These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 27210866)

  • 1. Safety of hydrophilic guidewires used for side-branch protection during stenting and proximal optimization technique in coronary bifurcation lesions.
    Chatterjee A; Brott BC; Foley R; Alli O; Sasse M; Ahmed M; Al Solaiman F; Reddy G; Ather S; Leesar MA
    Cardiovasc Revasc Med; 2016; 17(7):456-462. PubMed ID: 27210866
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Structural Damage of Jailed Guidewire During the Treatment of Coronary Bifurcation Lesions: A Microscopic Randomized Trial.
    Pan M; Ojeda S; Villanueva E; Chavarria J; Romero M; Suarez de Lezo J; Mazuelos F; Segura J; Carrasco F; Hidalgo F; Lopez Aguilera J; Rodriguez S; Puente M; Suarez de Lezo J
    JACC Cardiovasc Interv; 2016 Sep; 9(18):1917-24. PubMed ID: 27659568
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reliability and Safety of a Side-Branch Jailed Second-Generation Optical-Pressure Guidewire in a Physiology-Guided Bifurcation-PCI In Vitro Model.
    Rubimbura V; Johnson N; Van't Veer M; Adjedj J; Fournier S; Dupré M; De Bruyne B; Eeckhout E; Muller O
    J Invasive Cardiol; 2022 Aug; 34(8):E594-E600. PubMed ID: 35830360
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Provisional side branch-stenting for coronary bifurcation lesions: evidence of improving procedural and clinical outcomes with contemporary techniques.
    Mylotte D; Routledge H; Harb T; Garot P; Hovasse T; Benamer H; Unterseeh T; Chevalier B; Morice MC; Louvard Y; Lefèvre T
    Catheter Cardiovasc Interv; 2013 Oct; 82(4):E437-45. PubMed ID: 23441082
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of kissing balloon inflation on the main vessel stent volume, area, and symmetry after side-branch dilation in patients with coronary bifurcation lesions: a serial volumetric intravascular ultrasound study.
    Rahman S; Leesar T; Cilingiroglu M; Effat M; Arif I; Helmy T; Leesar MA
    JACC Cardiovasc Interv; 2013 Sep; 6(9):923-31. PubMed ID: 23954062
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Role of Proximal Optimization Technique Guided by Intravascular Ultrasound on Stent Expansion, Stent Symmetry Index, and Side-Branch Hemodynamics in Patients With Coronary Bifurcation Lesions.
    Hakim D; Chatterjee A; Alli O; Turner J; Sattar A; Foin N; Leesar MA
    Circ Cardiovasc Interv; 2017 Oct; 10(10):. PubMed ID: 29038225
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Scanning Electron Microscopic Assessment of Stent Coating Integrity in Jailed Wire Technique for Bifurcation Treatment.
    Gao L; Zhang C; Wang H; Zhang Y; Gao Z; Xu B; Chen J; Yuan J; Qiao S; Chen J
    J Interv Cardiol; 2021; 2021():2629393. PubMed ID: 34113221
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Efficacy of the proximal optimization technique on crossover stenting in coronary bifurcation lesions in the 3D-OCT bifurcation registry.
    Murasato Y; Mori T; Okamura T; Nagoshi R; Fujimura T; Yamawaki M; Ono S; Serikawa T; Nakao F; Shite J;
    Int J Cardiovasc Imaging; 2019 Jun; 35(6):981-990. PubMed ID: 30887408
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Twisting wire technique: An effective method to retrieve fractured guide wire fragments from coronary arteries.
    Devidutta S; Lim ST
    Cardiovasc Revasc Med; 2016 Jun; 17(4):282-6. PubMed ID: 27106743
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Computed tomography angiography versus angiography for guiding percutaneous coronary interventions in bifurcation lesions - A prospective randomized pilot study.
    Wolny R; Pregowski J; Kruk M; Kepka C; Mintz GS; Toth GG; Debski A; Ciszewski M; Kukula K; Opolski MP; Chmielak Z; Witkowski A
    J Cardiovasc Comput Tomogr; 2017; 11(2):119-128. PubMed ID: 28117242
    [TBL] [Abstract][Full Text] [Related]  

  • 11. One, two, three … breakdance and twist.
