These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
184 related articles for article (PubMed ID: 27224934)
1. A Novel Device for the Evaluation of Hemostatic Function in Critical Care Settings. Ferrante EA; Blasier KR; Givens TB; Lloyd CA; Fischer TJ; Viola F Anesth Analg; 2016 Dec; 123(6):1372-1379. PubMed ID: 27224934 [TBL] [Abstract][Full Text] [Related]
2. Comparison of SEER Sonorheometry With Rotational Thromboelastometry and Laboratory Parameters in Cardiac Surgery. Huffmyer JL; Fernandez LG; Haghighian C; Terkawi AS; Groves DS Anesth Analg; 2016 Dec; 123(6):1390-1399. PubMed ID: 27749339 [TBL] [Abstract][Full Text] [Related]
3. A Comparison of a New Ultrasound-Based Whole Blood Viscoelastic Test (SEER Sonorheometry) Versus Thromboelastography in Cardiac Surgery. Reynolds PS; Middleton P; McCarthy H; Spiess BD Anesth Analg; 2016 Dec; 123(6):1400-1407. PubMed ID: 27159065 [TBL] [Abstract][Full Text] [Related]
5. Multicenter Evaluation of the Quantra QPlus System in Adult Patients Undergoing Major Surgical Procedures. Groves DS; Welsby IJ; Naik BI; Tanaka K; Hauck JN; Greenberg CS; Winegar DA; Viola F Anesth Analg; 2020 Apr; 130(4):899-909. PubMed ID: 32032102 [TBL] [Abstract][Full Text] [Related]
6. Comparison of the resonance sonorheometry based Quantra® system with rotational thromboelastometry ROTEM® sigma in cardiac surgery - a prospective observational study. Baulig W; Akbas S; Schütt PK; Keul W; Jovic M; Berdat P; von Felten S; Steigmiller K; Ganter MT; Theusinger OM BMC Anesthesiol; 2021 Oct; 21(1):260. PubMed ID: 34711167 [TBL] [Abstract][Full Text] [Related]
7. Coagulation monitoring: current techniques and clinical use of viscoelastic point-of-care coagulation devices. Ganter MT; Hofer CK Anesth Analg; 2008 May; 106(5):1366-75. PubMed ID: 18420846 [TBL] [Abstract][Full Text] [Related]
8. Clinical utility of the Quantra Zghaibe W; Scheuermann S; Munting K; Blaudszun G; Besser M; Ortmann E; Klein AA Anaesthesia; 2020 Mar; 75(3):366-373. PubMed ID: 31845321 [TBL] [Abstract][Full Text] [Related]
9. A novel ultrasound-based method to evaluate hemostatic function of whole blood. Viola F; Mauldin FW; Lin-Schmidt X; Haverstick DM; Lawrence MB; Walker WF Clin Chim Acta; 2010 Jan; 411(1-2):106-13. PubMed ID: 19861121 [TBL] [Abstract][Full Text] [Related]
10. Adaptive force sonorheometry for assessment of whole blood coagulation. Mauldin FW; Viola F; Hamer TC; Ahmed EM; Crawford SB; Haverstick DM; Lawrence MB; Walker WF Clin Chim Acta; 2010 May; 411(9-10):638-44. PubMed ID: 20096680 [TBL] [Abstract][Full Text] [Related]
11. Utility of whole blood hemostatometry using the clot signature analyzer for assessment of hemostasis in cardiac surgery. Faraday N; Guallar E; Sera VA; Bolton ED; Scharpf RB; Cartarius AM; Emery K; Concord J; Kickler TS Anesthesiology; 2002 May; 96(5):1115-22. PubMed ID: 11981151 [TBL] [Abstract][Full Text] [Related]
13. Evaluation and performance characteristics of the automated coagulation analyzer ACL TOP. Appert-Flory A; Fischer F; Jambou D; Toulon P Thromb Res; 2007; 120(5):733-43. PubMed ID: 17275069 [TBL] [Abstract][Full Text] [Related]
14. Sonorheometry: a noncontact method for the dynamic assessment of thrombosis. Viola F; Kramer MD; Lawrence MB; Oberhauser JP; Walker WF Ann Biomed Eng; 2004 May; 32(5):696-705. PubMed ID: 15171624 [TBL] [Abstract][Full Text] [Related]
15. The Utility of Viscoelastic Testing in Patients Undergoing IR Procedures. Reis SP; DeSimone N; Barnes L; Nordeck SM; Grewal S; Cripps M; Kalva SP J Vasc Interv Radiol; 2017 Jan; 28(1):78-87. PubMed ID: 27884687 [TBL] [Abstract][Full Text] [Related]
16. A portable blood plasma clot micro-elastometry device based on resonant acoustic spectroscopy. Krebs CR; Li L; Wolberg AS; Oldenburg AL Rev Sci Instrum; 2015 Jul; 86(7):075005. PubMed ID: 26233406 [TBL] [Abstract][Full Text] [Related]
17. Comparison of Coagulation Parameters in Arterial and Venous Blood in Cardiac Surgery Measured Using the Quantra System. Groves DS; Winegar DA; Fernandez LG; Huffmyer JL; Viola F J Cardiothorac Vasc Anesth; 2019 Apr; 33(4):976-984. PubMed ID: 30279065 [TBL] [Abstract][Full Text] [Related]
18. Perioperative monitoring of primary and secondary hemostasis in coronary artery bypass grafting. Hertfelder HJ; Bös M; Weber D; Winkler K; Hanfland P; Preusse CJ Semin Thromb Hemost; 2005; 31(4):426-40. PubMed ID: 16149021 [TBL] [Abstract][Full Text] [Related]
19. Blood rheological characterization using the thickness-shear mode resonator. Bandey HL; Cernosek RW; Lee WE; Ondrovic LE Biosens Bioelectron; 2004 Jul; 19(12):1657-65. PubMed ID: 15142600 [TBL] [Abstract][Full Text] [Related]
20. Viscoelastic coagulation testing: technology, applications, and limitations. McMichael MA; Smith SA Vet Clin Pathol; 2011 Jun; 40(2):140-53. PubMed ID: 21446994 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]