BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

351 related articles for article (PubMed ID: 27247002)

  • 1. Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values.
    Das M; Loveday JJ; Wynn GJ; Gomes S; Saeed Y; Bonnett LJ; Waktare JEP; Todd DM; Hall MCS; Snowdon RL; Modi S; Gupta D
    Europace; 2017 May; 19(5):775-783. PubMed ID: 27247002
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reablated Sites of Acute Reconnection After Pulmonary Vein Isolation Do Not Predict Sites of Late Reconnection at Repeat Electrophysiology Study.
    DAS M; Wynn GJ; Morgan M; Ronayne C; Waktare JE; Todd DM; Hall MC; Snowdon RL; Modi S; Gupta D
    J Cardiovasc Electrophysiol; 2016 Apr; 27(4):381-9. PubMed ID: 26786052
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impact of local left atrial wall thickness on the incidence of acute pulmonary vein reconnection after Ablation Index-guided atrial fibrillation ablation.
    Mulder MJ; Kemme MJB; Hagen AMD; Hopman LHGA; van de Ven PM; Hauer HA; Tahapary GJM; Götte MJW; van Rossum AC; Allaart CP
    Int J Cardiol Heart Vasc; 2020 Aug; 29():100574. PubMed ID: 32642554
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prospective use of Ablation Index targets improves clinical outcomes following ablation for atrial fibrillation.
    Hussein A; Das M; Chaturvedi V; Asfour IK; Daryanani N; Morgan M; Ronayne C; Shaw M; Snowdon R; Gupta D
    J Cardiovasc Electrophysiol; 2017 Sep; 28(9):1037-1047. PubMed ID: 28639728
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Analysis of late reconnections after pulmonary vein isolation: Impact of interlesion contiguity and ablation index.
    Pedrote A; Acosta J; Frutos-López M; Jáuregui-Garrido B; Alarcón F; Arana-Rueda E
    Pacing Clin Electrophysiol; 2019 Jun; 42(6):678-685. PubMed ID: 30912154
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Three-year outcomes and reconnection patterns after initial contact force guided pulmonary vein isolation for paroxysmal atrial fibrillation.
    Nair GM; Yeo C; MacDonald Z; Ainslie MP; Alqarawi WA; Nery PB; Redpath CJ; Sadek M; Spence S; Green MS; Birnie DH
    J Cardiovasc Electrophysiol; 2017 Sep; 28(9):984-993. PubMed ID: 28635046
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Tailored ablation index for pulmonary vein isolation according to wall thickness within the ablation circle.
    Wang Y; Zhou G; Chen S; Wei Y; Lu X; Xu J; Wu X; Liu S
    Pacing Clin Electrophysiol; 2021 Apr; 44(4):575-585. PubMed ID: 33184894
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrophysiological findings following pulmonary vein isolation using radiofrequency catheter guided by contact-force and second-generation cryoballoon: lessons from repeat ablation procedures.
    Ciconte G; Velagić V; Mugnai G; Saitoh Y; Irfan G; Hunuk B; Ströker E; Conte G; Sieira J; Di Giovanni G; Baltogiannis G; Brugada P; de Asmundis C; Chierchia GB
    Europace; 2016 Jan; 18(1):71-7. PubMed ID: 26445821
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of Ablation Index-Guided Ablation Results in High Rates of Durable Pulmonary Vein Isolation and Freedom From Arrhythmia in Persistent Atrial Fibrillation Patients: The PRAISE Study Results.
    Hussein A; Das M; Riva S; Morgan M; Ronayne C; Sahni A; Shaw M; Todd D; Hall M; Modi S; Natale A; Dello Russo A; Snowdon R; Gupta D
    Circ Arrhythm Electrophysiol; 2018 Sep; 11(9):e006576. PubMed ID: 30354288
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tailored ablation index based on left atrial wall thickness assessed by computed tomography for pulmonary vein isolation in patients with atrial fibrillation.
    Lee SR; Park HS; Kwon S; Choi EK; Oh S
    J Cardiovasc Electrophysiol; 2023 Sep; 34(9):1811-1819. PubMed ID: 37595097
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Efficacy of the optimal ablation index-targeted strategy for pulmonary vein isolation in patients with atrial fibrillation: the OPTIMUM study results.
    Lee SR; Choi EK; Lee EJ; Choe WS; Cha MJ; Oh S
    J Interv Card Electrophysiol; 2019 Aug; 55(2):171-181. PubMed ID: 31102113
    [TBL] [Abstract][Full Text] [Related]  

