These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

87 related articles for article (PubMed ID: 27240362)

  • 1. X-ray Photon Counting and Two-Color X-ray Imaging Using Indirect Detection.
    Dierickx B; Yao Q; Witvrouwen N; Uwaerts D; Vandewiele S; Gao P
    Sensors (Basel); 2016 May; 16(6):. PubMed ID: 27240362
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Spatio-energetic cross-talk in photon counting detectors: N × N binning and sub-pixel masking.
    Taguchi K; Stierstorfer K; Polster C; Lee O; Kappler S
    Med Phys; 2018 Nov; 45(11):4822-4843. PubMed ID: 30136278
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Photon counting multienergy x-ray imaging: effect of the characteristic x rays on detector performance.
    Shikhaliev PM; Fritz SG; Chapman JW
    Med Phys; 2009 Nov; 36(11):5107-19. PubMed ID: 19994521
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Tilted angle CZT detector for photon counting/energy weighting x-ray and CT imaging.
    Shikhaliev PM
    Phys Med Biol; 2006 Sep; 51(17):4267-87. PubMed ID: 16912381
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Projection x-ray imaging with photon energy weighting: experimental evaluation with a prototype detector.
    Shikhaliev PM
    Phys Med Biol; 2009 Aug; 54(16):4971-92. PubMed ID: 19641240
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sensitivity of photon-counting based K-edge imaging in X-ray computed tomography.
    Roessl E; Brendel B; Engel KJ; Schlomka JP; Thran A; Proksa R
    IEEE Trans Med Imaging; 2011 Sep; 30(9):1678-90. PubMed ID: 21507770
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A pixel detector-based single photon-counting system as fast spectrometer for diagnostic X-ray beams.
    Carpentieri C; Bisogni MG; Del Guerra A; Delogu P; Fantacci ME; Fogli J; Marchi A; Marzulli V; Rosso V; Stefanini A; Tofani A
    Radiat Prot Dosimetry; 2008; 129(1-3):119-22. PubMed ID: 18487616
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography.
    Hoerner MR; Stepusin EJ; Hyer DE; Hintenlang DE
    Med Phys; 2015 Mar; 42(3):1268-79. PubMed ID: 25735282
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characterization of energy response for photon-counting detectors using x-ray fluorescence.
    Ding H; Cho HM; Barber WC; Iwanczyk JS; Molloi S
    Med Phys; 2014 Dec; 41(12):121902. PubMed ID: 25471962
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Megapixel photon-counting color imaging using quanta image sensor.
    Gnanasambandam A; Elgendy O; Ma J; Chan SH
    Opt Express; 2019 Jun; 27(12):17298-17310. PubMed ID: 31252942
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Imaging performance comparison between a LaBr3: Ce scintillator based and a CdTe semiconductor based photon counting compact gamma camera.
    Russo P; Mettivier G; Pani R; Pellegrini R; Cinti MN; Bennati P
    Med Phys; 2009 Apr; 36(4):1298-317. PubMed ID: 19472638
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application.
    Shikhaliev PM; Fritz SG
    Phys Med Biol; 2011 Apr; 56(7):1905-30. PubMed ID: 21364268
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Towards hybrid pixel detectors for energy-dispersive or soft X-ray photon science.
    Jungmann-Smith JH; Bergamaschi A; Brückner M; Cartier S; Dinapoli R; Greiffenberg D; Huthwelker T; Maliakal D; Mayilyan D; Medjoubi K; Mezza D; Mozzanica A; Ramilli M; Ruder Ch; Schädler L; Schmitt B; Shi X; Tinti G
    J Synchrotron Radiat; 2016 Mar; 23(2):385-94. PubMed ID: 26917124
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A comparative study of a dual-energy-like imaging technique based on counting-integrating readout.
    Roessl E; Herrmann C; Kraft E; Proksa R
    Med Phys; 2011 Dec; 38(12):6416-28. PubMed ID: 22149825
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pulse pileup statistics for energy discriminating photon counting x-ray detectors.
    Wang AS; Harrison D; Lobastov V; Tkaczyk JE
    Med Phys; 2011 Jul; 38(7):4265-75. PubMed ID: 21859028
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An efficient computational approach to model statistical correlations in photon counting x-ray detectors.
    Faby S; Maier J; Sawall S; Simons D; Schlemmer HP; Lell M; Kachelrieß M
    Med Phys; 2016 Jul; 43(7):3945. PubMed ID: 27370113
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Amorphous In-Ga-Zn-O thin-film transistor active pixel sensor x-ray imager for digital breast tomosynthesis.
    Zhao C; Kanicki J
    Med Phys; 2014 Sep; 41(9):091902. PubMed ID: 25186389
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications.
    Barber WC; Wessel JC; Nygard E; Iwanczyk JS
    Nucl Instrum Methods Phys Res A; 2015 Jun; 784():531-537. PubMed ID: 25937684
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance simulation of an x-ray detector for spectral CT with combined Si and Cd[Zn]Te detection layers.
    Herrmann C; Engel KJ; Wiegert J
    Phys Med Biol; 2010 Dec; 55(24):7697-713. PubMed ID: 21113093
    [TBL] [Abstract][Full Text] [Related]  

  • 20. X-ray imaging performance of scintillator-filled silicon pore arrays.
    Simon M; Engel KJ; Menser B; Badel X; Linnros J
    Med Phys; 2008 Mar; 35(3):968-81. PubMed ID: 18404933
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.