BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

465 related articles for article (PubMed ID: 27189156)

  • 21. Clinical recurrence and electrical pulmonary vein reconnections after second-generation cryoballoon ablation.
    Miyazaki S; Taniguchi H; Hachiya H; Nakamura H; Takagi T; Hirao K; Iesaka Y
    Heart Rhythm; 2016 Sep; 13(9):1852-7. PubMed ID: 27241352
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: a multicentre European evaluation.
    Squara F; Zhao A; Marijon E; Latcu DG; Providencia R; Di Giovanni G; Jauvert G; Jourda F; Chierchia GB; De Asmundis C; Ciconte G; Alonso C; Grimard C; Boveda S; Cauchemez B; Saoudi N; Brugada P; Albenque JP; Thomas O
    Europace; 2015 May; 17(5):718-24. PubMed ID: 25840289
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Validation of electrical ostial pulmonary vein isolation verified with a spiral inner lumen mapping catheter during second-generation cryoballoon ablation.
    Miyazaki S; Kajiyama T; Watanabe T; Taniguchi H; Nakamura H; Hamaya R; Kusa S; Igarashi M; Hachiya H; Hirao K; Iesaka Y
    J Cardiovasc Electrophysiol; 2017 Aug; 28(8):870-875. PubMed ID: 28497857
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Increased incidence of esophageal thermal lesions using the second-generation 28-mm cryoballoon.
    Metzner A; Burchard A; Wohlmuth P; Rausch P; Bardyszewski A; Gienapp C; Tilz RR; Rillig A; Mathew S; Deiss S; Makimoto H; Ouyang F; Kuck KH; Wissner E
    Circ Arrhythm Electrophysiol; 2013 Aug; 6(4):769-75. PubMed ID: 23748208
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Stand-alone mapping using different transluminal mapping catheters--an accurate and safe way to isolate all pulmonary veins with the cryoballoon?
    Schade A; Schumacher B; Dietrich JW; Langbein A; Groschup G; Koucky K; Krug J; Stahl C; Müller P; Nentwich K; Roos M; Deneke T
    J Interv Card Electrophysiol; 2015 Jan; 42(1):33-41. PubMed ID: 25504268
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Pulmonary vein reconnection following catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: results of a multicenter analysis.
    Aryana A; Singh SM; Mugnai G; de Asmundis C; Kowalski M; Pujara DK; Cohen AI; Singh SK; Fuenzalida CE; Prager N; Bowers MR; O'Neill PG; Brugada P; d'Avila A; Chierchia GB
    J Interv Card Electrophysiol; 2016 Dec; 47(3):341-348. PubMed ID: 27475949
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Single 3-min freeze per vein ablation strategy with the second-generation cryoballoon for atrial fibrillation in a large cohort of patients: long term outcome after a single procedure.
    Coutiño HE; Abugattas JP; Sieira J; Salghetti F; Ströker E; Paparella G; Haine E; Varnavas V; Umbrain V; Terasawa M; De Greef Y; Brugada P; Iacopino S; de Asmundis C; Chierchia GB
    J Interv Card Electrophysiol; 2018 Oct; 53(1):81-89. PubMed ID: 29948587
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Verification of pulmonary vein isolation during single transseptal cryoballoon ablation: a comparison between the classical circular mapping catheter and the inner lumen mapping catheter.
    Chierchia GB; Namdar M; Sarkozy A; Sorgente A; de Asmundis C; Casado-Arroyo R; Capulzini L; Bayrak F; Rodriguez-Mañero M; Ricciardi D; Rao JY; Overeinder I; Paparella G; Brugada P
    Europace; 2012 Dec; 14(12):1708-14. PubMed ID: 22772051
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Durability of Pulmonary Vein Isolation with Cryoballoon Ablation: Results from the Sustained PV Isolation with Arctic Front Advance (SUPIR) Study.
    Reddy VY; Sediva L; Petru J; Skoda J; Chovanec M; Chitovova Z; Di Stefano P; Rubin E; Dukkipati S; Neuzil P
    J Cardiovasc Electrophysiol; 2015 May; 26(5):493-500. PubMed ID: 25644659
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Pulmonary Vein Isolation Using the First-Generation Cryoballoon Technique in Chinese Patients.
    Zhou GB; Guo XG; Liu XU; Yang JD; Sun QI; Ma J; Zhang S
    Pacing Clin Electrophysiol; 2015 Sep; 38(9):1073-81. PubMed ID: 26096255
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Analysis of the heart rate variability during cryoballoon ablation of atrial fibrillation.
    Mori H; Kato R; Ikeda Y; Goto K; Tanaka S; Asano S; Shiki Y; Nagase T; Iwanaga S; Nishimura S; Muramatsu T; Matsumoto K
    Europace; 2018 Aug; 20(8):1259-1267. PubMed ID: 29016780
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Cryoballoon ablation during atrial fibrillation is associated with faster temperature drop and lower freezing temperatures.
    Mugnai G; Moran D; Ströker E; Ruggiero D; Coutino-Moreno HE; Takarada K; De Regibus V; Choudhury R; Iacopino S; Filannino P; Umbrain V; Beckers S; Brugada P; de Asmundis C; Chierchia GB
    J Interv Card Electrophysiol; 2016 Dec; 47(3):357-364. PubMed ID: 27525722
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Initial experience and procedural efficacy of pulmonary vein isolation using the fourth-generation cryoballoon - a step forward?
    Mathew S; Rottner L; Warneke L; Maurer T; Lemes C; Hashiguchi N; Reißmann B; Goldmann B; Ouyang F; Kuck KH; Metzner A; Rillig A
    Acta Cardiol; 2020 Dec; 75(8):754-759. PubMed ID: 31630633
    [No Abstract]   [Full Text] [Related]  

