BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 27235673)

  • 1. Hemolysis rates in blood samples: differences between blood collected by clinicians and nurses and the effect of phlebotomy training.
    Cadamuro J; von Meyer A; Wiedemann H; Klaus Felder T; Moser F; Kipman U; Haschke-Becher E; Mrazek C; Simundic AM
    Clin Chem Lab Med; 2016 Dec; 54(12):1987-1992. PubMed ID: 27235673
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reducing preanalytical laboratory sample errors through educational and technological interventions.
    Lillo R; Salinas M; Lopez-Garrigos M; Naranjo-Santana Y; Gutiérrez M; Marín MD; Miralles M; Uris J
    Clin Lab; 2012; 58(9-10):911-7. PubMed ID: 23163106
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Minor improvement of venous blood specimen collection practices in primary health care after a large-scale educational intervention.
    Bölenius K; Söderberg J; Hultdin J; Lindkvist M; Brulin C; Grankvist K
    Clin Chem Lab Med; 2013 Feb; 51(2):303-10. PubMed ID: 23096106
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Factors affecting hemolysis rates in blood samples drawn from newly placed IV sites in the emergency department.
    Dugan L; Leech L; Speroni KG; Corriher J
    J Emerg Nurs; 2005 Aug; 31(4):338-45. PubMed ID: 16126097
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hemolysis from a nurses' standpoint--survey from four Croatian hospitals.
    Dorotić A; Antončić D; Biljak VR; Nedić D; Beletić A
    Biochem Med (Zagreb); 2015; 25(3):393-400. PubMed ID: 26525069
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Level of confidence in venepuncture and knowledge in determining causes of blood sample haemolysis among clinical staff and phlebotomists.
    Makhumula-Nkhoma N; Whittaker V; McSherry R
    J Clin Nurs; 2015 Feb; 24(3-4):370-85. PubMed ID: 24810794
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories.
    Lippi G; Plebani M; Di Somma S; Cervellin G
    Crit Rev Clin Lab Sci; 2011; 48(3):143-53. PubMed ID: 21875312
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reference range of hemolysis index in serum and lithium-heparin plasma measured with two analytical platforms in a population of unselected outpatients.
    Lippi G; Giavarina D; Gelati M; Salvagno GL
    Clin Chim Acta; 2014 Feb; 429():143-6. PubMed ID: 24362229
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Nursing blood specimen collection techniques and hemolysis rates in an emergency department: analysis of venipuncture versus intravenous catheter collection techniques.
    Lowe G; Stike R; Pollack M; Bosley J; O'Brien P; Hake A; Landis G; Billings N; Gordon P; Manzella S; Stover T
    J Emerg Nurs; 2008 Feb; 34(1):26-32. PubMed ID: 18237663
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Can the Roche hemolysis index be used for automated determination of cell-free hemoglobin? A comparison to photometric assays.
    Petrova DT; Cocisiu GA; Eberle C; Rhode KH; Brandhorst G; Walson PD; Oellerich M
    Clin Biochem; 2013 Sep; 46(13-14):1298-301. PubMed ID: 23830841
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hemolysis of coagulation specimens: a comparative study of intravenous draw methods.
    Stauss M; Sherman B; Pugh L; Parone D; Looby-Rodriguez K; Bell A; Reed CR
    J Emerg Nurs; 2012 Jan; 38(1):15-21. PubMed ID: 22226132
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Variation in phlebotomy techniques in emergency medicine and the incidence of haemolysed samples.
    Berg JE; Ahee P; Berg JD
    Ann Clin Biochem; 2011 Nov; 48(Pt 6):562-5. PubMed ID: 21948490
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of peripheral IV based blood collection on catheter dwell time, blood collection, and patient response.
    Mulloy DF; Lee SM; Gregas M; Hoffman KE; Ashley SW
    Appl Nurs Res; 2018 Apr; 40():76-79. PubMed ID: 29579503
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The relationship between vacuum and hemolysis during catheter blood collection: a retrospective analysis of six large cohorts.
    Mrazek C; Simundic AM; Wiedemann H; Krahmer F; Felder TK; Kipman U; Hoppe U; Haschke-Becher E; Cadamuro J
    Clin Chem Lab Med; 2017 Jul; 55(8):1129-1134. PubMed ID: 28107171
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Confidence level in venipuncture and knowledge on causes of in vitro hemolysis among healthcare professionals.
    Milutinović D; Andrijević I; Ličina M; Andrijević L
    Biochem Med (Zagreb); 2015; 25(3):401-9. PubMed ID: 26527124
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reducing blood sample hemolysis at a tertiary hospital emergency department.
    Ong ME; Chan YH; Lim CS
    Am J Med; 2009 Nov; 122(11):1054.e1-6. PubMed ID: 19854334
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [A comparison of the rates of hemolysis and repeated blood sampling using syringe needles versus vacuum tube needles in the emergency department].
    Sung YH; Hwang MS; Lee JH; Park HD; Ryu KH; Cho MS; Yi YH; Song S
    J Korean Acad Nurs; 2012 Jun; 42(3):443-51. PubMed ID: 22854557
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Survey of national guidelines, education and training on phlebotomy in 28 European countries: an original report by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PA).
    Simundic AM; Cornes M; Grankvist K; Lippi G; Nybo M; Kovalevskaya S; Sprongl L; Sumarac Z; Church S
    Clin Chem Lab Med; 2013 Aug; 51(8):1585-93. PubMed ID: 23729577
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A quality improvement cycle: hemolyzed specimens in the emergency department.
    Pretlow L; Gandy T; Leibach EK; Russell B; Kraj B
    Clin Lab Sci; 2008; 21(4):219-24. PubMed ID: 19174982
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [The procedure of phlebotomy for clinical laboratory studies: perspectives of development of pre-analytical stage of laboratory process].
    Kovalevskaia SN; Khorovskaia LA; Petrova NG
    Klin Lab Diagn; 2014 Aug; 59(8):61-4. PubMed ID: 25552057
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.