These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
312 related articles for article (PubMed ID: 27232150)
1. Ultrapressure liquid chromatography-tandem mass spectrometry assay using atmospheric pressure photoionization (UPLC-APPI-MS/MS) for quantification of 4-methoxydiphenylmethane in pharmacokinetic evaluation. Farhan N; Fitzpatrick S; Shim YM; Paige M; Chow DS J Pharm Biomed Anal; 2016 Sep; 128():46-52. PubMed ID: 27232150 [TBL] [Abstract][Full Text] [Related]
2. Determination of carotenoids by liquid chromatography/mass spectrometry: effect of several dopants. Rivera S; Vilaró F; Canela R Anal Bioanal Chem; 2011 May; 400(5):1339-46. PubMed ID: 21380750 [TBL] [Abstract][Full Text] [Related]
3. Simultaneous analysis of natural pigments and E-141i in olive oils by liquid chromatography-tandem mass spectrometry. Arrizabalaga-Larrañaga A; Rodríguez P; Medina M; Santos FJ; Moyano E Anal Bioanal Chem; 2019 Aug; 411(21):5577-5591. PubMed ID: 31172239 [TBL] [Abstract][Full Text] [Related]
4. On-line solid phase extraction-liquid chromatography-tandem mass spectrometry for insect repellent residue analysis in surface waters using atmospheric pressure photoionization. Molins-Delgado D; García-Sillero D; Díaz-Cruz MS; Barceló D J Chromatogr A; 2018 Apr; 1544():33-40. PubMed ID: 29502900 [TBL] [Abstract][Full Text] [Related]
5. Comparison of electrospray ionization, atmospheric pressure chemical ionization, and atmospheric pressure photoionization for the analysis of dinitropyrene and aminonitropyrene LC-MS/MS. Straube EA; Dekant W; Völkel W J Am Soc Mass Spectrom; 2004 Dec; 15(12):1853-62. PubMed ID: 15589761 [TBL] [Abstract][Full Text] [Related]
6. Plasma metabolome analysis by integrated ionization rapid-resolution liquid chromatography/tandem mass spectrometry. Tian H; Bai J; An Z; Chen Y; Zhang R; He J; Bi X; Song Y; Abliz Z Rapid Commun Mass Spectrom; 2013 Sep; 27(18):2071-80. PubMed ID: 23943328 [TBL] [Abstract][Full Text] [Related]
7. Comparison of atmospheric pressure chemical ionization, electrospray ionization, and atmospheric pressure photoionization for the determination of cyclosporin A in rat plasma. Wang G; Hsieh Y; Korfmacher WA Anal Chem; 2005 Jan; 77(2):541-8. PubMed ID: 15649051 [TBL] [Abstract][Full Text] [Related]
8. Anisole, a new dopant for atmospheric pressure photoionization mass spectrometry of low proton affinity, low ionization energy compounds. Kauppila TJ; Kostiainen R; Bruins AP Rapid Commun Mass Spectrom; 2004; 18(7):808-15. PubMed ID: 15052564 [TBL] [Abstract][Full Text] [Related]
9. Determination of estrogenic compounds in wastewater using liquid chromatography-tandem mass spectrometry with electrospray and atmospheric pressure photoionization following desalting extraction. Chen HC; Kuo HW; Ding WH Chemosphere; 2009 Jan; 74(4):508-14. PubMed ID: 18996561 [TBL] [Abstract][Full Text] [Related]
10. Comparison of electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization for determining estrogenic chemicals in water by liquid chromatography tandem mass spectrometry with chemical derivatizations. Lien GW; Chen CY; Wang GS J Chromatogr A; 2009 Feb; 1216(6):956-66. PubMed ID: 19118834 [TBL] [Abstract][Full Text] [Related]
11. High-performance liquid chromatography-atmospheric pressure photoionization/tandem mass spectrometry for the detection of 17alpha-ethinylestradiol in hepatocytes. Li F; Hsieh Y; Korfmacher WA J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Jul; 870(2):186-91. PubMed ID: 18603489 [TBL] [Abstract][Full Text] [Related]
12. Laser diode thermal desorption atmospheric pressure chemical ionization tandem mass spectrometry applied for the ultra-fast quantitative analysis of BKM120 in human plasma. Lanshoeft C; Heudi O; Leuthold LA; Schlotterbeck G; Elbast W; Picard F; Kretz O Anal Bioanal Chem; 2014 Sep; 406(22):5413-23. PubMed ID: 24958346 [TBL] [Abstract][Full Text] [Related]
13. Analysis of pentacyclic triterpenes by LC-MS. A comparative study between APCI and APPI. Rhourri-Frih B; Chaimbault P; Claude B; Lamy C; André P; Lafosse M J Mass Spectrom; 2009 Jan; 44(1):71-80. PubMed ID: 18946879 [TBL] [Abstract][Full Text] [Related]
14. Comparison of electrospray ionization and atmospheric pressure photoionization liquid chromatography mass spectrometry methods for analysis of ergot alkaloids from endophyte-infected sleepygrass (Achnatherum robustum). Jarmusch AK; Musso AM; Shymanovich T; Jarmusch SA; Weavil MJ; Lovin ME; Ehrmann BM; Saari S; Nichols DE; Faeth SH; Cech NB J Pharm Biomed Anal; 2016 Jan; 117():11-7. PubMed ID: 26340558 [TBL] [Abstract][Full Text] [Related]
15. Comparison of electrospray ionization, atmospheric pressure photoionization, and anion attachment atmospheric pressure photoionization for the analysis of hexabromocyclododecane enantiomers in environmental samples. Ross MS; Wong CS J Chromatogr A; 2010 Dec; 1217(50):7855-63. PubMed ID: 21071034 [TBL] [Abstract][Full Text] [Related]
16. Determination of 17 illicit drugs in oral fluid using isotope dilution ultra-high performance liquid chromatography/tandem mass spectrometry with three atmospheric pressure ionizations. Wang IT; Feng YT; Chen CY J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Nov; 878(30):3095-105. PubMed ID: 20951654 [TBL] [Abstract][Full Text] [Related]
17. Liquid chromatography-electrospray ionization-tandem mass spectrometry method for quantitative estimation of new imiqualine leads with potent anticancer activities in rat and mouse plasma. Application to a pharmacokinetic study in mice. Chouchou A; Marion B; Enjalbal C; Roques C; Cuq P; Bonnet PA; Bressolle-Gomeni FMM; Deleuze-Masquéfa C J Pharm Biomed Anal; 2018 Jan; 148():369-379. PubMed ID: 29111492 [TBL] [Abstract][Full Text] [Related]
18. Dopant assisted-atmospheric pressure photoionization (DA-APPI) liquid chromatography-mass spectrometry for the quantification of 27-hydroxycholesterol in plasma. Karuna R; von Eckardstein A; Rentsch KM J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Jan; 877(3):261-8. PubMed ID: 19121981 [TBL] [Abstract][Full Text] [Related]
19. Comparison of multiple API techniques for the simultaneous detection of microconstituents in water by on-line SPE-LC-MS/MS. Wang C; Gardinali PR J Mass Spectrom; 2012 Oct; 47(10):1255-68. PubMed ID: 23019157 [TBL] [Abstract][Full Text] [Related]
20. Advantages of atmospheric pressure photoionization mass spectrometry in support of drug discovery. Cai Y; Kingery D; McConnell O; Bach AC Rapid Commun Mass Spectrom; 2005; 19(12):1717-24. PubMed ID: 15912481 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]