These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 27208984)

  • 21. Characterization of reversible and pseudo-irreversible acetylcholinesterase inhibitors by means of an immobilized enzyme reactor.
    Bartolini M; Cavrini V; Andrisano V
    J Chromatogr A; 2007 Mar; 1144(1):102-10. PubMed ID: 17134713
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The development of an immobilized enzyme reactor containing glyceraldehyde-3-phosphate dehydrogenase from Trypanosoma cruzi: the effect of species' specific differences on the immobilization.
    Cardoso CL; de Moraes MC; Guido RV; Oliva G; Andricopulo AD; Wainer IW; Cass QB
    Analyst; 2008 Jan; 133(1):93-9. PubMed ID: 18087619
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Preparation of high efficiency and low carry-over immobilized enzymatic reactor with methacrylic acid-silica hybrid monolith as matrix for on-line protein digestion.
    Yuan H; Zhang L; Zhang Y
    J Chromatogr A; 2014 Dec; 1371():48-57. PubMed ID: 25456586
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Human recombinant beta-secretase immobilized enzyme reactor for fast hits' selection and characterization from a virtual screening library.
    De Simone A; Mancini F; Cosconati S; Marinelli L; La Pietra V; Novellino E; Andrisano V
    J Pharm Biomed Anal; 2013 Jan; 73():131-4. PubMed ID: 22502908
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Development of a rapid and detailed structural identification system with an on-line immobilized enzyme reactor integrated into LC-NMR.
    Kashima Y; Okabayashi Y
    Chem Pharm Bull (Tokyo); 2010 Mar; 58(3):423-5. PubMed ID: 20190456
    [TBL] [Abstract][Full Text] [Related]  

  • 26. On-line microfluidic immobilized-enzyme reactors: A new tool for characterizing synthetic polymers.
    Wouters B; Pirok BWJ; Soulis D; Garmendia Perticarini RC; Fokker S; van den Hurk RS; Skolimowski M; Peters RAH; Schoenmakers PJ
    Anal Chim Acta; 2019 Apr; 1053():62-69. PubMed ID: 30712570
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Characterization of therapeutic oligonucleotides by liquid chromatography.
    Goyon A; Yehl P; Zhang K
    J Pharm Biomed Anal; 2020 Apr; 182():113105. PubMed ID: 32004766
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Rapid and efficient proteolysis through laser-assisted immobilized enzyme reactors.
    Zhang P; Gao M; Zhu S; Lei J; Zhang X
    J Chromatogr A; 2011 Nov; 1218(47):8567-71. PubMed ID: 22024345
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Immobilization of matrix metalloproteinase 8 (MMP-8) for online drug screening.
    Mazzini F; Nuti E; Petri A; Rossello A
    J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Apr; 879(11-12):756-62. PubMed ID: 21397574
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Development of a chromatographic bioreactor based on immobilized beta-glucuronidase on monolithic support for the determination of dextromethorphan and dextrorphan in human urine.
    Calleri E; Marrubini G; Massolini G; Lubda D; de Fazio SS; Furlanetto S; Wainer IW; Manzo L; Caccialanza G
    J Pharm Biomed Anal; 2004 Sep; 35(5):1179-89. PubMed ID: 15336363
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Preparation and evaluation of dual-enzyme microreactor with co-immobilized trypsin and chymotrypsin.
    Meller K; Pomastowski P; Grzywiński D; Szumski M; Buszewski B
    J Chromatogr A; 2016 Apr; 1440():45-54. PubMed ID: 26947160
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Towards automation in protein digestion: Development of a monolithic trypsin immobilized reactor for highly efficient on-line digestion and analysis.
    Naldi M; Černigoj U; Štrancar A; Bartolini M
    Talanta; 2017 May; 167():143-157. PubMed ID: 28340705
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Preparation and application of immobilized enzymatic reactors for consecutive digestion with two enzymes.
    Wang B; Shangguan L; Wang S; Zhang L; Zhang W; Liu F
    J Chromatogr A; 2016 Dec; 1477():22-29. PubMed ID: 27884426
    [TBL] [Abstract][Full Text] [Related]  

  • 34. On-line synthesis utilizing immobilized enzyme reactors based upon immobilized dopamine beta-hydroxylase.
    Markoglou N; Wainer IW
    J Chromatogr B Analyt Technol Biomed Life Sci; 2002 Jan; 766(1):145-51. PubMed ID: 11820290
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Cathepsin D immobilized capillary reactors for on-flow screening assays.
    Cornelio VE; de Moraes MC; Domingues VC; Fernandes JB; da Silva MFDGF; Cass QB; Vieira PC
    J Pharm Biomed Anal; 2018 Mar; 151():252-259. PubMed ID: 29367161
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Nonionic micellar liquid chromatography coupled to immobilized enzyme reactors.
    Tomer S; Dorsey JG; Berthod A
    J Chromatogr A; 2001 Jul; 923(1-2):7-16. PubMed ID: 11510562
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Poly (N-acryloxysuccinimide-co-ethylene glycol dimethacrylate) precursor monolith and its post polymerization modification with alkyl ligands, trypsin and lectins for reversed-phase chromatography, miniaturized enzyme reactors and lectin affinity chromatography, respectively.
    Jonnada M; El Rassi Z
    Electrophoresis; 2017 Nov; 38(22-23):2870-2879. PubMed ID: 28776699
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Immobilized monolithic enzymatic reactor and its application for analysis of in-vitro fertilization media samples.
    Chen WQ; Obermayr P; Černigoj U; Vidič J; Panić-Janković T; Mitulović G
    Electrophoresis; 2017 Nov; 38(22-23):2957-2964. PubMed ID: 28613010
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Microscale immobilized enzyme reactors in proteomics: latest developments.
    Safdar M; Spross J; Jänis J
    J Chromatogr A; 2014 Jan; 1324():1-10. PubMed ID: 24360812
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comprehensive hydrophilic interaction and ion-pair reversed-phase liquid chromatography for analysis of di- to deca-oligonucleotides.
    Li Q; Lynen F; Wang J; Li H; Xu G; Sandra P
    J Chromatogr A; 2012 Sep; 1255():237-43. PubMed ID: 22204934
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.