    Aranzulla TC
    Catheter Cardiovasc Interv; 2020 Sep; 96(3):601-608. PubMed ID: 31797536
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Feasibility and safety of jailed-pressure wire technique using durable optical fiber pressure wire for intervention of coronary bifurcation lesions.
    Omori H; Kawase Y; Hara M; Tanigaki T; Okamoto S; Hirata T; Kikuchi J; Ota H; Sobue Y; Miyake T; Kawamura I; Okubo M; Kamiya H; Tsuchiya K; Suzuki T; Pijls NHJ; Matsuo H
    Catheter Cardiovasc Interv; 2019 Aug; 94(2):E61-E66. PubMed ID: 30723996
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Successful percutaneous coronary intervention for complex bifurcated lesions with combination of "Reverse wire technique" and "Reverse bent wiring with the crusade catheter" novel wire manipulation technique.
    Nomura T; Higuchi Y; Kato T
    Catheter Cardiovasc Interv; 2016 Apr; 87(5):920-5. PubMed ID: 26490073
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Modified jailed balloon technique for bifurcation lesions.
    Saito S; Shishido K; Moriyama N; Ochiai T; Mizuno S; Yamanaka F; Sugitatsu K; Tobita K; Matsumi J; Tanaka Y; Murakami M
    Catheter Cardiovasc Interv; 2018 Sep; 92(3):E218-E226. PubMed ID: 29205789
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Usefulness of longitudinal reconstructed optical coherence tomography images for predicting the need for the reverse wire technique during coronary bifurcation interventions.
    Watanabe M; Okura H; Okamura A; Iwai S; Keshi A; Kamon D; Isojima T; Ueda T; Soeda T; Saito Y
    Catheter Cardiovasc Interv; 2019 Aug; 94(2):E54-E60. PubMed ID: 30474184
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in bifurcation lesions treated with a single-stenting technique: six-month angiographic and 12-month clinical results of the drug-eluting balloon in bifurcations trial.
    Stella PR; Belkacemi A; Dubois C; Nathoe H; Dens J; Naber C; Adriaenssens T; van Belle E; Doevendans P; Agostoni P
    Catheter Cardiovasc Interv; 2012 Dec; 80(7):1138-46. PubMed ID: 22422607
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An angiographic tool for risk prediction of side branch occlusion in coronary bifurcation intervention: the RESOLVE score system (Risk prEdiction of Side branch OccLusion in coronary bifurcation interVEntion).
    Dou K; Zhang D; Xu B; Yang Y; Yin D; Qiao S; Wu Y; Yan H; You S; Wang Y; Wu Z; Gao R; Kirtane AJ
    JACC Cardiovasc Interv; 2015 Jan; 8(1 Pt A):39-46. PubMed ID: 25616815
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Outcomes of the Tryton-dedicated bifurcation stent for the treatment of true coronary bifurcations: Individual-patient-data pooled analysis.
    Konigstein M; Srdanovic I; Gore AK; Rahim HM; Généreux P; Ben-Yehuda O; Kumsars I; Lesiak M; Kini A; Fontos G; Slagboom T; Ungi I; Christopher Metzger D; Crowley A; Leon MB; Ali ZA
    Catheter Cardiovasc Interv; 2019 Jun; 93(7):1255-1261. PubMed ID: 30489011
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Relation Between Optical Coherence Tomography-Detected Layered Pattern and Acute Side Branch Occlusion after Provisional Stenting of Coronary Bifurcation Lesions.
    Cao Y; Mintz GS; Matsumura M; Zhang W; Lin Y; Wang X; Fujino A; Lee T; Murai T; Hoshino M; Usui E; Kanaji Y; Yonetsu T; Kakuta T; Maehara A
    Cardiovasc Revasc Med; 2019 Nov; 20(11):1007-1013. PubMed ID: 30683562
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative analysis of lumen enlargement mechanisms achieved with the bifurcation dedicated BiOSS) stent versus classical coronary stent implantations by means of provisional side branch stenting strategy: an intravascular ultrasound study.
    Gil RJ; Bil J; Michałek A; Vassiliev D; Costa RA
    Int J Cardiovasc Imaging; 2013 Dec; 29(8):1667-76. PubMed ID: 23868287
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.