  • 1. Neutron dose equivalent outside the lateral shielding of an electron linear accelerator operating at 0.48-2.15 GeV.
    Hirayama H; Ban S
    Health Phys; 1989 Jun; 56(6):947-52. PubMed ID: 2722519
    [No Abstract]   [Full Text] [Related]  

  • 2. [Shielding design and detection of neutrons from medical and industrial electron accelerators--simple method of design calculation for neutron shielding].
    Nakamura T; Uwamino Y
    Radioisotopes; 1986 Feb; 35(2):51-6. PubMed ID: 3704202
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multileaf shielding design against neutrons produced by medical linear accelerators.
    Rebello WF; Silva AX; Facure A
    Radiat Prot Dosimetry; 2008; 128(2):227-33. PubMed ID: 17569690
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Neutron production from a mobile linear accelerator operating in electron mode for intraoperative radiation therapy.
    Loi G; Dominietto M; Cannillo B; Ciocca M; Krengli M; Mones E; Negri E; Brambilla M
    Phys Med Biol; 2006 Feb; 51(3):695-702. PubMed ID: 16424589
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Measurements of the neutron dose near a 15 Mv medical linear accelerator.
    Golnik N; Zielczynski M; Bulski W; Tulik P; Palko T
    Radiat Prot Dosimetry; 2007; 126(1-4):619-22. PubMed ID: 17513292
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Neutron pollution in roentgen beams from electron accelerators].
    Fehrentz D; Hassib GM; Spyropoulos B
    Strahlentherapie; 1983 Nov; 159(11):703-12. PubMed ID: 6658859
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Shielding evaluation of a medical linear accelerator vault in preparation for installing a high-dose rate 252Cf remote afterloader.
    Melhus CS; Rivard MJ; Kurkomelis J; Liddle CB; Massé FX
    Radiat Prot Dosimetry; 2005; 113(4):428-37. PubMed ID: 15755770
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Response of neutron detectors to high-energy mixed radiation fields.
    Mayer S; Forkel-Wirth D; Fuerstner M; Menzel HG; Mueller MJ; Perrin D; Theis C; Vincke H
    Radiat Prot Dosimetry; 2007; 125(1-4):289-92. PubMed ID: 17337743
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Shielding design and detection of neutrons from medical and industrial electron accelerators--accuracy evaluation of simple calculation method by neutron measurement].
    Nakamura T
    Radioisotopes; 1986 Feb; 35(2):57-64. PubMed ID: 3704203
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Neutron dose measurements with the GSI ball at high-energy accelerators.
    Fehrenbacher G; Gutermuth F; Kozlova E; Radon T; Schuetz R
    Radiat Prot Dosimetry; 2007; 125(1-4):209-12. PubMed ID: 16980706
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Shielding analysis of the Microtron MT-25 bunker using the MCNP-4C code and NCRP Report 51.
    Casanova AO; López N; Gelen A; Guevara MV; Díaz O; Cimino L; D'Alessandro K; Melo JC
    Radiat Prot Dosimetry; 2004; 109(3):189-95. PubMed ID: 15254322
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Neutron dose calculation at the maze entrance of medical linear accelerator rooms.
    Falcão RC; Facure A; Silva AX
    Radiat Prot Dosimetry; 2007; 123(3):283-7. PubMed ID: 17005540
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement of the fluence response of the GSI neutron ball dosemeter in the energy range from thermal to 19 MeV.
    Fehrenbacher G; Kozlova E; Gutermuth F; Radon T; Schütz R; Nolte R; Böttger R
    Radiat Prot Dosimetry; 2007; 126(1-4):546-8. PubMed ID: 17561518
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A measuring system with a recombination chamber for neutron dosimetry around medical accelerators.
    Golnik N; Kamiński P; Zielczyński M
    Radiat Prot Dosimetry; 2004; 110(1-4):273-6. PubMed ID: 15353658
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Shielding design for a laser-accelerated proton therapy system.
    Fan J; Luo W; Fourkal E; Lin T; Li J; Veltchev I; Ma CM
    Phys Med Biol; 2007 Jul; 52(13):3913-30. PubMed ID: 17664585
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Neutron shielding of the medical linac room (author's transl)].
    Toyoshima K; Yonemori M; Fukuda Y; Takada K; Hokimoto K; Fukudome S; Ohtake H
    Radioisotopes; 1981 Nov; 30(11):612-5. PubMed ID: 7335901
    [No Abstract]   [Full Text] [Related]  

  • 17. Shielding at the egress of a 23 mV linear accelerator.
    Trappier AS; Johnson LP
    J Natl Med Assoc; 1993 Mar; 85(3):205-8. PubMed ID: 8474134
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Radiation exposure of personnel during intraoperative radiotherapy (IORT): radiation protection aspects.
    Strigari L; Soriani A; Landoni V; Teodoli S; Bruzzaniti V; Benassi M
    J Exp Clin Cancer Res; 2004 Sep; 23(3):489-94. PubMed ID: 15595641
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Radiation protection aspects of a new high-energy linear accelerator.
    O'Brien P; Michaels HB; Gillies B; Aldrich JE; Andrew JW
    Med Phys; 1985; 12(1):101-7. PubMed ID: 3919249
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The neutron dose and energy spectrum outside a 20-MV accelerator treatment room.
    Muller-Runkel R; Ovadia J; Culbert H; Cooke RH; Dolecek EH
    Med Phys; 1986; 13(5):742-7. PubMed ID: 3097465
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.