214 related articles for article (PubMed ID: 27250693)
1. Usefulness of triphasic CT aortic angiography in acute and surveillance: Our experience in the assessment of acute aortic dissection and endoleak.
Reginelli A; Capasso R; Ciccone V; Croce MR; Di Grezia G; Carbone M; Maggialetti N; Barile A; Fonio P; Scialpi M; Brunese L
Int J Surg; 2016 Sep; 33 Suppl 1():S76-84. PubMed ID: 27250693
[TBL] [Abstract][Full Text] [Related]
2. There Is Limited Value in the One Month Post Endovascular Aortic Aneurysm Repair Surveillance Computed Tomography Scan.
Soult MC; Cheng BT; Mansukhani NA; Rodriguez HE; Eskandari MK; Hoel AW
Ann Vasc Surg; 2019 Jan; 54():27-32. PubMed ID: 30253190
[TBL] [Abstract][Full Text] [Related]
3. Contrast Enhanced Ultrasound can Replace Computed Tomography Angiography for Surveillance After Endovascular Aortic Aneurysm Repair.
Bredahl KK; Taudorf M; Lönn L; Vogt KC; Sillesen H; Eiberg JP
Eur J Vasc Endovasc Surg; 2016 Dec; 52(6):729-734. PubMed ID: 27760698
[TBL] [Abstract][Full Text] [Related]
4. Determination of Endograft Apposition, Position, and Expansion in the Aortic Neck Predicts Type Ia Endoleak and Migration After Endovascular Aneurysm Repair.
Schuurmann RCL; van Noort K; Overeem SP; van Veen R; Ouriel K; Jordan WD; Muhs BE; 't Mannetje YW; Reijnen MMPJ; Fioole B; Ünlü Ç; Brummel P; de Vries JPM
J Endovasc Ther; 2018 Jun; 25(3):366-375. PubMed ID: 29575993
[TBL] [Abstract][Full Text] [Related]
5. Outcomes and morphologic changes of immediate type Ia endoleak following endovascular repair of acute type B aortic dissection.
Huang W; Yang F; Luo J; Xie N; He P; Luo S; Liu Y; Zhou Y; Fan R; Huang M; Chen J
Ann Vasc Surg; 2015 Feb; 29(2):174-82. PubMed ID: 25463345
[TBL] [Abstract][Full Text] [Related]
6. Can we replace computed tomography angiography by contrast-enhanced ultrasound in the surveillance of patients submitted to aortoiliac aneurysm repair?
Park JH; Filho AR; Pires APM; Telles GJP; Esteves FP; Caffaro RA; Parrillo EF
Vascular; 2022 Aug; 30(4):803-808. PubMed ID: 34144651
[TBL] [Abstract][Full Text] [Related]
7. Dynamic, Time-Resolved Computed Tomography Angiography Technique to Characterize Aortic Endoleak Type, Inflow and Provide Guidance for Targeted Treatment.
Berczeli M; Lumsden AB; Chang SM; Bavare CS; Chinnadurai P
J Endovasc Ther; 2022 Feb; 29(1):11-22. PubMed ID: 34384284
[TBL] [Abstract][Full Text] [Related]
8. Dynamic Computed Tomography Angiography is More Accurate in Diagnosing Endoleaks than Standard Triphasic Computed Tomography Angiography and Enables Targeted Embolization.
Berczeli M; Chinnadurai P; Osztrogonácz P; Peden EK; Bavare CS; Sótonyi P; Chang SM; Lumsden AB
Ann Vasc Surg; 2023 Jan; 88():318-326. PubMed ID: 35817381
[TBL] [Abstract][Full Text] [Related]
9. Endovascular Aortic Repair Follow up Protocol Based on Contrast Enhanced Ultrasound Is Safe and Effective.
Chisci E; Harris L; Guidotti A; Pecchioli A; Pigozzi C; Barbanti E; Ercolini L; Michelagnoli S
Eur J Vasc Endovasc Surg; 2018 Jul; 56(1):40-47. PubMed ID: 29673811
[TBL] [Abstract][Full Text] [Related]
10. The Role of Duplex Ultrasound in Detecting Graft Thrombosis and Endoleak after Endovascular Aortic Repair for Abdominal Aneurysm.
