL] [Abstract][Full Text] [Related]
15. Concentrations of brominated and phosphorous flame retardants in Finnish house dust and insights into children's exposure.
Rantakokko P; Kumar E; Braber J; Huang T; Kiviranta H; Cequier E; Thomsen C
Chemosphere; 2019 May; 223():99-107. PubMed ID: 30771653
[TBL] [Abstract][Full Text] [Related]
16. Contamination status, emission sources, and human health risk of brominated flame retardants in urban indoor dust from Hanoi, Vietnam: the replacement of legacy polybrominated diphenyl ether mixtures by alternative formulations.
Hoang MTT; Anh HQ; Kadokami K; Duong HT; Hoang HM; Van Nguyen T; Takahashi S; Le GT; Trinh HT
Environ Sci Pollut Res Int; 2021 Aug; 28(32):43885-43896. PubMed ID: 33837942
[TBL] [Abstract][Full Text] [Related]
17. Exposure to brominated and organophosphate ester flame retardants in U.S. childcare environments: Effect of removal of flame-retarded nap mats on indoor levels.
Stubbings WA; Schreder ED; Thomas MB; Romanak K; Venier M; Salamova A
Environ Pollut; 2018 Jul; 238():1056-1068. PubMed ID: 29703676
[TBL] [Abstract][Full Text] [Related]
18. Levels of non-polybrominated diphenyl ether brominated flame retardants in residential house dust samples and fire station dust samples in California.
Brown FR; Whitehead TP; Park JS; Metayer C; Petreas MX
Environ Res; 2014 Nov; 135():9-14. PubMed ID: 25261858
[TBL] [Abstract][Full Text] [Related]
19. Occurrence of flame retardants in landfills: A case study in Brazil.
Cristale J; Aragão Belé TG; Lacorte S; de Marchi MRR
Environ Res; 2019 Jan; 168():420-427. PubMed ID: 30388499
[TBL] [Abstract][Full Text] [Related]
20. Exposure assessment of organophosphorus and organobromine flame retardants via indoor dust from elementary schools and domestic houses.
Mizouchi S; Ichiba M; Takigami H; Kajiwara N; Takamuku T; Miyajima T; Kodama H; Someya T; Ueno D
Chemosphere; 2015 Mar; 123():17-25. PubMed ID: 25532762
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]