These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

99 related articles for article (PubMed ID: 27238632)

  • 21. Quantification of myocardial blood flow with cardiovascular magnetic resonance throughout the cardiac cycle.
    Motwani M; Kidambi A; Uddin A; Sourbron S; Greenwood JP; Plein S
    J Cardiovasc Magn Reson; 2015 Jan; 17(1):4. PubMed ID: 25630861
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Myocardial arterial spin labeling.
    Kober F; Jao T; Troalen T; Nayak KS
    J Cardiovasc Magn Reson; 2016 Apr; 18():22. PubMed ID: 27071861
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Quantification of myocardial perfusion with self-gated cardiovascular magnetic resonance.
    Likhite D; Adluru G; Hu N; McGann C; DiBella E
    J Cardiovasc Magn Reson; 2015 Feb; 17(1):14. PubMed ID: 25827080
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Measuring Knee Bone Marrow Perfusion Using Arterial Spin Labeling at 3 T.
    Li X; Johnson CP; Ellermann J
    Sci Rep; 2020 Mar; 10(1):5260. PubMed ID: 32210271
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Reproducibility of multiphase pseudo-continuous arterial spin labeling and the effect of post-processing analysis methods.
    Fazlollahi A; Bourgeat P; Liang X; Meriaudeau F; Connelly A; Salvado O; Calamante F
    Neuroimage; 2015 Aug; 117():191-201. PubMed ID: 26026814
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Multislice cardiac arterial spin labeling using improved myocardial perfusion quantification with simultaneously measured blood pool input function.
    Campbell-Washburn AE; Zhang H; Siow BM; Price AN; Lythgoe MF; Ordidge RJ; Thomas DL
    Magn Reson Med; 2013 Oct; 70(4):1125-36. PubMed ID: 23168945
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Non-contrast myocardial perfusion using a novel 4D magnetic resonance arterial spin labeling technique: initial experience.
    Miyazaki M; Zhou X; Hoshino T; Yokoyama K; Ishimura R; Nitatori T
    Microvasc Res; 2015 Mar; 98():94-101. PubMed ID: 25645290
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Improved velocity-selective labeling pulses for myocardial ASL.
    Landes V; Javed A; Jao T; Qin Q; Nayak K
    Magn Reson Med; 2020 Oct; 84(4):1909-1918. PubMed ID: 32173909
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Pediatric perfusion imaging using pulsed arterial spin labeling.
    Wang J; Licht DJ; Jahng GH; Liu CS; Rubin JT; Haselgrove J; Zimmerman RA; Detre JA
    J Magn Reson Imaging; 2003 Oct; 18(4):404-13. PubMed ID: 14508776
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Absolute Versus Relative Myocardial Blood Flow by Dynamic CT Myocardial Perfusion Imaging in Patients With Anatomic Coronary Artery Disease.
    Wichmann JL; Meinel FG; Schoepf UJ; Lo GG; Choe YH; Wang Y; Vliegenthart R; Varga-Szemes A; Muscogiuri G; Cannaò PM; De Cecco CN
    AJR Am J Roentgenol; 2015 Jul; 205(1):W67-72. PubMed ID: 26102420
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Multiple boli arterial spin labeling for high signal-to-noise rodent brain perfusion imaging.
    Vallatos A; Gilmour L; Chalmers AJ; Holmes WM
    Magn Reson Med; 2018 Feb; 79(2):1020-1030. PubMed ID: 28516482
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Assessment of absolute Tc-99m tetrofosmin retention in the myocardium as an index of myocardial blood flow and coronary flow reserve by gated-SPECT/CT: a feasibility study.
    Apostolopoulos DJ; Kaspiri A; Spyridonidis T; Patsouras N; Savvopoulos CA; Davlouros P; Vassilakos PJ; Alexopoulos D
    Ann Nucl Med; 2015 Aug; 29(7):588-602. PubMed ID: 25971450
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Measurement of brain perfusion in newborns: pulsed arterial spin labeling (PASL) versus pseudo-continuous arterial spin labeling (pCASL).
    Boudes E; Gilbert G; Leppert IR; Tan X; Pike GB; Saint-Martin C; Wintermark P
    Neuroimage Clin; 2014; 6():126-33. PubMed ID: 25379424
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Myocardial microcirculation in humans--new approaches using MRI].
    Wacker CM; Bauer WR
    Herz; 2003 Mar; 28(2):74-81. PubMed ID: 12669220
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Ischemic burden by 3-dimensional myocardial perfusion cardiovascular magnetic resonance: comparison with myocardial perfusion scintigraphy.
    Jogiya R; Morton G; De Silva K; Reyes E; Hachamovitch R; Kozerke S; Nagel E; Underwood SR; Plein S
    Circ Cardiovasc Imaging; 2014 Jul; 7(4):647-54. PubMed ID: 24867884
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Dynamic CT myocardial perfusion measurements of resting and hyperaemic blood flow in low-risk subjects with 128-slice dual-source CT.
    Ho KT; Ong HY; Tan G; Yong QW
    Eur Heart J Cardiovasc Imaging; 2015 Mar; 16(3):300-6. PubMed ID: 25378472
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Myocardial Perfusion Reserve and Strain-Encoded CMR for Evaluation of Cardiac Allograft Microvasculopathy.
    Erbel C; Mukhammadaminova N; Gleissner CA; Osman NF; Hofmann NP; Steuer C; Akhavanpoor M; Wangler S; Celik S; Doesch AO; Voss A; Buss SJ; Schnabel PA; Katus HA; Korosoglou G
    JACC Cardiovasc Imaging; 2016 Mar; 9(3):255-66. PubMed ID: 26965729
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Arterial spin-labeling magnetic resonance imaging after revascularization of moyamoya disease.
    Sugino T; Mikami T; Miyata K; Suzuki K; Houkin K; Mikuni N
    J Stroke Cerebrovasc Dis; 2013 Aug; 22(6):811-6. PubMed ID: 22721824
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Quantification of perfusion in murine myocardium: A retrospectively triggered T1 -based ASL method using model-based reconstruction.
    Gutjahr FT; Kampf T; Winter P; Meyer CB; Williams T; Jakob PM; Bauer WR; Ziener CH; Helluy X
    Magn Reson Med; 2015 Dec; 74(6):1705-15. PubMed ID: 25446550
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Analysis of myocardial perfusion parameters in an ex-vivo porcine heart model using third generation dual-source CT.
    Pelgrim GJ; Duguay TM; Stijnen JM; Varga-Szemes A; Van Tuijl S; Schoepf UJ; Oudkerk M; Vliegenthart R
    J Cardiovasc Comput Tomogr; 2017; 11(2):141-147. PubMed ID: 28202246
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.