  • 12. EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation.
    Kautzner J; Neuzil P; Lambert H; Peichl P; Petru J; Cihak R; Skoda J; Wichterle D; Wissner E; Yulzari A; Kuck KH
    Europace; 2015 Aug; 17(8):1229-35. PubMed ID: 26041872
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Low contact force and force-time integral predict early recovery and dormant conduction revealed by adenosine after pulmonary vein isolation.
    le Polain de Waroux JB; Weerasooriya R; Anvardeen K; Barbraud C; Marchandise S; De Meester C; Goesaert C; Reis I; Scavee C
    Europace; 2015 Jun; 17(6):877-83. PubMed ID: 25618742
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical utility of automated ablation lesion tagging based on catheter stability information (VisiTag Module of the CARTO 3 System) with contact force-time integral during pulmonary vein isolation for atrial fibrillation.
    Okumura Y; Watanabe I; Iso K; Nagashima K; Sonoda K; Sasaki N; Kogawa R; Takahashi K; Ohkubo K; Nakai T; Nakahara S; Hori Y; Hirayama A
    J Interv Card Electrophysiol; 2016 Nov; 47(2):245-252. PubMed ID: 27278517
    [TBL] [Abstract][Full Text] [Related]  

  • 15. No association between dormant conduction sites and pulmonary vein reconnection sites in late atrial fibrillation recurrence after catheter ablation.
    Iso K; Watanabe I; Okumura Y; Nagashima K; Takahashi K; Kurokawa S; Arai M; Watanabe R; Wakamatsu Y; Ohkubo K; Nakai T; Hirayama A; Sonoda K; Tosaka T
    J Cardiol; 2018 Dec; 72(6):488-493. PubMed ID: 30318077
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Optimal Force-Time Integral for Pulmonary Vein Isolation According to Anatomical Wall Thickness Under the Ablation Line.
    Chikata A; Kato T; Sakagami S; Kato C; Saeki T; Kawai K; Takashima S; Murai H; Usui S; Furusho H; Kaneko S; Takamura M
    J Am Heart Assoc; 2016 Mar; 5(3):e003155. PubMed ID: 27068636
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The importance of catheter stability evaluated by Visitag(TM) during pulmonary vein isolation.
    Fujiwara R; Imamura K; Kijima Y; Masano T; Nagoshi R; Kohzuki A; Shibata H; Tsukiyama Y; Takeshige R; Yanaka K; Nakano S; Fukuyama Y; Shite J
    J Interv Card Electrophysiol; 2016 Aug; 46(2):161-6. PubMed ID: 26781786
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study.
    Neuzil P; Reddy VY; Kautzner J; Petru J; Wichterle D; Shah D; Lambert H; Yulzari A; Wissner E; Kuck KH
    Circ Arrhythm Electrophysiol; 2013 Apr; 6(2):327-33. PubMed ID: 23515263
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A multicentered evaluation of ablation at higher power guided by ablation index: Establishing ablation targets for pulmonary vein isolation.
    Dhillon G; Ahsan S; Honarbakhsh S; Lim W; Baca M; Graham A; Srinivasan N; Sawhney V; Sporton S; Schilling RJ; Chow A; Ginks M; Sohal M; Gallagher MM; Hunter RJ
    J Cardiovasc Electrophysiol; 2019 Mar; 30(3):357-365. PubMed ID: 30556609
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pulmonary vein reconnection following catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: results of a multicenter analysis.
    Aryana A; Singh SM; Mugnai G; de Asmundis C; Kowalski M; Pujara DK; Cohen AI; Singh SK; Fuenzalida CE; Prager N; Bowers MR; O'Neill PG; Brugada P; d'Avila A; Chierchia GB
    J Interv Card Electrophysiol; 2016 Dec; 47(3):341-348. PubMed ID: 27475949
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.