BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

239 related articles for article (PubMed ID: 27203482)

  • 1. A dynamic oppositional biogeography-based optimization approach for time-varying electrical impedance tomography.
    Rashid A; Kim S; Liu D; Kim KY
    Physiol Meas; 2016 Jun; 37(6):820-42. PubMed ID: 27203482
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An oppositional biogeography-based optimization technique to reconstruct organ boundaries in the human thorax using electrical impedance tomography.
    Rashid A; Kim BS; Khambampati AK; Kim S; Kim KY
    Physiol Meas; 2011 Jul; 32(7):767-96. PubMed ID: 21646708
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Image reconstruction using interval simulated annealing in electrical impedance tomography.
    Martins Tde C; de Camargo ED; Lima RG; Amato MB; Tsuzuki Mde S
    IEEE Trans Biomed Eng; 2012 Jul; 59(7):1861-70. PubMed ID: 22361655
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sparse regularization for EIT reconstruction incorporating structural information derived from medical imaging.
    Gong B; Schullcke B; Krueger-Ziolek S; Mueller-Lisse U; Moeller K
    Physiol Meas; 2016 Jun; 37(6):843-62. PubMed ID: 27203627
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Image reconstruction in electrical impedance tomography based on genetic algorithm].
    Hou W; Mo Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Mar; 20(1):107-10. PubMed ID: 12744177
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Temporal image reconstruction in electrical impedance tomography.
    Adler A; Dai T; Lionheart WR
    Physiol Meas; 2007 Jul; 28(7):S1-11. PubMed ID: 17664627
    [TBL] [Abstract][Full Text] [Related]  

  • 7. EIT image reconstruction based on a hybrid FE-EFG forward method and the complete-electrode model.
    Hadinia M; Jafari R; Soleimani M
    Physiol Meas; 2016 Jun; 37(6):863-78. PubMed ID: 27203801
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dynamic imaging in electrical impedance tomography of the human chest with online transition matrix identification.
    Moura FS; Aya JC; Fleury AT; Amato MB; Lima RG
    IEEE Trans Biomed Eng; 2010 Feb; 57(2):422-31. PubMed ID: 19789101
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Image Reconstruction in Electrical Impedance Tomography Based on Structure-Aware Sparse Bayesian Learning.
    Liu S; Jia J; Zhang YD; Yang Y
    IEEE Trans Med Imaging; 2018 Sep; 37(9):2090-2102. PubMed ID: 29994084
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A bio-electromechanical imaging technique with combined electrical impedance and ultrasound tomography.
    Steiner G; Soleimani M; Watzenig D
    Physiol Meas; 2008 Jun; 29(6):S63-75. PubMed ID: 18544806
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A Kalman filter approach to track fast impedance changes in electrical impedance tomography.
    Vauhkonen M; Karjalainen PA; Kaipio JP
    IEEE Trans Biomed Eng; 1998 Apr; 45(4):486-93. PubMed ID: 9556965
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The use of the Kalman filter in the automated segmentation of EIT lung images.
    Zifan A; Liatsis P; Chapman BE
    Physiol Meas; 2013 Jun; 34(6):671-94. PubMed ID: 23719169
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dynamic electrical impedance imaging of a chest phantom using the Kalman filter.
    Kim BS; Kim KY; Kao TJ; Newell JC; Isaacson D; Saulnier GJ
    Physiol Meas; 2006 May; 27(5):S81-91. PubMed ID: 16636422
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Regularized reconstruction in electrical impedance tomography using a variance uniformization constraint.
    Cohen-Bacrie C; Goussard Y; Guardo R
    IEEE Trans Med Imaging; 1997 Oct; 16(5):562-71. PubMed ID: 9368111
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ramp-preserving denoising for conductivity image reconstruction in magnetic resonance electrical impedance tomography.
    Lee CO; Jeon K; Ahn S; Kim HJ; Woo EJ
    IEEE Trans Biomed Eng; 2011 Jul; 58(7):2038-50. PubMed ID: 21693387
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dynamic electrical impedance imaging with the interacting multiple model scheme.
    Kim KY; Kim BS; Kim MC; Kim S; Isaacson D; Newell JC
    Physiol Meas; 2005 Apr; 26(2):S217-33. PubMed ID: 15798235
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Adaptive Kaczmarz method for image reconstruction in electrical impedance tomography.
    Li T; Kao TJ; Isaacson D; Newell JC; Saulnier GJ
    Physiol Meas; 2013 Jun; 34(6):595-608. PubMed ID: 23718952
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Linearly constrained minimum variance spatial filtering for localization of conductivity changes in electrical impedance tomography.
    Fernández-Corazza M; von Ellenrieder N; Muravchik CH
    Int J Numer Method Biomed Eng; 2015 Feb; 31(2):. PubMed ID: 25598007
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Fidelity-Embedded Regularization Method for Robust Electrical Impedance Tomography.
    Lee K; Woo EJ; Seo JK
    IEEE Trans Med Imaging; 2018 Sep; 37(9):1970-1977. PubMed ID: 29035213
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Three-dimensional electrical impedance tomography: a topology optimization approach.
    Mello LA; de Lima CR; Amato MB; Lima RG; Silva EC
    IEEE Trans Biomed Eng; 2008 Feb; 55(2 Pt 1):531-40. PubMed ID: 18269988
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.