BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

465 related articles for article (PubMed ID: 27189156)

  • 1. Cryoballoon ablation for pulmonary vein isolation in patients with atrial fibrillation: preliminary results using novel short-tip cryoballoon.
    Koektuerk B; Yorgun H; Koektuerk O; Turan CH; Aksoy MN; Turan RG; Gorr E; Bansmann PM; Hoppe C; Horlitz M
    J Interv Card Electrophysiol; 2016 Oct; 47(1):91-98. PubMed ID: 27189156
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improved visualisation of real-time recordings during third generation cryoballoon ablation: a comparison between the novel short-tip and the second generation device.
    Mugnai G; de Asmundis C; Hünük B; Ströker E; Moran D; Hacioglu E; Ruggiero D; Poelaert J; Verborgh C; Umbrain V; Beckers S; Coutino-Moreno HE; Takarada K; de Regibus V; Brugada P; Chierchia GB
    J Interv Card Electrophysiol; 2016 Sep; 46(3):307-14. PubMed ID: 26873259
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Predictors of durable electrical isolation in the setting of second-generation cryoballoon ablation: A comparison between left superior, left inferior, right superior, and right inferior pulmonary veins.
    Scala O; Borio G; Paparella G; Varnavas V; Ströker E; Guimaraes Osorio T; Terasawa M; Sieira J; Maj R; Rizzo A; Al-Hosari MM; Galli A; Brugada P; de Asmundis C; Chierchia GB
    J Cardiovasc Electrophysiol; 2020 Jan; 31(1):128-136. PubMed ID: 31749209
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Electrophysiological findings following pulmonary vein isolation using radiofrequency catheter guided by contact-force and second-generation cryoballoon: lessons from repeat ablation procedures.
    Ciconte G; Velagić V; Mugnai G; Saitoh Y; Irfan G; Hunuk B; Ströker E; Conte G; Sieira J; Di Giovanni G; Baltogiannis G; Brugada P; de Asmundis C; Chierchia GB
    Europace; 2016 Jan; 18(1):71-7. PubMed ID: 26445821
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High rate of durable pulmonary vein isolation after second-generation cryoballoon ablation: analysis of repeat procedures.
    Bordignon S; Fürnkranz A; Perrotta L; Dugo D; Konstantinou A; Nowak B; Schulte-Hahn B; Schmidt B; Chun KR
    Europace; 2015 May; 17(5):725-31. PubMed ID: 25618741
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Additional cryoapplications at the pulmonary vein antrum using a 28-mm second-generation cryoballoon: a pilot study of extra-pulmonary vein ablation.
    Miyazaki S; Kajiyama T; Watanabe T; Ichijo S; Iesaka Y
    Heart Vessels; 2018 Sep; 33(9):1052-1059. PubMed ID: 29464341
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Catheter ablation using the third-generation cryoballoon provides an enhanced ability to assess time to pulmonary vein isolation facilitating the ablation strategy: Short- and long-term results of a multicenter study.
    Aryana A; Kowalski M; O'Neill PG; Koo CH; Lim HW; Khan A; Hokanson RB; Bowers MR; Kenigsberg DN; Ellenbogen KA;
    Heart Rhythm; 2016 Dec; 13(12):2306-2313. PubMed ID: 27503480
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pulmonary vein isolation during cryoballoon ablation using the novel Achieve inner lumen mapping catheter: a feasibility study.
    Chierchia GB; de Asmundis C; Namdar M; Westra S; Kuniss M; Sarkozy A; Bayrak F; Ricciardi D; Casado-Arroyo R; Rodriguez Manero M; Rao JY; Smeets J; Brugada P
    Europace; 2012 Jul; 14(7):962-7. PubMed ID: 22411731
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Predictors of durable pulmonary vein isolation after second-generation cryoballoon ablation with a single short freeze strategy - Different criteria for the best freeze of the 4 individual PVs.
    Miyazaki S; Kajiyama T; Watanabe T; Nakamura H; Hachiya H; Tada H; Iesaka Y
    Int J Cardiol; 2020 Feb; 301():96-102. PubMed ID: 31759685
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pulmonary vein re-mapping after cryoballoon ablation for atrial fibrillation.
    Yokoyama K; Tokuda M; Matsuo S; Isogai R; Tokutake K; Kato M; Narui R; Tanigawa S; Yamashita S; Inada K; Yoshimura M; Yamane T
    Europace; 2018 Jun; 20(6):943-948. PubMed ID: 29016768
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Short tip-big difference? First-in-man experience and procedural efficacy of pulmonary vein isolation using the third-generation cryoballoon.
    Heeger CH; Wissner E; Mathew S; Hayashi K; Sohns C; Reißmann B; Lemes C; Maurer T; Fink T; Saguner AM; Santoro F; Riedl J; Ouyang F; Kuck KH; Metzner A
    Clin Res Cardiol; 2016 Jun; 105(6):482-8. PubMed ID: 26608161
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation.
    Ghosh J; Martin A; Keech AC; Chan KH; Gomes S; Singarayar S; McGuire MA
    Heart Rhythm; 2013 Sep; 10(9):1311-7. PubMed ID: 23792110
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Phrenic nerve paralysis during cryoballoon ablation for atrial fibrillation: a comparison between the first- and second-generation balloon.
    Casado-Arroyo R; Chierchia GB; Conte G; Levinstein M; Sieira J; Rodriguez-Mañero M; di Giovanni G; Baltogiannis Y; Wauters K; de Asmundis C; Sarkozy A; Brugada P
    Heart Rhythm; 2013 Sep; 10(9):1318-24. PubMed ID: 23891574
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Characterization of Electrical Reconnection Following Pulmonary Vein Isolation Using First- and Second-Generation Cryoballoon.
    Koektuerk B; Yorgun H; Koektuerk O; Turan CH; Keskin K; Schoett M; Turan RG; Gorr E; Hoppe C; Horlitz M
    Pacing Clin Electrophysiol; 2016 May; 39(5):434-42. PubMed ID: 26910475
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Increased rate of observed real-time pulmonary vein isolation with third-generation short-tip cryoballoon.
    Pott A; Petscher K; Messemer M; Rottbauer W; Dahme T
    J Interv Card Electrophysiol; 2016 Dec; 47(3):333-339. PubMed ID: 27448816
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Procedural and biophysical indicators of durable pulmonary vein isolation during cryoballoon ablation of atrial fibrillation.
    Aryana A; Mugnai G; Singh SM; Pujara DK; de Asmundis C; Singh SK; Bowers MR; Brugada P; d'Avila A; O'Neill PG; Chierchia GB
    Heart Rhythm; 2016 Feb; 13(2):424-32. PubMed ID: 26520204
    [TBL] [Abstract][Full Text] [Related]  

