These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

261 related articles for article (PubMed ID: 27244585)

  • 1. A non-contact approach for PWV detection: application in a clinical setting.
    Campo A; Heuten H; Goovaerts I; Ennekens G; Vrints C; Dirckx J
    Physiol Meas; 2016 Jul; 37(7):990-1003. PubMed ID: 27244585
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison between Regional and Local Pulse-Wave Velocity Data.
    Simova I; Katova T; Santoro C; Galderisi M
    Echocardiography; 2016 Jan; 33(1):77-81. PubMed ID: 26053566
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Arterial Wall Characteristics in Patients With Peripheral Arterial Disease. Preliminary Data Obtained at Different Arterial Sites by Radiofrequency-Based Wall Tracking System.
    Valerio F; Stefano P; Michaela K; Santo SS
    Angiology; 2018 May; 69(5):431-437. PubMed ID: 28875710
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Is local stiffness, as measured by radio frequency, more sensitive than intima-media thickness?
    Novo G; Di Miceli R; Novo S
    Int Angiol; 2013 Dec; 32(6):575-80. PubMed ID: 24212290
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Noninvasive method for measuring local pulse wave velocity by dual pulse wave Doppler: in vitro and in vivo studies.
    Wang Z; Yang Y; Yuan LJ; Liu J; Duan YY; Cao TS
    PLoS One; 2015; 10(3):e0120482. PubMed ID: 25786124
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Associations between common carotid artery diameter, Framingham risk score and cardiovascular events.
    Kozakova M; Morizzo C; La Carrubba S; Fabiani I; Della Latta D; Jamagidze J; Chiappino D; Di Bello V; Palombo C
    Nutr Metab Cardiovasc Dis; 2017 Apr; 27(4):329-334. PubMed ID: 28242234
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Increased carotid-femoral pulse wave velocity and common carotid artery intima-media thickness obtained to assess target organ damage in hypertensive patients are closely related.
    Sumbul HE; Koc AS; Demirtas D
    Clin Exp Hypertens; 2019; 41(5):466-473. PubMed ID: 30141974
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of Different Pulse Waveforms for Local Pulse Wave Velocity Measurement in Healthy and Hypertensive Common Carotid Arteries in Vivo.
    Huang C; Su Y; Zhang H; Qian LX; Luo J
    Ultrasound Med Biol; 2016 May; 42(5):1111-23. PubMed ID: 26924694
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrasonic assessment of liver stiffness and carotid artery elasticity in patients with chronic viral hepatitis.
    Li JH; Zhu N; Min YB; Shi XZ; Duan YY; Yang YL
    BMC Gastroenterol; 2018 Dec; 18(1):181. PubMed ID: 30518330
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Carotid Artery Stiffness Assessment by Ultrafast Ultrasound Imaging: Feasibility and Potential Influencing Factors.
    Pan FS; Yu L; Luo J; Wu RD; Xu M; Liang JY; Zheng YL; Xie XY
    J Ultrasound Med; 2018 Dec; 37(12):2759-2767. PubMed ID: 29672890
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Arterial wall elasticity: state of the art and future prospects.
    Messas E; Pernot M; Couade M
    Diagn Interv Imaging; 2013 May; 94(5):561-9. PubMed ID: 23619291
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of subclinical atherosclerosis by ultrasound radiofrequency data technology in patients with primary Sjögren's syndrome.
    Ozisler C; Kaplanoglu H
    Clin Rheumatol; 2019 Mar; 38(3):709-717. PubMed ID: 30334118
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Unreliable Estimation of Aortic Pulse Wave Velocity Provided by the Mobil-O-Graph Algorithm-Based System in Marfan Syndrome.
    Salvi P; Furlanis G; Grillo A; Pini A; Salvi L; Marelli S; Rovina M; Moretti F; Gaetano R; Pintassilgo I; Faini A; Fabris B; Carretta R; Parati G
    J Am Heart Assoc; 2019 May; 8(9):e04028. PubMed ID: 31020905
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A mismatch between aortic pulse pressure and pulse wave velocity predicts advanced peripheral arterial disease.
    Brand M; Woodiwiss AJ; Michel F; Booysen HL; Veller MG; Norton GR
    Eur J Vasc Endovasc Surg; 2013 Sep; 46(3):338-46. PubMed ID: 23835110
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An invasive but simple and accurate method for ascending aorta-femoral artery pulse wave velocity measurement.
    Kilic H; Yelgec S; Salih O; Akdemir R; Karakurt O; Cagirci G; Yeter E; Acikel S; Dogan M; Arslantas U; Baha RM
    Blood Press; 2013 Feb; 22(1):45-50. PubMed ID: 22747433
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Association of serum fibroblast growth factor-23 with Doppler pulse wave velocity in hemodialysis patients.
    Ibrahim WH; Ahmad AB; Sayed NG
    Saudi J Kidney Dis Transpl; 2018; 29(1):95-100. PubMed ID: 29456213
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Applanation tonometry in mice: a novel noninvasive technique to assess pulse wave velocity and arterial stiffness.
    Leloup AJ; Fransen P; Van Hove CE; Demolder M; De Keulenaer GW; Schrijvers DM
    Hypertension; 2014 Jul; 64(1):195-200. PubMed ID: 24752435
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of inaccuracies in arterial path length measurement on differences in MRI and tonometry measured pulse wave velocity.
    Weir-McCall JR; Khan F; Cassidy DB; Thakur A; Summersgill J; Matthew SZ; Adams F; Dove F; Gandy SJ; Colhoun HM; Belch JJ; Houston JG
    BMC Cardiovasc Disord; 2017 May; 17(1):118. PubMed ID: 28486936
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Single-source PPG-based local pulse wave velocity measurement: a potential cuffless blood pressure estimation technique.
    Nabeel PM; Jayaraj J; Mohanasankar S
    Physiol Meas; 2017 Nov; 38(12):2122-2140. PubMed ID: 29058686
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A prospective observational study comparing a non-operator dependent automatic PWV analyser to pulse pressure, in assessing arterial stiffness in hemodialysis.
    Salvadé I; Schätti-Stählin S; Violetti E; Schönholzer C; Cereghetti C; Zwahlen H; Berwert L; Burnier M; Gabutti L
    BMC Nephrol; 2015 Apr; 16():62. PubMed ID: 25904000
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.