1160 related articles for article (PubMed ID: 27260458)
1. Microwave-assisted wet digestion with H2O2 at high temperature and pressure using single reaction chamber for elemental determination in milk powder by ICP-OES and ICP-MS.
Muller EI; Souza JP; Muller CC; Muller ALH; Mello PA; Bizzi CA
Talanta; 2016 Aug; 156-157():232-238. PubMed ID: 27260458
[TBL] [Abstract][Full Text] [Related]
2. Focused microwave-induced combustion for digestion of botanical samples and metals determination by ICP OES and ICP-MS.
Barin JS; Pereira JS; Mello PA; Knorr CL; Moraes DP; Mesko MF; Nóbrega JA; Korn MG; Flores EM
Talanta; 2012 May; 94():308-14. PubMed ID: 22608453
[TBL] [Abstract][Full Text] [Related]
3. Searching the most appropriate sample pretreatment for the elemental analysis of wines by inductively coupled plasma-based techniques.
Gonzálvez A; Armenta S; Pastor A; de la Guardia M
J Agric Food Chem; 2008 Jul; 56(13):4943-54. PubMed ID: 18553915
[TBL] [Abstract][Full Text] [Related]
4. Study and determination of elemental impurities by ICP-MS in active pharmaceutical ingredients using single reaction chamber digestion in compliance with USP requirements.
Muller AL; Oliveira JS; Mello PA; Muller EI; Flores EM
Talanta; 2015 May; 136():161-9. PubMed ID: 25702998
[TBL] [Abstract][Full Text] [Related]
5. Microwave-assisted digestion method using diluted nitric acid and hydrogen peroxide for the determination of major and minor elements in milk samples by ICP-OES and ICP-MS.
Lee J; Park YS; Lee HJ; Koo YE
Food Chem; 2022 Mar; 373(Pt B):131483. PubMed ID: 34782211
[TBL] [Abstract][Full Text] [Related]
6. Determination of elemental impurities in poly(vinyl chloride) by inductively coupled plasma optical emission spectrometry.
Pereira LS; Pedrotti MF; Miceli TM; Pereira JS; Flores EM
Talanta; 2016 May; 152():371-7. PubMed ID: 26992533
[TBL] [Abstract][Full Text] [Related]
7. Determination of Trace and Major Elements in Vegan Milk and Oils by ICP-OES After Microwave Digestion.
Karasakal A
Biol Trace Elem Res; 2020 Oct; 197(2):683-693. PubMed ID: 31898305
[TBL] [Abstract][Full Text] [Related]
8. Greening microwave-assisted digestion method using hydrogen peroxide for determination of elemental impurities by ICP-OES in antihypertensive active pharmaceutical ingredients.
Senger CM; Dornelles IS; Queiroz JM; Mello PA; Muller EI; Muller ALH
J Pharm Biomed Anal; 2024 Jan; 238():115802. PubMed ID: 37871418
[TBL] [Abstract][Full Text] [Related]
9. [Study on the determination of 28 inorganic elements in sunflower seeds by ICP-OES/ICP-MS].
Liu HW; Qin ZH; Xie HL; Cao S
Guang Pu Xue Yu Guang Pu Fen Xi; 2013 Jan; 33(1):224-7. PubMed ID: 23586261
[TBL] [Abstract][Full Text] [Related]
10. Low gas flow inductively coupled plasma optical emission spectrometry for the analysis of food samples after microwave digestion.
Nowak S; Gesell M; Holtkamp M; Scheffer A; Sperling M; Karst U; Buscher W
Talanta; 2014 Nov; 129():575-8. PubMed ID: 25127635
[TBL] [Abstract][Full Text] [Related]
11. Microwave-assisted UV digestion of starch and skimmed milk powder: Environmentally friendly protocol for essential and toxic elements determination.
Ramos do Nascimento V; Pereira de Almeida D; Giacobe K; Marlon de Moraes Flores E; Augusto Bizzi C
Talanta; 2024 Apr; 270():125575. PubMed ID: 38159353
[TBL] [Abstract][Full Text] [Related]
12. Determination of inorganic contaminants in carbon nanotubes by plasma-based techniques: Overcoming the limitations of sample preparation.
Krzyzaniak SR; Iop GD; Holkem AP; Flores EMM; Mello PA
Talanta; 2019 Jan; 192():255-262. PubMed ID: 30348387
[TBL] [Abstract][Full Text] [Related]
13. Optimization and validation of a fast digestion method for the determination of major and trace elements in breast milk by ICP-MS.
Astolfi ML; Marconi E; Protano C; Vitali M; Schiavi E; Mastromarino P; Canepari S
Anal Chim Acta; 2018 Dec; 1040():49-62. PubMed ID: 30327113
[TBL] [Abstract][Full Text] [Related]
14. The combination of infrared and microwave radiation to quantify trace elements in organic samples by ICP OES.
Dantas AN; Matos WO; Gouveia ST; Lopes GS
Talanta; 2013 Mar; 107():292-6. PubMed ID: 23598225
[TBL] [Abstract][Full Text] [Related]
15. Major and trace elemental analysis in milk powder by inductively coupled plasma-optical emission spectrometry (ICP-OES) and instrumental neutron activation analysis (INAA).
Sroor A; el-Dine NW; el-Shershaby A; Abdel-Haleem AS
J Environ Sci (China); 2003 Jul; 15(4):570-6. PubMed ID: 12974322
[TBL] [Abstract][Full Text] [Related]
16. Multi-element determination in acid-digested soy protein formulations by inductively coupled plasma-optical emission spectrometry.
Morte ES; Costa LM; Nobrega JA; Korn Md
Food Addit Contam Part A Chem Anal Control Expo Risk Assess; 2008 May; 25(5):616-21. PubMed ID: 18473216
[TBL] [Abstract][Full Text] [Related]
17. Multivariate Optimization of Conditions for Digestion of Wet Feeds for Dogs and Cats Using a Closed Digester Block and Multielement Determination by ICP-OES.
Ávila DVL; Souza SO; Costa SSL; Garcia CAB; Alves JDPH; Araujo RGO; Passos EA
J AOAC Int; 2017 Sep; 100(5):1483-1491. PubMed ID: 28734042
[TBL] [Abstract][Full Text] [Related]
18. Effect of simultaneous cooling on microwave-assisted wet digestion of biological samples with diluted nitric acid and O2 pressure.
Bizzi CA; Nóbrega JA; Barin JS; Oliveira JS; Schmidt L; Mello PA; Flores EM
Anal Chim Acta; 2014 Jul; 837():16-22. PubMed ID: 25000853
[TBL] [Abstract][Full Text] [Related]
19. Microwave-assisted digestion of organic samples: how simple can it become?
Nóbrega JA; Pirola C; Fialho LL; Rota G; de Campos Jordão CE; Pollo F
Talanta; 2012 Aug; 98():272-6. PubMed ID: 22939159
[TBL] [Abstract][Full Text] [Related]
20. Alkali dilution of blood samples for high throughput ICP-MS analysis-comparison with acid digestion.
Lu Y; Kippler M; Harari F; Grandér M; Palm B; Nordqvist H; Vahter M
Clin Biochem; 2015 Feb; 48(3):140-7. PubMed ID: 25498303
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]