These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. An Operative Complexity Index Shows Higher Volume Hospitals and Surgeons Perform More Complex Adult Spine Deformity Operations. Paul JC; Lonner BS; Goz V; Karia R; Toombs CS; Errico TJ Bull Hosp Jt Dis (2013); 2016 Nov; 74(4):292-269. PubMed ID: 27815948 [TBL] [Abstract][Full Text] [Related]
3. Accuracy and safety of pedicle screw placement in neuromuscular scoliosis with free-hand technique. Modi HN; Suh SW; Fernandez H; Yang JH; Song HR Eur Spine J; 2008 Dec; 17(12):1686-96. PubMed ID: 18830636 [TBL] [Abstract][Full Text] [Related]
4. Accuracy of pedicle and mass screw placement in the spine without using fluoroscopy: a prospective clinical study. Kotil K; Bilge T Spine J; 2008; 8(4):591-6. PubMed ID: 17602885 [TBL] [Abstract][Full Text] [Related]
5. Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study. Devito DP; Kaplan L; Dietl R; Pfeiffer M; Horne D; Silberstein B; Hardenbrook M; Kiriyanthan G; Barzilay Y; Bruskin A; Sackerer D; Alexandrovsky V; Stüer C; Burger R; Maeurer J; Donald GD; Schoenmayr R; Friedlander A; Knoller N; Schmieder K; Pechlivanis I; Kim IS; Meyer B; Shoham M Spine (Phila Pa 1976); 2010 Nov; 35(24):2109-15. PubMed ID: 21079498 [TBL] [Abstract][Full Text] [Related]
6. Safety and accuracy of robot-assisted versus fluoroscopy-guided pedicle screw insertion for degenerative diseases of the lumbar spine: a matched cohort comparison. Schatlo B; Molliqaj G; Cuvinciuc V; Kotowski M; Schaller K; Tessitore E J Neurosurg Spine; 2014 Jun; 20(6):636-43. PubMed ID: 24725180 [TBL] [Abstract][Full Text] [Related]
7. Development of a new technique for pedicle screw and Magerl screw insertion using a 3-dimensional image guide. Kawaguchi Y; Nakano M; Yasuda T; Seki S; Hori T; Kimura T Spine (Phila Pa 1976); 2012 Nov; 37(23):1983-8. PubMed ID: 22531473 [TBL] [Abstract][Full Text] [Related]
8. Computer-assisted spinal navigation using a percutaneous dynamic reference frame for posterior fusions of the lumbar spine. Best NM; Sasso RC; Garrido BJ Am J Orthop (Belle Mead NJ); 2009 Aug; 38(8):387-91. PubMed ID: 19809603 [TBL] [Abstract][Full Text] [Related]
9. Pedicle screw augmentation with polyethylene tape: a biomechanical study in the osteoporotic thoracolumbar spine. Hamasaki T; Tanaka N; Kim J; Okada M; Ochi M; Hutton WC J Spinal Disord Tech; 2010 Apr; 23(2):127-32. PubMed ID: 20051920 [TBL] [Abstract][Full Text] [Related]
10. A retrospective analysis of pedicle screws in contact with the great vessels. Foxx KC; Kwak RC; Latzman JM; Samadani U J Neurosurg Spine; 2010 Sep; 13(3):403-6. PubMed ID: 20809738 [TBL] [Abstract][Full Text] [Related]
11. On Patient Safety: Is it Possible to Operate Too Much? Lee MJ Clin Orthop Relat Res; 2017 Dec; 475(12):2858-2860. PubMed ID: 28643078 [No Abstract] [Full Text] [Related]
13. The da Vinci robotic surgical assisted anterior lumbar interbody fusion: technical development and case report. Beutler WJ; Peppelman WC; DiMarco LA Spine (Phila Pa 1976); 2013 Feb; 38(4):356-63. PubMed ID: 22842558 [TBL] [Abstract][Full Text] [Related]
14. Safety and Efficacy of Reconstruction of Complex Cervical Spine Pathology Using Pedicle Screws Inserted with Stealth Navigation and 3D Image-Guided (O-Arm) Technology. Theologis AA; Burch S Spine (Phila Pa 1976); 2015 Sep; 40(18):1397-406. PubMed ID: 26426710 [TBL] [Abstract][Full Text] [Related]
15. Pedicle screw placement with a free hand technique in thoracolumbar spine: is it safe? Karapinar L; Erel N; Ozturk H; Altay T; Kaya A J Spinal Disord Tech; 2008 Feb; 21(1):63-7. PubMed ID: 18418139 [TBL] [Abstract][Full Text] [Related]
16. An optimal design for patient-specific templates for pedicle spine screws placement. Ferrari V; Parchi P; Condino S; Carbone M; Baluganti A; Ferrari M; Mosca F; Lisanti M Int J Med Robot; 2013 Sep; 9(3):298-304. PubMed ID: 22585638 [TBL] [Abstract][Full Text] [Related]
18. Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models. Austin MS; Vaccaro AR; Brislin B; Nachwalter R; Hilibrand AS; Albert TJ Spine (Phila Pa 1976); 2002 Nov; 27(22):2503-8. PubMed ID: 12435982 [TBL] [Abstract][Full Text] [Related]
19. Clinical accuracy of computer-assisted two-dimensional fluoroscopy for the percutaneous placement of lumbosacral pedicle screws. Ravi B; Zahrai A; Rampersaud R Spine (Phila Pa 1976); 2011 Jan; 36(1):84-91. PubMed ID: 20595927 [TBL] [Abstract][Full Text] [Related]
20. Assessment of pedicle screw placement accuracy, procedure time, and radiation exposure using a miniature robotic guidance system. Lieberman IH; Hardenbrook MA; Wang JC; Guyer RD J Spinal Disord Tech; 2012 Jul; 25(5):241-8. PubMed ID: 21602728 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]