These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 27181489)

  • 1. Plain Radiographs are a Useful Substitute for Computed Tomography in Evaluating Acetabular Cup Version.
    Noback PC; Danoff JR; Herschmiller T; Bobman JT; Shah RP; Geller JA; Macaulay W
    J Arthroplasty; 2016 Oct; 31(10):2320-4. PubMed ID: 27181489
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of Acetabular Component Anteversion after Total Hip Arthroplasty: Comparison of Anteroposterior and Cross-Table Lateral Radiographs with Computed Tomography Scans.
    Goyal T; Paul S; Choudhury AK; Gupta T
    Clin Orthop Surg; 2021 Sep; 13(3):329-335. PubMed ID: 34484625
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of plain antero-posterior radiographic-based methods for measurement of acetabular cup version.
    Alzohiry MA; Abdelnasser MK; Moustafa M; Mahran M; Bakr H; Khalifa Y; Abelaal A; Atta H; Said GZ
    Int Orthop; 2018 Dec; 42(12):2777-2785. PubMed ID: 29869012
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The validity and reproducibility of cross table radiographs compared with CT scans for the measurement of anteversion of the acetabular component after total hip arthroplasty.
    Pankaj A; Mittal A; Chawla A
    Bone Joint J; 2017 Aug; 99-B(8):1006-1011. PubMed ID: 28768776
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reduced-dose computed tomography is the most accurate method to measure ceramic hip resurfacing cup version.
    Saracco A; Grassi A; Romagnoli M; Camarda L; Logishetty K; Zaffagnini S; Cobb J
    Eur J Radiol; 2020 Jul; 128():109040. PubMed ID: 32442835
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy and precision of version angle measurements of the acetabular component after total hip arthroplasty.
    Nishino H; Nakamura S; Arai N; Matsushita T
    J Arthroplasty; 2013 Oct; 28(9):1644-7. PubMed ID: 23566697
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reliability and validity of measuring acetabular component orientation by plain anteroposterior radiographs.
    Lu M; Zhou YX; Du H; Zhang J; Liu J
    Clin Orthop Relat Res; 2013 Sep; 471(9):2987-94. PubMed ID: 23645336
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Definition of a quantitative measurement method for acetabular version in a plain radiograph in the healthy adult hip.
    Özçelik A; Akalın Y; Çalışır C; İnan U; Ömeroğlu H
    Eklem Hastalik Cerrahisi; 2015; 26(1):2-5. PubMed ID: 25741912
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of planar anteversion measurements using anteroposterior radiographs.
    Lee GC; Lee SH; Kang SW; Park HS; Jo S
    BMC Musculoskelet Disord; 2019 Dec; 20(1):586. PubMed ID: 31805912
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Three Patterns of Acetabular Deficiency Are Common in Young Adult Patients With Acetabular Dysplasia.
    Nepple JJ; Wells J; Ross JR; Bedi A; Schoenecker PL; Clohisy JC
    Clin Orthop Relat Res; 2017 Apr; 475(4):1037-1044. PubMed ID: 27830486
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Functional acetabular orientation varies between supine and standing radiographs: implications for treatment of femoroacetabular impingement.
    Ross JR; Tannenbaum EP; Nepple JJ; Kelly BT; Larson CM; Bedi A
    Clin Orthop Relat Res; 2015 Apr; 473(4):1267-73. PubMed ID: 25560956
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reliability and Validity of Standing Lateral Radiograph Method for Measuring Acetabular Component Version: A Modified Cross-table Lateral Radiograph Method.
    Zhang W; Xu J; Li D; Sun H; Cai Z; Chen M; Ma R
    Orthop Surg; 2022 Aug; 14(8):1622-1629. PubMed ID: 35711111
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Computer tomography in the diagnosis and therapy of acetabular fractures].
    Senohradski K; Karovic B; Miric D
    Srp Arh Celok Lek; 2001; 129(7-8):194-8. PubMed ID: 11797449
    [TBL] [Abstract][Full Text] [Related]  

  • 14. How Reliable is the Acetabular Cup Position Assessment from Routine Radiographs?
    Carvajal Alba JA; Vincent HK; Sodhi JS; Latta LL; Parvataneni HK
    Iowa Orthop J; 2017; 37():181-187. PubMed ID: 28852355
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurements of acetabular cup position and pelvic spatial orientation after total hip arthroplasty using computed tomography/radiography matching.
    Blendea S; Eckman K; Jaramaz B; Levison TJ; Digioia AM
    Comput Aided Surg; 2005 Jan; 10(1):37-43. PubMed ID: 16199380
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Not All Hip Dysplasias are the Same: Preoperative CT Version Study and the Need for Reverse Bernese Periacetabular Osteotomy.
    Thawrani DP; Feldman DS; Sala DA
    J Pediatr Orthop; 2017 Jan; 37(1):47-52. PubMed ID: 26196495
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measuring acetabular component version after THA: CT or plain radiograph?
    McArthur B; Cross M; Geatrakas C; Mayman D; Ghelman B
    Clin Orthop Relat Res; 2012 Oct; 470(10):2810-8. PubMed ID: 22395871
    [TBL] [Abstract][Full Text] [Related]  

  • 18. CT outperforms radiography for determination of acetabular cup version after THA.
    Ghelman B; Kepler CK; Lyman S; Della Valle AG
    Clin Orthop Relat Res; 2009 Sep; 467(9):2362-70. PubMed ID: 19277802
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The reliability of measuring acetabular component position on radiographs using everyday diagnostic imaging software.
    Lahy J; Stevens J; McKenzie D; de Steiger R
    J Orthop Surg (Hong Kong); 2017; 25(2):2309499017718953. PubMed ID: 28675977
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Functional acetabular component position with supine total hip replacement.
    Eilander W; Harris SJ; Henkus HE; Cobb JP; Hogervorst T
    Bone Joint J; 2013 Oct; 95-B(10):1326-31. PubMed ID: 24078527
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.