These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
174 related articles for article (PubMed ID: 2720981)
1. Unreliable visual estimation of the incidence and amount of turbidity, hemolysis, and icterus in serum from hospitalized patients. Glick MR; Ryder KW; Glick SJ; Woods JR Clin Chem; 1989 May; 35(5):837-9. PubMed ID: 2720981 [TBL] [Abstract][Full Text] [Related]
2. The incidence rate and influence factors of hemolysis, lipemia, icterus in fasting serum biochemistry specimens. Tian G; Wu Y; Jin X; Zeng Z; Gu X; Li T; Chen X; Li G; Liu J PLoS One; 2022; 17(1):e0262748. PubMed ID: 35045128 [TBL] [Abstract][Full Text] [Related]
3. Multicenter evaluation of the interference of hemoglobin, bilirubin and lipids on Synchron LX-20 assays. Steen G; Vermeer HJ; Naus AJ; Goevaerts B; Agricola PT; Schoenmakers CH Clin Chem Lab Med; 2006; 44(4):413-9. PubMed ID: 16599834 [TBL] [Abstract][Full Text] [Related]
4. Effect of interference from hemolysis, icterus and lipemia on routine pediatric clinical chemistry assays. Agarwal S; Vargas G; Nordstrom C; Tam E; Buffone GJ; Devaraj S Clin Chim Acta; 2015 Jan; 438():241-5. PubMed ID: 25128720 [TBL] [Abstract][Full Text] [Related]
5. The influence of hemolysis, turbidity and icterus on the measurements of CK-MB, troponin I and myoglobin. Kwon HJ; Seo EJ; Min KO Clin Chem Lab Med; 2003 Mar; 41(3):360-4. PubMed ID: 12705347 [TBL] [Abstract][Full Text] [Related]
6. Correction of patient results for Beckman Coulter LX-20 assays affected by interference due to hemoglobin, bilirubin or lipids: a practical approach. Vermeer HJ; Steen G; Naus AJ; Goevaerts B; Agricola PT; Schoenmakers CH Clin Chem Lab Med; 2007; 45(1):114-9. PubMed ID: 17243928 [TBL] [Abstract][Full Text] [Related]
7. Establishing hemolysis, icterus, and lipemia interference limits for body fluid chemistry analytes measured on the Roche cobas instrument. Block DR; Lasho MA; Donato LJ; Meeusen JW Am J Clin Pathol; 2024 Oct; 162(4):356-368. PubMed ID: 38709595 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of the Preanalytical Interference of Hemoglobin, Bilirubin, or Lipids in Therapeutic Drug Monitoring Assays on Beckman Coulter AU Analyzers. Li J; Rietschlin J; Miller I; Weber C; Scheidegger M; Barringer S; Kerlin R; Williams J Lab Med; 2022 Mar; 53(2):172-176. PubMed ID: 34436600 [TBL] [Abstract][Full Text] [Related]
9. Effect of hemolysis, icterus, and lipemia on three acetaminophen assays: Potential medical consequences of false positive results. Zhang YV; Fan SL; Kellogg MD Clin Chim Acta; 2018 Dec; 487():287-292. PubMed ID: 30317020 [TBL] [Abstract][Full Text] [Related]
13. Interference in the anti-Xa heparin activity assay due to hemolysis and icterus during pediatric extracorporeal life support. Khan J; Chandler WL Artif Organs; 2019 Sep; 43(9):880-887. PubMed ID: 30964951 [TBL] [Abstract][Full Text] [Related]
14. Hemolysis, icterus and lipemia interfere with the determination of two oxidative stress biomarkers in canine serum. Perez-Montero B; Fermin-Rodriguez ML; Miro G; de Juan L; Cruz-Lopez F BMC Vet Res; 2023 Sep; 19(1):172. PubMed ID: 37741986 [TBL] [Abstract][Full Text] [Related]
15. Improvement of biosensor accuracy using an interference index detection system to minimize the interference effects caused by icterus and hemolysis in blood samples. Park S Analyst; 2019 Aug; 144(17):5223-5231. PubMed ID: 31360940 [TBL] [Abstract][Full Text] [Related]
16. [A fast determination of serum bilirubin with the interference from hemolysis and turbidity by three wavelength spectrophotometry]. Chai H; Dong YH Hua Xi Yi Ke Da Xue Xue Bao; 1989 Jun; 20(2):223-5. PubMed ID: 2591941 [TBL] [Abstract][Full Text] [Related]
17. Spectral Analysis Methods Based on Background Subtraction and Curvature Calculation Used in the Detection or Quantification of Hemolysis and Icterus in Blood-derived Clinical Samples. Huynh T; Lai MJ; Liu YL; Ly L; Gong X; Rommel KR; Young DL Cureus; 2017 Dec; 9(12):e1965. PubMed ID: 29492354 [TBL] [Abstract][Full Text] [Related]
18. Icteric human samples: Icterus index and method of estimating an interference-free value for 16 biochemical analyses. Nicolay A; Lorec AM; Gomez G; Portugal H J Clin Lab Anal; 2018 Feb; 32(2):. PubMed ID: 28397988 [TBL] [Abstract][Full Text] [Related]
19. [Haemolysis and turbidity influence on three analysis methods of quantitative determination of total and conjugated bilirubin on ADVIA 1650]. Gobert De Paepe E; Munteanu G; Schischmanoff PO; Porquet D Ann Biol Clin (Paris); 2008; 66(2):175-82. PubMed ID: 18390427 [TBL] [Abstract][Full Text] [Related]
20. Hemolysis, lipaemia and icterus in specimens for arterial blood gas analysis. Salvagno GL; Lippi G; Gelati M; Guidi GC Clin Biochem; 2012 Mar; 45(4-5):372-3. PubMed ID: 22198577 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]