  • 21. Monte Carlo Calculation of Beam Quality and Phantom Scatter Corrections for Lithium Formate Electron Paramagnetic Resonance Dosimeter for High-energy Brachytherapy Dosimetry.
    Mishra S; Selvam TP
    J Med Phys; 2017; 42(2):72-79. PubMed ID: 28706352
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A Monte Carlo investigation of the dose distribution for
    Badry H; Oufni L; Ouabi H; Hirayama H
    Appl Radiat Isot; 2018 Jun; 136():104-110. PubMed ID: 29494942
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Study of encapsulated 170Tm sources for their potential use in brachytherapy.
    Ballester F; Granero D; Perez-Calatayud J; Venselaar JL; Rivard MJ
    Med Phys; 2010 Apr; 37(4):1629-37. PubMed ID: 20443484
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of
    Safigholi H; Meigooni AS; Song WY
    Med Phys; 2017 Sep; 44(9):4426-4436. PubMed ID: 28494095
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Technical note: EGSnrc-based dosimetric study of the BEBIG 60Co HDR brachytherapy sources.
    Selvam TP; Bhola S
    Med Phys; 2010 Mar; 37(3):1365-70. PubMed ID: 20384274
    [TBL] [Abstract][Full Text] [Related]  

  • 26. TLD, diode and Monte Carlo dosimetry of an 192Ir source for high dose-rate brachytherapy.
    Kirov As; Williamson JF; Meigooni AS; Zhu Y
    Phys Med Biol; 1995 Dec; 40(12):2015-36. PubMed ID: 8719942
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Monte Carlo aided dosimetry of the microselectron pulsed and high dose-rate 192Ir sources.
    Williamson JF; Li Z
    Med Phys; 1995 Jun; 22(6):809-19. PubMed ID: 7565372
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Monte Carlo dosimetry of the Buchler high dose rate 192Ir source.
    Ballester F; Pérez-Calatayud J; Puchades V; Lluch JL; Serrano-Andrés MA; Limami Y; Lliso F; Casal E
    Phys Med Biol; 2001 Mar; 46(3):N79-90. PubMed ID: 11277236
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Air-kerma strength determination of an HDR
    Smith BR; Micka JA; Aima M; DeWerd LA; Culberson WS
    Med Phys; 2017 Jan; 44(1):311-320. PubMed ID: 28102953
    [TBL] [Abstract][Full Text] [Related]  

  • 30. EGSnrc Monte Carlo-aided dosimetric studies of the new BEBIG (60)Co HDR brachytherapy source.
    Anwarul IM; Akramuzzaman MM; Zakaria GA
    J Contemp Brachytherapy; 2013 Sep; 5(3):148-56. PubMed ID: 24143150
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Technical note: Monte-Carlo dosimetry of the HDR 12i and Plus 192Ir sources.
    Ballester F; Puchades V; Lluch JL; Serrano-Andrés MA; Limami Y; Pérez-Calatayud J; Casal E
    Med Phys; 2001 Dec; 28(12):2586-91. PubMed ID: 11797964
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Monte Carlo dosimetry of the IRAsource high dose rate (192)Ir brachytherapy source.
    Sarabiasl A; Ayoobian N; Jabbari I; Poorbaygi H; Javanshir MR
    Australas Phys Eng Sci Med; 2016 Jun; 39(2):413-22. PubMed ID: 26906341
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Monte Carlo dosimetry of a new 192Ir high dose rate brachytherapy source.
    Angelopoulos A; Baras P; Sakelliou L; Karaiskos P; Sandilos P
    Med Phys; 2000 Nov; 27(11):2521-7. PubMed ID: 11128304
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance.
    Espinoza A; Beeksma B; Petasecca M; Fuduli I; Porumb C; Cutajar D; Corde S; Jackson M; Lerch ML; Rosenfeld AB
    Med Phys; 2013 Nov; 40(11):111702. PubMed ID: 24320410
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Dose characterization in the near-source region for two high dose rate brachytherapy sources.
    Wang R; Li XA
    Med Phys; 2002 Aug; 29(8):1678-86. PubMed ID: 12201413
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Radiochromic film measurement of anisotropy function for high-dose-rate Ir-192 brachytherapy source.
    Sharma SD; Bianchi C; Conte L; Novario R; Bhatt BC
    Phys Med Biol; 2004 Sep; 49(17):4065-72. PubMed ID: 15470923
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Technical note: Dosimetric study for the new BEBIG
    Elboukhari S; Yamni K; Ouabi H; Bouassa T; Ait Mlouk L
    Appl Radiat Isot; 2020 May; 159():109087. PubMed ID: 32250762
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate
    Kaveckyte V; Malusek A; Benmakhlouf H; Alm Carlsson G; Carlsson Tedgren Å
    Med Phys; 2018 Jan; 45(1):429-437. PubMed ID: 29171060
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Monte Carlo study of dosimetric parameters and dose distribution effect of inhomogeneities and source position of GammaMed Plus source.
    Chandola RM; Tiwari S; Painuly NK; Choudhary V; Azad SK; Beck M
    J Cancer Res Ther; 2011; 7(1):29-34. PubMed ID: 21546739
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism.
    Ballester F; Carlsson Tedgren Å; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith RL; Thomson RM; Verhaegen F; Vijande J; Ma Y; Beaulieu L
    Med Phys; 2015 Jun; 42(6):3048-61. PubMed ID: 26127057
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.