  • 1. Is modification of the VVI backup mode in implantable cardioverter-defibrillators from St Jude medical required due to increased risk of inappropriate shocks?
    Philbert BT; Tfelt-Hansen J; Jacobsen PK; Pehrson S; Svendsen JH; Jøns C; Petersen HH
    Europace; 2017 May; 19(5):808-811. PubMed ID: 27247013
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Performance of an ICD algorithm to detect lead noise and reduce inappropriate shocks.
    Beau S; Greer S; Ellis CR; Keeney J; Asopa S; Arnold E; Fischer A
    J Interv Card Electrophysiol; 2016 Mar; 45(2):225-32. PubMed ID: 26739482
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Survival after shock therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy-defibrillator recipients according to rhythm shocked. The ALTITUDE survival by rhythm study.
    Powell BD; Saxon LA; Boehmer JP; Day JD; Gilliam FR; Heidenreich PA; Jones PW; Rousseau MJ; Hayes DL
    J Am Coll Cardiol; 2013 Oct; 62(18):1674-1679. PubMed ID: 23810882
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure.
    Spencker S; Coban N; Koch L; Schirdewan A; Müller D
    Europace; 2009 Apr; 11(4):483-8. PubMed ID: 19103654
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reduced risk for inappropriate implantable cardioverter-defibrillator shocks with dual-chamber therapy compared with single-chamber therapy: results of the randomized OPTION study.
    Kolb C; Sturmer M; Sick P; Reif S; Davy JM; Molon G; Schwab JO; Mantovani G; Dan D; Lennerz C; Borri-Brunetto A; Babuty D
    JACC Heart Fail; 2014 Dec; 2(6):611-9. PubMed ID: 25282033
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Outcomes of defibrillator therapy in catecholaminergic polymorphic ventricular tachycardia.
    Roses-Noguer F; Jarman JW; Clague JR; Till J
    Heart Rhythm; 2014 Jan; 11(1):58-66. PubMed ID: 24120999
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A life-threatening arrhythmia induced by inappropriate activation of an implantable cardioverter defibrillator.
    Kadmon E; Kusniec J; Strasberg B
    Europace; 2009 Dec; 11(12):1716-8. PubMed ID: 19762330
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial.
    Wilkoff BL; Cook JR; Epstein AE; Greene HL; Hallstrom AP; Hsia H; Kutalek SP; Sharma A;
    JAMA; 2002 Dec; 288(24):3115-23. PubMed ID: 12495391
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Inappropriate discharges from an intravenous implantable cardioverter defibrillator due to T-wave oversensing.
    Washizuka T; Chinushi M; Kasai H; Watanabe H; Tagawa M; Hosaka Y; Abe A; Aizawa Y
    Jpn Circ J; 2001 Jul; 65(7):685-7. PubMed ID: 11446507
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Do current dual chamber cardioverter defibrillators have advantages over conventional single chamber cardioverter defibrillators in reducing inappropriate therapies? A randomized, prospective study.
    Deisenhofer I; Kolb C; Ndrepepa G; Schreieck J; Karch M; Schmieder S; Zrenner B; Schmitt C
    J Cardiovasc Electrophysiol; 2001 Feb; 12(2):134-42. PubMed ID: 11232608
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Electrical failure of an ICD lead due to a presumed insulation defect only diagnosed by a maximum output shock.
    Goldstein MA; Badri M; Kocovic D; Kowey PR
    Pacing Clin Electrophysiol; 2013 Sep; 36(9):1068-71. PubMed ID: 23731252
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Redetection of tachycardia in severe ventricular undersensing].
    Steffel J
    Herzschrittmacherther Elektrophysiol; 2016 Sep; 27(3):240-3. PubMed ID: 27459975
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Erroneous Magnet Positioning Leads to Failure of Inhibition of Inappropriate Shock during Fast Conducting Atrial Fibrillation Episodes.
    Römers H; VAN Dijk V; Balt J
    Pacing Clin Electrophysiol; 2017 Jun; 40(6):741-743. PubMed ID: 28326565
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Incidence and causes of inappropriate detection and therapy by implantable defibrillators of cardioversion in patients with ventricular tachyarrhythmia.
    Chen RH; Chen KP; Wang FZ; Hua W; Chen X; Zhang S
    Chin Med J (Engl); 2006 Apr; 119(7):557-63. PubMed ID: 16620696
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Implantable cardioverter-defibrillator oversensing due to electric shock].
    Jurcević R; Angelkov L; Vukajlović D; Ristić V; Tomović M; Djukanović B
    Srp Arh Celok Lek; 2010; 138(3-4):236-9. PubMed ID: 20499508
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Programming implantable cardioverter-defibrillators in primary prevention: higher or later.
    Clementy N; Pierre B; Simeon E; Lallemand B; Fauchier L; Babuty D
    Arch Cardiovasc Dis; 2014 May; 107(5):308-18. PubMed ID: 24834904
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial: rationale, design, results, clinical implications and lessons for future trials.
    Wilkoff BL;
    Card Electrophysiol Rev; 2003 Dec; 7(4):468-72. PubMed ID: 15071277
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Programming implantable cardioverter-defibrillator therapy zones to high ranges to prevent delivery of inappropriate device therapies in patients with primary prevention: results from the RISSY-ICD (Reduction of Inappropriate ShockS bY InCreaseD zones) trial.
    Cay S; Canpolat U; Ucar F; Ozeke O; Ozcan F; Topaloglu S; Aras D
    Am J Cardiol; 2015 May; 115(9):1235-43. PubMed ID: 25765588
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Inappropriate ICD shocks in pediatrics and congenital heart disease patients: Risk factors and programming strategies.
    Garnreiter JM; Pilcher TA; Etheridge SP; Saarel EV
    Heart Rhythm; 2015 May; 12(5):937-42. PubMed ID: 25620047
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spectrum of issues detected by an ICD diagnostic alert that utilizes far-field electrograms: Clinical implications.
    Koneru JN; Kaszala K; Bordachar P; Shehata M; Swerdlow C; Ellenbogen KA
    Heart Rhythm; 2015 May; 12(5):957-67. PubMed ID: 25640632
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]