Mazzaccaro D; Farina A; Petsos K; Nano G
Ann Vasc Surg; 2018 Oct; 52():22-29. PubMed ID: 29787854
[TBL] [Abstract][Full Text] [Related]
11. Changes in Apposition of Endograft Limbs in the Iliac Arteries After Endovascular Aneurysm Repair: Determination With New Computed Tomography-Applied Software.
Goudeketting SR; Schuurmann RCL; Slump CH; de Vries JPM
J Endovasc Ther; 2019 Dec; 26(6):843-852. PubMed ID: 31402731
[No Abstract] [Full Text] [Related]
12. Evaluating outcomes of endoleak discrepancies between computed tomography scan and ultrasound imaging after endovascular abdominal aneurysm repair.
Nagre SB; Taylor SM; Passman MA; Patterson MA; Combs BR; Lowman BG; Jordan WD
Ann Vasc Surg; 2011 Jan; 25(1):94-100. PubMed ID: 21172584
[TBL] [Abstract][Full Text] [Related]
13. Prospective nonrandomized study to evaluate cone beam computed tomography for technical assessment of standard and complex endovascular aortic repair.
Tenorio ER; Oderich GS; Sandri GA; Ozbek P; Kärkkäinen JM; Vrtiska T; Macedo TA; Gloviczki P
J Vasc Surg; 2020 Jun; 71(6):1982-1993.e5. PubMed ID: 31611108
[TBL] [Abstract][Full Text] [Related]
14. Duplex Ultrasound Surveillance After Uncomplicated Endovascular Abdominal Aortic Aneurysm Repair.
Schaeffer JS; Shakhnovich I; Sieck KN; Kallies KJ; Davis CA; Cogbill TH
Vasc Endovascular Surg; 2017 Jul; 51(5):295-300. PubMed ID: 28535732
[TBL] [Abstract][Full Text] [Related]
15. Prospective comparative analysis of colour-Doppler ultrasound, contrast-enhanced ultrasound, computed tomography and magnetic resonance in detecting endoleak after endovascular abdominal aortic aneurysm repair.
Cantisani V; Ricci P; Grazhdani H; Napoli A; Fanelli F; Catalano C; Galati G; D'Andrea V; Biancari F; Passariello R
Eur J Vasc Endovasc Surg; 2011 Feb; 41(2):186-92. PubMed ID: 21095141
[TBL] [Abstract][Full Text] [Related]
16. Spontaneous delayed sealing in selected patients with a primary type-Ia endoleak after endovascular aneurysm repair.
Bastos Gonçalves F; Verhagen HJ; Vasanthananthan K; Zandvoort HJ; Moll FL; van Herwaarden JA
Eur J Vasc Endovasc Surg; 2014 Jul; 48(1):53-9. PubMed ID: 24581938
[TBL] [Abstract][Full Text] [Related]
17. The value of the initial post-EVAR computed tomography angiography scan in predicting future secondary procedures using the Powerlink stent graft.
Patel MS; Carpenter JP
J Vasc Surg; 2010 Nov; 52(5):1135-9. PubMed ID: 20655690
[TBL] [Abstract][Full Text] [Related]
18. Management of Concealed Type IV Endoleak and Aortic Sac Hygroma by Prone ContrASt EnHancement Computed Tomography Angiography.
Sultan S; Acharya Y; Atteia E; Hynes N
Ann Vasc Surg; 2021 Apr; 72():647-661. PubMed ID: 33385530
[TBL] [Abstract][Full Text] [Related]
19. Predisposing Factors for Migration of the Iliac Limb and Reintervention after Endovascular Abdominal Aortic Aneurysm Repair.
Wang Y; Li C; Xin H; Li J; Wang H
Ann Vasc Surg; 2019 Aug; 59():91-101. PubMed ID: 31009727
[TBL] [Abstract][Full Text] [Related]
20. Contrast-enhanced ultrasound vs. CT angiography in fenestrated EVAR surveillance: a single-center comparison.
Perini P; Sediri I; Midulla M; Delsart P; Gautier C; Haulon S
J Endovasc Ther; 2012 Oct; 19(5):648-55. PubMed ID: 23046331
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]