  • 17. One-year clinical success of a 'no-bonus' freeze protocol using the second-generation 28 mm cryoballoon for pulmonary vein isolation.
    Wissner E; Heeger CH; Grahn H; Reissmann B; Wohlmuth P; Lemes C; Rausch P; Mathew S; Rillig A; Deiss S; Maurer T; Lin T; Tilz RR; Ouyang F; Kuck KH; Metzner A
    Europace; 2015 Aug; 17(8):1236-40. PubMed ID: 25868468
    [TBL] [Abstract][Full Text] [Related]  

  • 18. On the Quest for the Best Freeze: Predictors of Late Pulmonary Vein Reconnections After Second-Generation Cryoballoon Ablation.
    Ciconte G; Mugnai G; Sieira J; Velagić V; Saitoh Y; Irfan G; Hunuk B; Ströker E; Conte G; Di Giovanni G; Baltogiannis G; Wauters K; Brugada P; de Asmundis C; Chierchia GB
    Circ Arrhythm Electrophysiol; 2015 Dec; 8(6):1359-65. PubMed ID: 26527624
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Second-Generation Cryoballoon Ablation in the Setting of Lone Paroxysmal Atrial Fibrillation: Single Procedural Outcome at 12 Months.
    DE Regibus V; Mugnai G; Moran D; Hünük B; Ströker E; Hacioglu E; Ruggiero D; Coutiño-Moreno HE; Takarada K; Brugada P; DE Asmundis C; Chierchia GB
    J Cardiovasc Electrophysiol; 2016 Jun; 27(6):677-82. PubMed ID: 27026284
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spontaneous and adenosine-induced pulmonary vein reconnection after cryoballoon ablation with the second-generation device.
    Ciconte G; Chierchia GB; DE Asmundis C; Sieira J; Conte G; Juliá J; DI Giovanni G; Wauters K; Baltogiannis G; Saitoh Y; Mugnai G; Catanzariti D; Tondo C; Brugada P
    J Cardiovasc Electrophysiol; 2014 Aug; 25(8):845-851. PubMed ID: 24678900
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 24.