These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

73 related articles for article (PubMed ID: 2718313)

  • 1. [Theoretical bases of convex tonometry and potentialities of its use].
    Krasnov MM; Basov GV
    Vestn Oftalmol; 1989; 105(1):49-51. PubMed ID: 2718313
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [New principle of measuring intraocular pressure (convex tonometry and convex tonography)].
    Krasnov MM
    Vestn Oftalmol; 1981; (1):53-4. PubMed ID: 7222354
    [No Abstract]   [Full Text] [Related]  

  • 3. [Theoretical basis of goldmann applanation tonometry].
    Wiegand W; Schroeder B; Hager A
    Klin Monbl Augenheilkd; 2005 Jul; 222(7):552-7. PubMed ID: 16034722
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Intraocular pressure difference in Goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01"PRA" in glaucoma patients].
    Schlote T; Landenberger H
    Klin Monbl Augenheilkd; 2005 Feb; 222(2):123-31. PubMed ID: 15719316
    [TBL] [Abstract][Full Text] [Related]  

  • 5. New ways to measure intraocular pressure.
    ElMallah MK; Asrani SG
    Curr Opin Ophthalmol; 2008 Mar; 19(2):122-6. PubMed ID: 18301285
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The pressure phosphene tonometer--a clinical evaluation.
    Chew GS; Sanderson GF; Molteno AC
    Eye (Lond); 2005 Jun; 19(6):683-5. PubMed ID: 15192693
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measuring intraocular pressure-adjustments for corneal thickness and new technologies.
    Herndon LW
    Curr Opin Ophthalmol; 2006 Apr; 17(2):115-9. PubMed ID: 16552245
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of invasive and non-invasive tonometry in the mouse.
    Morris CA; Crowston JG; Lindsey JD; Danias J; Weinreb RN
    Exp Eye Res; 2006 Jun; 82(6):1094-9. PubMed ID: 16466714
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Estimation of intraocular pressure in rabbits using noncontact tonometer: a comparative evaluation with Schiotz tonometer.
    Gupta SK; Saxena R; Agarwal R; Galpalli ND; Srivastava S; Agrawal SS
    Methods Find Exp Clin Pharmacol; 2007; 29(6):405-9. PubMed ID: 17922069
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes.
    García-Resúa C; González-Meijome JM; Gilino J; Yebra-Pimentel E
    Optom Vis Sci; 2006 Feb; 83(2):102-7. PubMed ID: 16501412
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The evaluation of tonometry and self-tonometry with Ocuton tonometers.
    Kóthy P; Nagymihály A; Holló G
    Med Sci Monit; 2003 Jan; 9(1):PI1-4. PubMed ID: 12552251
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Theoretical significance of the results of convex tonography].
    Krasnov MM; Basov GV
    Vestn Oftalmol; 1983; (3):13-6. PubMed ID: 6879904
    [No Abstract]   [Full Text] [Related]  

  • 13. [Self-measurement of intraocular pressure].
    Theisen R; Scherer V; Ruprecht KW
    J Fr Ophtalmol; 2001 Apr; 24(4):378-81. PubMed ID: 11351210
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Intraocular pressure measurements with the Proview self-tonometer in comparison of Goldmann applanation tonometry in healthy and glaucomatous eyes].
    Meyer MW; Yevelenko V; Hoy L; Meyer A; Erb C
    Klin Monbl Augenheilkd; 2006 Nov; 223(11):899-903. PubMed ID: 17131250
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reliability of the Nidek NT-1000 non contact tonometer.
    Van de Velde T; Zeyen T
    Bull Soc Belge Ophtalmol; 1995; 255():19-22. PubMed ID: 7496571
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dynamic contour tonometry for intraocular pressure measurement.
    Kamppeter BA; Jonas JB
    Am J Ophthalmol; 2005 Aug; 140(2):318-20. PubMed ID: 16086958
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of intraocular pressure at the end of cataract surgery.
    Antao SF; Kasaby H
    J Cataract Refract Surg; 2008 Feb; 34(2):258-61. PubMed ID: 18242450
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Once more about the diagnostic capacities of elastic tonometry].
    Avetisov SE; Bubnova IA; Antonov AA
    Vestn Oftalmol; 2008; 124(5):19-21. PubMed ID: 19062552
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intraocular pressure measurement in mice: a comparison between Goldmann and rebound tonometry.
    Kim CY; Kuehn MH; Anderson MG; Kwon YH
    Eye (Lond); 2007 Sep; 21(9):1202-9. PubMed ID: 16946746
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [ProTon--a new portable tonometer. Initial experimental and clinical results].
    Sachs H; Lohmann CP; Scherbauer M; Gabel VP
    Ophthalmologe; 1995 Aug; 92(4):574-6. PubMed ID: 7549350
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.