These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

240 related articles for article (PubMed ID: 27203482)

  • 21. [A hybrid reconstruction method in electrical impedance tomography based on GMRES and Tikhonov regularization].
    Wang H; Fan W; Hu L
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Aug; 26(4):701-5. PubMed ID: 19813592
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Tomographic imaging of dynamic objects with the ensemble Kalman filter.
    Butala MD; Frazin RA; Chen Y; Kamalabadi F
    IEEE Trans Image Process; 2009 Jul; 18(7):1573-87. PubMed ID: 19447717
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Compensation of modelling errors due to unknown domain boundary in electrical impedance tomography.
    Nissinen A; Kolehmainen VP; Kaipio JP
    IEEE Trans Med Imaging; 2011 Feb; 30(2):231-42. PubMed ID: 20840893
    [TBL] [Abstract][Full Text] [Related]  

  • 24. An image reconstruction algorithm for three-dimensional electrical impedance tomography.
    Le Hyaric A; Pidcock MK
    IEEE Trans Biomed Eng; 2001 Feb; 48(2):230-5. PubMed ID: 11296879
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Shape deformation in two-dimensional electrical impedance tomography.
    Boyle A; Adler A; Lionheart WR
    IEEE Trans Med Imaging; 2012 Dec; 31(12):2185-93. PubMed ID: 22711769
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Incorporating a priori anatomical information into image reconstruction in electrical impedance tomography.
    Dehghani H; Barber DC; Basarab-Horwath I
    Physiol Meas; 1999 Feb; 20(1):87-102. PubMed ID: 10374829
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Unveiling the development of intracranial injury using dynamic brain EIT: an evaluation of current reconstruction algorithms.
    Li H; Chen R; Xu C; Liu B; Tang M; Yang L; Dong X; Fu F
    Physiol Meas; 2017 Aug; 38(9):1776-1790. PubMed ID: 28714853
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Reconstructions of chest phantoms by the D-bar method for electrical impedance tomography.
    Isaacson D; Mueller JL; Newell JC; Siltanen S
    IEEE Trans Med Imaging; 2004 Jul; 23(7):821-8. PubMed ID: 15250634
    [TBL] [Abstract][Full Text] [Related]  

  • 29. B-Spline-Based Sharp Feature Preserving Shape Reconstruction Approach for Electrical Impedance Tomography.
    Liu D; Gu D; Smyl D; Deng J; Du J
    IEEE Trans Med Imaging; 2019 Nov; 38(11):2533-2544. PubMed ID: 30892203
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [The selection of Tikhonov regularization parameter in dynamic electrical impedance imaging].
    Peng Y; Mo Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Dec; 20(4):571-3. PubMed ID: 14716847
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Impedance imaging with first-order TV regularization.
    Jung YM; Yun S
    IEEE Trans Med Imaging; 2015 Jan; 34(1):193-202. PubMed ID: 25163059
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [An improved back-projection algorithm of dynamic electrical impedance tomography].
    Xu G; He W; Singer H
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2004 Oct; 21(5):761-5. PubMed ID: 15553853
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Application of electrical impedance tomography imaging technology combined with generative adversarial network in pulmonary ventilation monitoring].
    Zhao M; Liu J; Guo Z; Chen X; Zhang S; Zheng T
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2024 Feb; 41(1):105-113. PubMed ID: 38403610
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Comparison of three dynamic algorithms of electrical impedance tomography based on simulation study].
    Shuai W; Dong X; Lv X; Chao Y
    Zhongguo Yi Liao Qi Xie Za Zhi; 2012 Jan; 36(1):4-7. PubMed ID: 22571141
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Measurement-Based Domain Parameter Optimization in Electrical Impedance Tomography Imaging.
    Dusek J; Mikulka J
    Sensors (Basel); 2021 Apr; 21(7):. PubMed ID: 33916751
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of measurement and stimulation patterns in open electrical impedance tomography with scanning electrode.
    Liu J; Xiong H; Lin L; Li G
    Med Biol Eng Comput; 2015 Jul; 53(7):589-97. PubMed ID: 25773371
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Induced current magnetic resonance-electrical impedance tomography.
    Ozparlak L; Ider YZ
    Physiol Meas; 2005 Apr; 26(2):S289-305. PubMed ID: 15798242
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Optimization of measurement arrangements for magnetic detection electrical impedance tomography.
    Hao L; Li G; Lin L
    IEEE Trans Biomed Eng; 2014 Feb; 61(2):444-52. PubMed ID: 24013827
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A Post-Processing Method for Three-Dimensional Electrical Impedance Tomography.
    Martin S; Choi CTM
    Sci Rep; 2017 Aug; 7(1):7212. PubMed ID: 28775284
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Stable reconstruction of piecewise continuous plane stratified biological tissues via electrical impedance tomography.
    Dolgin M; Einziger PD
    IEEE Trans Biomed Eng; 2010 May; 57(5):1227-33. PubMed ID: 20142149
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.