These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 27268387)

  • 41. A fluoro-microbead guiding chip for simple and quantifiable immunoassay of cardiac troponin I (cTnI).
    Song SY; Han YD; Kim K; Yang SS; Yoon HC
    Biosens Bioelectron; 2011 May; 26(9):3818-24. PubMed ID: 21439810
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Multiplex Label-Free Kinetic Characterization of Antibodies for Rapid Sensitive Cardiac Troponin I Detection Based on Functionalized Magnetic Nanotags.
    Orlov AV; Malkerov JA; Novichikhin DO; Znoyko SL; Nikitin PI
    Int J Mol Sci; 2022 Apr; 23(9):. PubMed ID: 35562865
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Electrochemical nanobiosensor for express diagnosis of acute myocardial infarction in undiluted plasma.
    Suprun E; Bulko T; Lisitsa A; Gnedenko O; Ivanov A; Shumyantseva V; Archakov A
    Biosens Bioelectron; 2010 Mar; 25(7):1694-8. PubMed ID: 20060282
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Autonomous capillary microfluidic system with embedded optics for improved troponin I cardiac biomarker detection.
    Mohammed MI; Desmulliez MP
    Biosens Bioelectron; 2014 Nov; 61():478-84. PubMed ID: 24934750
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Lab-on-a-disc for fully integrated multiplex immunoassays.
    Park J; Sunkara V; Kim TH; Hwang H; Cho YK
    Anal Chem; 2012 Mar; 84(5):2133-40. PubMed ID: 22277086
    [TBL] [Abstract][Full Text] [Related]  

  • 46. A rapid, direct, quantitative, and label-free detector of cardiac biomarker troponin T using near-infrared fluorescent single-walled carbon nanotube sensors.
    Zhang J; Kruss S; Hilmer AJ; Shimizu S; Schmois Z; De La Cruz F; Barone PW; Reuel NF; Heller DA; Strano MS
    Adv Healthc Mater; 2014 Mar; 3(3):412-23. PubMed ID: 23966175
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Proteomic biomarkers for diagnosis in acute myocardial infarction.
    Park JP; Park MK; Yun JW
    Biomarkers; 2011 Feb; 16(1):1-11. PubMed ID: 20923274
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Evaluation of a modified lateral flow immunoassay for detection of high-sensitivity cardiac troponin I and myoglobin.
    Zhu J; Zou N; Mao H; Wang P; Zhu D; Ji H; Cong H; Sun C; Wang H; Zhang F; Qian J; Jin Q; Zhao J
    Biosens Bioelectron; 2013 Apr; 42():522-5. PubMed ID: 23247055
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Detection of protein biomarker using a blood glucose meter.
    Lan T; Xiang Y; Lu Y
    Methods Mol Biol; 2015; 1256():99-109. PubMed ID: 25626534
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Aptamer-antibody on-chip sandwich immunoassay for detection of CRP in spiked serum.
    Pultar J; Sauer U; Domnanich P; Preininger C
    Biosens Bioelectron; 2009 Jan; 24(5):1456-61. PubMed ID: 18951012
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Microparticle-based platform for point-of-care immunoassays.
    Salminen T; Juntunen E; Lahdenranta M; Martiskainen I; Talha SM; Pettersson K
    Anal Biochem; 2018 May; 548():66-68. PubMed ID: 29486205
    [TBL] [Abstract][Full Text] [Related]  

  • 52. SERS-based competitive immunoassay of troponin I and CK-MB markers for early diagnosis of acute myocardial infarction.
    Chon H; Lee S; Yoon SY; Lee EK; Chang SI; Choo J
    Chem Commun (Camb); 2014 Feb; 50(9):1058-60. PubMed ID: 24310060
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Incorporating Aptamers in the Multiple Analyte Profiling Assays (xMAP): Detection of C-Reactive Protein.
    Bernard ED; Nguyen KC; DeRosa MC; Tayabali AF; Aranda-Rodriguez R
    Methods Mol Biol; 2017; 1575():303-322. PubMed ID: 28255889
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Effects of contemporary troponin assay sensitivity on the utility of the early markers myoglobin and CKMB isoforms in evaluating patients with possible acute myocardial infarction.
    Kavsak PA; MacRae AR; Newman AM; Lustig V; Palomaki GE; Ko DT; Tu JV; Jaffe AS
    Clin Chim Acta; 2007 May; 380(1-2):213-6. PubMed ID: 17306781
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Can a Point-of-Care Troponin I Assay be as Good as a Central Laboratory Assay? A MIDAS Investigation.
    Peacock WF; Diercks D; Birkhahn R; Singer AJ; Hollander JE; Nowak R; Safdar B; Miller CD; Peberdy M; Counselman F; Chandra A; Kosowsky J; Neuenschwander J; Schrock J; Lee-Lewandrowski E; Arnold W; Nagurney J
    Ann Lab Med; 2016 Sep; 36(5):405-12. PubMed ID: 27374704
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Ultrasensitive, label-free detection of cardiac biomarkers with optical SIS sensor.
    Diware MS; Cho HM; Chegal W; Cho YJ; Kim DS; O SW; Kim KS; Paek SH
    Biosens Bioelectron; 2017 Jan; 87():242-248. PubMed ID: 27567249
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Evaluation of a point-of-care test for canine C-reactive protein.
    Plickert HD; Einspanier R; Arndt G; Brunnberg L; Kohn B
    Vet Clin Pathol; 2011 Sep; 40(3):384-8. PubMed ID: 21827518
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Porous graphene oxide nanostructure as an excellent scaffold for label-free electrochemical biosensor: Detection of cardiac troponin I.
    Kazemi SH; Ghodsi E; Abdollahi S; Nadri S
    Mater Sci Eng C Mater Biol Appl; 2016 Dec; 69():447-52. PubMed ID: 27612734
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Recent advances in cardiac biomarkers detection: From commercial devices to emerging technologies.
    Savonnet M; Rolland T; Cubizolles M; Roupioz Y; Buhot A
    J Pharm Biomed Anal; 2021 Feb; 194():113777. PubMed ID: 33293175
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Detection of cardiac biomarkers using micellar electrokinetic chromatography and a cleavable tag immunoassay.
    Caulum MM; Murphy BM; Ramsay LM; Henry CS
    Anal Chem; 2007 Jul; 79(14):5249-56. PubMed ID: 17566984
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.