These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 2721062)

  • 1. Experimental spiral fractures. An in vitro biomechanical comparison of lag-screw fixation to plate fixation.
    Cox LG; Dahners LE; Gilbert JA
    Clin Orthop Relat Res; 1989 Jun; (243):189-94. PubMed ID: 2721062
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Rigidity of pure lag-screw fixation as a function of screw inclination in an in vitro spiral osteotomy.
    Johner R; Joerger K; Cordey J; Perren SM
    Clin Orthop Relat Res; 1983 Sep; (178):74-9. PubMed ID: 6883871
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro biomechanical comparison of limited contat dynamic compression plate and locking compression plate.
    Aguila AZ; Manos JM; Orlansky AS; Todhunter RJ; Trotter EJ; Van der Meulen MC
    Vet Comp Orthop Traumatol; 2005; 18(4):220-6. PubMed ID: 16594390
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical stability of different fixation constructs for ORIF of radial neck fractures.
    Capo JT; Svach D; Ahsgar J; Orillaza NS; Sabatino CT
    Orthopedics; 2008 Oct; 31(10):. PubMed ID: 19226014
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: Sliding Hip Screw and Percutaneous Compression Plate.
    Krischak GD; Augat P; Beck A; Arand M; Baier B; Blakytny R; Gebhard F; Claes L
    Clin Biomech (Bristol, Avon); 2007 Dec; 22(10):1112-8. PubMed ID: 17900766
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dynamic compression plate fixation: a biomechanical comparison of unicortical vs bicortical distal screw fixation.
    Davenport SR; Lindsey RW; Leggon R; Miclau T; Panjabi M
    J Orthop Trauma; 1988; 2(2):146-50. PubMed ID: 3230499
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Suture versus screw fixation of displaced tibial eminence fractures: a biomechanical comparison.
    Bong MR; Romero A; Kubiak E; Iesaka K; Heywood CS; Kummer F; Rosen J; Jazrawi L
    Arthroscopy; 2005 Oct; 21(10):1172-6. PubMed ID: 16226643
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical comparison of polyaxial and uniaxial locking plate fixation in a proximal tibial gap model.
    Cullen AB; Curtiss S; Lee MA
    J Orthop Trauma; 2009 Aug; 23(7):507-13. PubMed ID: 19633460
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Biomechanical studies of the role of the interfragmentary traction screw in plate osteosynthesis exemplified by a short oblique tibial shaft fracture].
    Hopf T; Harnroongroi T
    Aktuelle Traumatol; 1986 Apr; 16(2):60-6. PubMed ID: 2871713
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Screws versus screw-plate fixation of type 2 Schatzker fractures of the lateral tibial plateau. Cadaver biomechanical study. Arthroscopy French Society].
    Boisrenoult P; Bricteux S; Beaufils P; Hardy P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Nov; 86(7):707-11. PubMed ID: 11104992
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical strength of the Peri-Loc proximal tibial plate: a comparison of all-locked versus hybrid locked/nonlocked screw configurations.
    Estes C; Rhee P; Shrader MW; Csavina K; Jacofsky MC; Jacofsky DJ
    J Orthop Trauma; 2008; 22(5):312-6. PubMed ID: 18448984
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical considerations in plate osteosynthesis: the effect of plate-to-bone compression with and without angular screw stability.
    Stoffel K; Lorenz KU; Kuster MS
    J Orthop Trauma; 2007 Jul; 21(6):362-8. PubMed ID: 17620993
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Biomechanics of plate osteosynthesis. Oblique lag screw - pretension of plates (author's transl)].
    Gotzen L; Haas N; Strohfeld G
    Unfallheilkunde; 1981 Nov; 84(11):439-43. PubMed ID: 7314299
    [No Abstract]   [Full Text] [Related]  

  • 14. [Biomechanical comparative study of three types of osteosynthesis in the treatment of supra and intercondylar fractures of the humerus in adults].
    Fornasiéri C; Staub C; Tourné Y; Rumelhart C; Saragaglia D
    Rev Chir Orthop Reparatrice Appar Mot; 1997; 83(3):237-42. PubMed ID: 9255359
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Basicervical fractures of the proximal femur. A biomechanical study of 3 internal fixation techniques.
    Blair B; Koval KJ; Kummer F; Zuckerman JD
    Clin Orthop Relat Res; 1994 Sep; (306):256-63. PubMed ID: 8070205
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mechanical evaluation of fracture fixation augmented with tricalcium phosphate bone cement in a porous osteoporotic cancellous bone model.
    Collinge C; Merk B; Lautenschlager EP
    J Orthop Trauma; 2007 Feb; 21(2):124-8. PubMed ID: 17304068
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An in vitro biomechanical comparison between prototype tapered shaft cortical bone screws and AO cortical bone screws for an equine metacarpal dynamic compression plate fixation of osteotomized equine third metacarpal bones.
    Sod GA; Hubert JD; Martin GS; Gill MS
    Vet Surg; 2006 Oct; 35(7):634-42. PubMed ID: 17026548
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Biomechanic study on length of plate in treatment of tibial shaft fracture].
    Hu X; Yang S; Xiao D; Lin B; Wang H; Xu Z; Zhao W; Zhang M
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Nov; 22(11):1323-6. PubMed ID: 19068599
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Alternative techniques in trochanteric hip fracture surgery. Clinical and biomechanical studies on the Medoff sliding plate and the Twin hook.
    Olsson O
    Acta Orthop Scand Suppl; 2000 Oct; 295():1-31. PubMed ID: 11116961
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical study of a unilocking T-plate system for prophylactic internal fixation of the radial osteocutaneous donor site using the sheep tibia model.
    Avery CM; Skidmore M; Peden A; Pan J
    Oral Oncol; 2011 Apr; 47(4):268-73. PubMed ID: 21388860
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.