  • 34. Anatomical predictors for acute and mid-term success of cryoballoon ablation of atrial fibrillation using the 28 mm balloon.
    Knecht S; Kühne M; Altmann D; Ammann P; Schaer B; Osswald S; Sticherling C
    J Cardiovasc Electrophysiol; 2013 Feb; 24(2):132-8. PubMed ID: 23130991
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Pulmonary Vein Stenosis After Second-Generation Cryoballoon Ablation.
    Matsuda J; Miyazaki S; Nakamura H; Taniguchi H; Kajiyama T; Hachiya H; Takagi T; Iesaka Y; Hirao K; Isobe M
    J Cardiovasc Electrophysiol; 2017 Mar; 28(3):298-303. PubMed ID: 28032927
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Incidence of real-time recordings of pulmonary vein potentials using the third-generation short-tip cryoballoon.
    Chierchia GB; Mugnai G; Ströker E; Velagic V; Hünük B; Moran D; Hacioglu E; Poelaert J; Verborgh C; Umbrain V; Beckers S; Ruggiero D; Brugada P; de Asmundis C
    Europace; 2016 Aug; 18(8):1158-63. PubMed ID: 26857185
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Esophageal endoscopy results after pulmonary vein isolation using the single big cryoballoon technique.
    Fürnkranz A; Chun KR; Metzner A; Nuyens D; Schmidt B; Burchard A; Tilz R; Ouyang F; Kuck KH
    J Cardiovasc Electrophysiol; 2010 Aug; 21(8):869-74. PubMed ID: 20233270
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Quantitative Analysis of the Isolation Area During the Chronic Phase After a 28-mm Second-Generation Cryoballoon Ablation Demarcated by High-Resolution Electroanatomic Mapping.
    Miyazaki S; Taniguchi H; Hachiya H; Nakamura H; Takagi T; Iwasawa J; Hirao K; Iesaka Y
    Circ Arrhythm Electrophysiol; 2016 May; 9(5):e003879. PubMed ID: 27146418
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The fourth cryoballoon generation with a shorter tip to facilitate real-time pulmonary vein potential recording: Feasibility and safety results.
    Straube F; Dorwarth U; Pongratz J; Brück B; Wankerl M; Hartl S; Hoffmann E
    J Cardiovasc Electrophysiol; 2019 Jun; 30(6):918-925. PubMed ID: 30907462
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The incidence of phrenic nerve injury during pulmonary vein isolation using the second-generation 28 mm cryoballoon.
    Metzner A; Rausch P; Lemes C; Reissmann B; Bardyszewski A; Tilz R; Rillig A; Mathew S; Deiss S; Kamioka M; Toennis T; Lin T; Ouyang F; Kuck KH; Wissner E
    J Cardiovasc Electrophysiol; 2014 May; 25(5):466-470. PubMed ID: 24400647
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 24.