These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
196 related articles for article (PubMed ID: 27258278)
21. New Method and Portable Measurement Device for the Calibration of Industrial Robots. Icli C; Stepanenko O; Bonev I Sensors (Basel); 2020 Oct; 20(20):. PubMed ID: 33092133 [TBL] [Abstract][Full Text] [Related]
22. A system for programming and controlling sensor-based robot manipulators. Geschke CC IEEE Trans Pattern Anal Mach Intell; 1983 Jan; 5(1):1-7. PubMed ID: 21869077 [TBL] [Abstract][Full Text] [Related]
23. Model Predictive Torque Control for Velocity Tracking of a Four-Wheeled Climbing Robot. Santos HB; Teixeira MAS; Dalmedico N; de Oliveira AS; Neves-Jr F; Ramos JE; de Arruda LVR Sensors (Basel); 2020 Dec; 20(24):. PubMed ID: 33321689 [TBL] [Abstract][Full Text] [Related]
24. A novel methodology to reproduce previously recorded six-degree of freedom kinematics on the same diarthrodial joint. Moore SM; Thomas M; Woo SL; Gabriel MT; Kilger R; Debski RE J Biomech; 2006; 39(10):1914-23. PubMed ID: 16005464 [TBL] [Abstract][Full Text] [Related]
25. Design and validation of an MR-conditional robot for transcranial focused ultrasound surgery in infants. Price KD; Sin VW; Mougenot C; Pichardo S; Looi T; Waspe AC; Drake JM Med Phys; 2016 Sep; 43(9):4983. PubMed ID: 27587029 [TBL] [Abstract][Full Text] [Related]
26. Peg-in-Hole Assembly Based on Two-phase Scheme and F/T Sensor for Dual-arm Robot. Zhang X; Zheng Y; Ota J; Huang Y Sensors (Basel); 2017 Sep; 17(9):. PubMed ID: 28862691 [TBL] [Abstract][Full Text] [Related]
27. Toward Development of Novel Remote Ultrasound Robotic System Using Soft Robotics Technology. Papendorp S; Ovando A; Gharaie S; Mosadegh B; Guerra-Zubiaga D; Alaie S; Ashuri T; Amiri Moghadam AA J Eng Sci Med Diagn Ther; 2024 May; 7(2):021012. PubMed ID: 38059170 [TBL] [Abstract][Full Text] [Related]
28. A Calibration Method for a Laser Triangulation Scanner Mounted on a Robot Arm for Surface Mapping. Idrobo-Pizo GA; Motta JMST; Sampaio RC Sensors (Basel); 2019 Apr; 19(8):. PubMed ID: 31013968 [TBL] [Abstract][Full Text] [Related]
29. Design and Calibration of Robot Base Force/Torque Sensors and Their Application to Non-Collocated Admittance Control for Automated Tool Changing. Gattringer H; Müller A; Hoermandinger P Sensors (Basel); 2021 Apr; 21(9):. PubMed ID: 33919041 [TBL] [Abstract][Full Text] [Related]
30. Fast Kinematic Re-Calibration for Industrial Robot Arms. Kana S; Gurnani J; Ramanathan V; Turlapati SH; Ariffin MZ; Campolo D Sensors (Basel); 2022 Mar; 22(6):. PubMed ID: 35336465 [TBL] [Abstract][Full Text] [Related]
31. MRI-Safe Robot for Endorectal Prostate Biopsy. Stoianovici D; Kim C; Srimathveeravalli G; Sebrecht P; Petrisor D; Coleman J; Solomon SB; Hricak H IEEE ASME Trans Mechatron; 2013 Sep; 19(4):1289-1299. PubMed ID: 25378897 [TBL] [Abstract][Full Text] [Related]
32. Delta Robot Kinematic Calibration for Precise Robot-Assisted Retinal Surgery. Xiao B; Alamdar A; Song K; Ebrahimi A; Gehlbach P; Taylor RH; Iordachita I Int Symp Med Robot; 2022 Apr; 2022():. PubMed ID: 36129421 [TBL] [Abstract][Full Text] [Related]
33. Improve the robot calibration accuracy using a dynamic online fuzzy error mapping system. Bai Y; Wang D IEEE Trans Syst Man Cybern B Cybern; 2004 Apr; 34(2):1155-60. PubMed ID: 15376860 [TBL] [Abstract][Full Text] [Related]
34. A Rapid Coordinate Transformation Method Applied in Industrial Robot Calibration Based on Characteristic Line Coincidence. Liu B; Zhang F; Qu X; Shi X Sensors (Basel); 2016 Feb; 16(2):239. PubMed ID: 26901203 [TBL] [Abstract][Full Text] [Related]
35. A force-sensing surgical tool with a proximally located force/torque sensor. Schwalb W; Shirinzadeh B; Smith J Int J Med Robot; 2017 Mar; 13(1):. PubMed ID: 26919028 [TBL] [Abstract][Full Text] [Related]
36. Instrumented Compliant Wrist with Proximity and Contact Sensing for Close Robot Interaction Control. Laferrière P; Payeur P Sensors (Basel); 2017 Jun; 17(6):. PubMed ID: 28613255 [TBL] [Abstract][Full Text] [Related]
37. Adaptive Kinematic Control of a Robotic Venipuncture Device Based on Stereo Vision, Ultrasound, and Force Guidance. Balter ML; Chen AI; Maguire TJ; Yarmush ML IEEE Trans Ind Electron; 2017 Feb; 64(2):1626-1635. PubMed ID: 28111492 [TBL] [Abstract][Full Text] [Related]